Acceptance Test Procedures. Seller acknowledges that: (aa) Company has multiple on-going projects with other developers as well as its own capital improvement projects; (bb) Company has limited resources to provide engineering oversight (such as review of plans) to such projects and to participate in the testing of such projects; (cc) in order for Company to accommodate such oversight and testing, it is necessary for Company to sequentially allocate its resources for each project a year or more in advance; (dd) the result is a queue of such projects that reflects the scheduling commitments of Company's resources to conduct such oversight and to participate in such testing; (ee) if a project is behind the schedule on which Company's resources have been scheduled for the oversight of such project, or if a project is not ready for testing at the time Company's resources have been scheduled for the testing of such project, or if a project does not complete testing within the period for which Company's resources have been scheduled for such testing, the progress of projects later in the queue may be adversely affected; (ff) the Test Ready Deadline that is set forth in Attachment K-1 (Seller's Conditions Precedent and Company Milestones) reflects the scheduling commitment of Company's resources to (i) conduct the oversight necessary to facilitate Seller's achievement of that Test Ready Deadline, (ii) commence the Acceptance Test on the Acceptance Testing Milestone Date that is set forth in Attachment K-1 (Seller's Conditions Precedent and Company Milestones) and (iii) thereafter participate in the Control System Acceptance Test; and (gg) the Project will lose its place in the queue and will be assigned a new Acceptance Testing Milestone Date for commencement of the Acceptance Test that will be behind the other projects then in the queue if (i) the Seller fails to satisfy any of the conditions precedent set forth in Section f(ii) of this Attachment G (Company-Owned Interconnection Facilities) within the time period specified therein for the task in question or, if no time period is specified therein, by the Test Ready Deadline, (ii) the Seller fails to satisfy any of the Seller's Conditions Precedent set forth in Attachment K-1 (Seller's Conditions Precedent and Company Milestones) and/or (iii) the Acceptance Test and the Control System Acceptance Test are not satisfactorily completed within the time allotted to complete such testing. The Conduct of the Acceptance Test is subject to the sat...
Acceptance Test Procedures. The following conditions precedent must be satisfied prior to the conduct of the Acceptance Test: Final Single-Line Drawing, and notes, has received Company's written consent pursuant to Section 1(a)(i) (Single Line Drawing, Interface Block Diagram, Relay List, Relay Settings and Trip Scheme) of Attachment B (Facility Owned by Seller) to this Agreement. Final Relay List and Trip Scheme have received Company's written consent pursuant to Section 1(a)(i) of Attachment B (Facility Owned by Seller) to this Agreement. Final Interface Block Diagram has received Company consent pursuant to Section 1(a)(i) of Attachment B (Facility Owned by Seller) to this Agreement. Final Control System RTU Points List has received Company consent. Final digital fault recorder settings have received Company consent. No later than 14 Days prior to commencement of the Acceptance Test: •• Seller shall have certified to Company that Seller-Owned Interconnection Facilities have been installed and commissioned and such certification has not, prior to the commencement of the Acceptance Test, been subsequently challenged by Company on the basis of on-site observations made by the Company's representatives following the walk-through to be conducted pursuant to Section 2(f)(ii) of this Attachment G (Company-Owned Interconnection Facilities). •• Seller shall have certified to Company that any Company-Owned Interconnection Facilities built by Seller (and/or its Contractors) have been installed and commissioned and such certification has not, prior to the commencement of the Acceptance Test, been subsequently challenged by Company on the basis of on-site observations made by the Company's representatives following the walk-through to be conducted pursuant to Section 2(f)(ii) of this Attachment G (Company-Owned Interconnection Facilities). Any Company-Owned Interconnection Facilities not built by or on behalf of Seller have been installed and commissioned. No later than 7 Days prior to the commencement of the Acceptance Test, Seller and Company shall have participated in walk-through of fully constructed Interconnection Facilities. Redlined as-built drawings of the Seller-Owned Interconnection Facilities and any of the Company-Owned Interconnection Facilities built by Seller (and/or its Contractors) shall have been provided to Company. Continuous power is being supplied to Company's protection and SCADA equipment. Not less than four (4) weeks prior to the commencement of the Acceptance Test, t...
Acceptance Test Procedures. 5. AFFILIATE....
Acceptance Test Procedures. Novatel shall inspect and test all Guaranteed Volume Modem deliveries prior to shipment to confirm conformance with the Specifications. Following receipt of delivery of a Modem shipment, Metricom or its Designee(s), as specified in the applicable purchase order, may inspect such shipment for conformance with the Specifications.
(a) Upon determination that a shipment does meet Specifications, Metricom will issue an Acceptance Certificate for such shipment. Such Acceptance Certificate does not imply acceptance of any other shipment nor waive the warranty provisions under this Agreement or any other remedy that Metricom may have for a defective shipment.
(b) In the event that a shipment is rejected for failure to meet Specifications, Metricom or its Designee(s) shall return the shipment at Novatels expense and provide Novatel with written notification of the shipment's nonconformity. Novatel shall undertake to repair or replace the shipment or any nonconforming portion thereof at no charge to Metricom. or its Designee(s) and resubmit the shipment to Metricom or its Designee(s) within five (5) days of receipt of the rejected shipment.
Acceptance Test Procedures. (a) Seller shall prepare and submit to Buyer for approval Acceptance Test Procedures ("ATP").
(b) ATP shall define comprehensive and sufficient tests to prove and demonstrate that items passing the test meet all the requirements of the Product Specifications.
(c) ATP shall define, among other things, the tests, signals inputs and outputs, nominal values and tolerances, and the procedure where test sequence is significant. Test equipment configuration, test set-up, accuracy, loading and other arrangements shall be defined for these tests.
Acceptance Test Procedures. 2.1. The SERVICE PROVIDER shall, during the Acceptance Test Period, make available the Ordered Software Application Solutions to the CUSTOMER (including any products supplied by the SERVICE PROVIDER necessary to enable the provision of those Ordered Software Application Solutions) for the Acceptance Procedures to be performed.
2.2. The CUSTOMER will conduct Acceptance Tests on the Ordered Software Application Solution to test whether they meet the Acceptance Test Criteria, in the relevant Sprint, or User Story.
2.3. In respect of a Sprint or User Story, the Acceptance Procedures shall be recorded as successful and the SERVICE PROVIDER notified accordingly where the Acceptance Test Criteria are met. In respect of a Major Release the Acceptance Procedures shall be recorded as successful and the SERVICE PROVIDER notified accordingly where the Acceptance Test Criteria are met. For each Major Release the Production Quality Criteria must be met by the end of the relevant Warranty Period.
2.4. The Acceptance Procedures shall be recorded as unsuccessful and the SERVICE PROVIDER notified accordingly where any of the Acceptance Test Criteria are not met.
2.5. In the event that the Acceptance Procedure in respect of each Sprint or User Story has not been recorded as successful the rejected User Story shall become a Remedial Story and dealt with in accordance with paragraph 8 of Schedule 2-3.
2.6. In the event that the Acceptance Procedure in respect of each Major Release has not been recorded as successful by the end of the relevant Acceptance Test Period the CUSTOMER shall extend the relevant Acceptance Test Period by a period of 10 Working Days (or such other period as the parties may agree) during which time the SERVICE PROVIDER shall correct the faults which caused the Acceptance Procedures to be recorded as unsuccessful and the Acceptance Procedures shall be re- performed.
2.7. In the event that after the CUSTOMER has extended the Acceptance Test Procedure pursuant to paragraph 2.6 of this Schedule 2-5, the relevant Acceptance Procedures have not been recorded as successful by the end of that period, the CUSTOMER shall, without prejudice to its other rights and remedies, be entitled to:-
2.7.1. extend the Acceptance Text Period for a further period (or periods) specified by the CUSTOMER during which the SERVICE PROVIDER shall correct the faults which caused the Acceptance Procedures to be recorded as unsuccessful and the Acceptance Procedure shall be re-performe...
Acceptance Test Procedures. Within fifteen (15) days after contract award, and before beginning production, the contractor shall propose acceptance test procedures for Government approval. The procedures shall be updated by the Contractor as changes to the baseline system occur. ATTACHMENT 1 — ISURRS SOW 18 December 2002 M67854-03-R-1012
Acceptance Test Procedures. All Deliverables and physical or digital products delivered by Contractor under this Contract shall comply with final Acceptance testing
Acceptance Test Procedures. Contractor shall develop detailed Acceptance Test procedures in accordance with Exhibit I-1 and shall provide such procedures to Owner for Owner’s review and approval not less than one hundred twenty (120) days prior to the date on which Contractor anticipates the commencement of the testing of Unit 1.
Acceptance Test Procedures. This document specifies the acceptance tests, which will be performed by the ITA and the manner in which such tests will be accomplished and documented on a fiber optic cable system installed by the City. Optical reflectivity of the cable system will be measured using an Optical Time Domain Reflectometer (OTDR). Measurements will be accomplished from both ends of the cable system. A sufficient length of launch cable will be used for all OTDR testing to allow all data from the cable under tests to be visible on the OTDT trace display. The OTDR traces will be recorded at 1330 nm and 1550 nm operating wavelengths to verify the cable system is specified for service. The OTDR measurements can provide the following information of the quality of the installed fiber system: