Common use of Interconnection Customer’s Interconnection Facilities Clause in Contracts

Interconnection Customer’s Interconnection Facilities. The Interconnection Customer constructed the Interconnection Customer’s Interconnection Facilities in accordance with the applicable requirements of Connecting Transmission Owner, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT, and in accordance with the Connecting Transmission Owner’s project specific electrical requirements, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT. As depicted in Attachment 3, Figures 1 and 2, the Interconnection Customer Interconnection Facilities consist of:  The Collection Station (Jointly Owned Interconnection Facilities), including:  One (1) 13.8 kV, 2500 A bus tie breaker;  Relaying;  One (1) 3Ph, 75 kVA 13800/480-277V station service transformer;  Six (6) 115 kV surge arresters;  Two (2) 25/33/41.6 MVA 115/13.8Y kV transformers;  Two (2) 13.8 kV, 2500 A breakers;  Two (2) 115 kV, 1200A, 550 kV BIL oil circuit breakers;  Two (2) 115 kV, 1200A motor operated, oil circuit breaker disconnect switches;  Two (2) 115 kV, 1200 A, motor operated line disconnect switches; and  Two (2) 115 kV, 1200 A, motor operated tie disconnect switches.  Equipment in Switchgear, including, but not limited to:  Two (2) 13.8 kV, 1200 A feeder breaker;  Six (6) 12 kV station class surge arresters;

Appears in 6 contracts

Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement

AutoNDA by SimpleDocs

Interconnection Customer’s Interconnection Facilities. The Interconnection Customer constructed the Interconnection Customer’s Interconnection Facilities in accordance with the applicable requirements of Connecting Transmission Owner, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT, and in accordance with the Connecting Transmission Owner’s project specific electrical requirements, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT. As depicted in Attachment 3, Figures 1 and 2, the Interconnection Customer Interconnection Facilities consist of: The Collection Station (Jointly Owned Interconnection Facilities), including: One (1) 13.8 kV, 2500 A bus tie breaker; Relaying; One (1) 3Ph, 75 kVA 13800/480-277V station service transformer; Six (6) 115 kV surge arresters; Two (2) 25/33/41.6 MVA 115/13.8Y kV transformers; Two (2) 13.8 kV, 2500 A breakers; Two (2) 115 kV, 1200A, 550 kV BIL oil circuit breakers; Two (2) 115 kV, 1200A motor operated, oil circuit breaker disconnect switches; Two (2) 115 kV, 1200 A, motor operated line disconnect switches; and Two (2) 115 kV, 1200 A, motor operated tie disconnect switches. Equipment in Switchgear, including, but not limited to: Two (2) 13.8 kV, 1200 A feeder breaker; Six (6) 12 kV station class surge arresters;

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.