{"component": "clause", "props": {"groups": [{"snippet_links": [{"key": "in-addition-to-the", "type": "clause", "offset": [0, 18]}, {"key": "building-generator", "type": "clause", "offset": [19, 37]}, {"key": "landlord-shall", "type": "clause", "offset": [79, 93]}, {"key": "at-tenant", "type": "definition", "offset": [133, 142]}, {"key": "cost-and-expense", "type": "clause", "offset": [150, 166]}, {"key": "natural-gas", "type": "definition", "offset": [201, 212]}, {"key": "by-landlord", "type": "clause", "offset": [267, 278]}, {"key": "compliance-with-all-applicable-laws", "type": "clause", "offset": [291, 326]}, {"key": "prior-written-approval", "type": "clause", "offset": [342, 364]}, {"key": "all-plans", "type": "clause", "offset": [368, 377]}, {"key": "receipt-of", "type": "clause", "offset": [462, 472]}, {"key": "governmental-permits-and-approvals", "type": "clause", "offset": [488, 522]}, {"key": "tenant-shall", "type": "clause", "offset": [524, 536]}, {"key": "the-specifications", "type": "definition", "offset": [544, 562]}, {"key": "maintenance-of-the", "type": "clause", "offset": [603, 621]}, {"key": "for-landlord", "type": "definition", "offset": [639, 651]}, {"key": "be-conditioned", "type": "clause", "offset": [731, 745]}, {"key": "complying-with", "type": "clause", "offset": [756, 770]}, {"key": "based-on", "type": "definition", "offset": [821, 829]}, {"key": "systems-and-equipment", "type": "definition", "offset": [914, 935]}, {"key": "adversely-affected", "type": "definition", "offset": [944, 962]}, {"key": "no-obligation-to-provide", "type": "clause", "offset": [984, 1008]}, {"key": "without-limitation", "type": "clause", "offset": [1033, 1051]}, {"key": "electric-current", "type": "clause", "offset": [1053, 1069]}, {"key": "gas-service", "type": "definition", "offset": [1073, 1084]}, {"key": "subject-to-applicable-laws", "type": "clause", "offset": [1130, 1156]}, {"key": "approval-of-plans-and-specifications", "type": "clause", "offset": [1186, 1222]}, {"key": "tenant-may", "type": "definition", "offset": [1233, 1243]}, {"key": "maintain-and-operate", "type": "clause", "offset": [1258, 1278]}, {"key": "utility-connections", "type": "clause", "offset": [1289, 1308]}, {"key": "the-premises", "type": "clause", "offset": [1342, 1354]}, {"key": "generator-facilities", "type": "definition", "offset": [1417, 1437]}, {"key": "pay-for", "type": "definition", "offset": [1579, 1586]}, {"key": "in-accordance-with", "type": "clause", "offset": [1642, 1660]}, {"key": "sole-and-absolute-discretion", "type": "definition", "offset": [1707, 1735]}, {"key": "performed-by-tenant", "type": "clause", "offset": [1891, 1910]}, {"key": "reasonable-period", "type": "definition", "offset": [1920, 1937]}, {"key": "reasonable-time", "type": "clause", "offset": [1986, 2001]}, {"key": "efforts-to-obtain", "type": "clause", "offset": [2109, 2126]}, {"key": "promptly-commence", "type": "clause", "offset": [2143, 2160]}, {"key": "line-of", "type": "definition", "offset": [2281, 2288]}, {"key": "responsible-for", "type": "clause", "offset": [2318, 2333]}, {"key": "cost-of", "type": "clause", "offset": [2338, 2345]}, {"key": "good-order", "type": "definition", "offset": [2396, 2406]}, {"key": "condition-and-repair", "type": "clause", "offset": [2408, 2428]}, {"key": "in-compliance-with-applicable-laws", "type": "clause", "offset": [2433, 2467]}, {"key": "damage-to-the-building", "type": "clause", "offset": [2502, 2524]}, {"key": "necessary-improvements", "type": "clause", "offset": [2545, 2567]}, {"key": "caused-by", "type": "clause", "offset": [2585, 2594]}, {"key": "the-installation", "type": "clause", "offset": [2613, 2629]}, {"key": "removal-of", "type": "clause", "offset": [2650, 2660]}, {"key": "no-warranties-or-representations", "type": "clause", "offset": [2698, 2730]}, {"key": "to-tenant", "type": "definition", "offset": [2731, 2740]}, {"key": "the-designated", "type": "definition", "offset": [2766, 2780]}, {"key": "generator-location", "type": "definition", "offset": [2781, 2799]}, {"key": "operation-of-the", "type": "clause", "offset": [2825, 2841]}, {"key": "if-tenant", "type": "clause", "offset": [2860, 2869]}, {"key": "at-the-time", "type": "definition", "offset": [2897, 2908]}, {"key": "of-landlord", "type": "clause", "offset": [2909, 2920]}, {"key": "ups-systems", "type": "definition", "offset": [3104, 3115]}, {"key": "termination-of-the-term", "type": "clause", "offset": [3148, 3171]}, {"key": "damage-to-the-project", "type": "clause", "offset": [3187, 3208]}, {"key": "resulting-from", "type": "definition", "offset": [3209, 3223]}, {"key": "associated-facilities", "type": "definition", "offset": [3284, 3305]}, {"key": "article-14", "type": "definition", "offset": [3367, 3377]}, {"key": "the-tenant", "type": "clause", "offset": [3525, 3535]}, {"key": "regular-maintenance", "type": "definition", "offset": [3599, 3618]}, {"key": "period-of", "type": "clause", "offset": [3633, 3642]}, {"key": "power-outage", "type": "definition", "offset": [3654, 3666]}, {"key": "to-operate", "type": "definition", "offset": [3708, 3718]}, {"key": "notice-to-landlord", "type": "clause", "offset": [3787, 3805]}, {"key": "approved-by", "type": "definition", "offset": [3830, 3841]}, {"key": "use-and-operation", "type": "clause", "offset": [3916, 3933]}, {"key": "use-of-the-project", "type": "clause", "offset": [3987, 4005]}, {"key": "other-tenants", "type": "clause", "offset": [4009, 4022]}], "size": 11, "samples": [{"hash": "8Vw1gUV2iH", "uri": "/contracts/8Vw1gUV2iH#backup-generator", "label": "Lease Agreement (Generate Biomedicines, Inc.)", "score": 37.0930862427, "published": true}, {"hash": "k9KHji1KV7", "uri": "/contracts/k9KHji1KV7#backup-generator", "label": "Lease Agreement (Generate Biomedicines, Inc.)", "score": 36.9753608704, "published": true}], "snippet": "In addition to the Building Generator and UPS System (as hereinafter defined), Landlord shall permit Tenant to install and maintain, at Tenant\u2019s sole cost and expense, up to a 500 kW, backup diesel or natural gas powered emergency generator2 at a location designated by Landlord, subject to compliance with all applicable Laws and Landlord\u2019s prior written approval of all plans and specifications, which approval shall not be unreasonably withheld, and Tenant\u2019s receipt of any applicable governmental permits and approvals. Tenant shall submit the specifications for design, operation, installation and maintenance of the backup generator for Landlord\u2019s consent, which consent shall not be unreasonably withheld or delayed and may be conditioned on Tenant complying with such reasonable requirements imposed by Landlord, based on the advice of \u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2019s structural and mechanical engineers, so that the Project\u2019s systems and equipment are not adversely affected. Landlord shall have no obligation to provide any services including, without limitation, electric current or gas service, to the backup generator, provided, however, subject to applicable Laws and Landlord\u2019s prior written approval of plans and specifications therefor, Tenant may also install, maintain and operate necessary utility connections between the backup generator and the Premises (which utility connections shall be deemed part of the backup generator facilities). Tenant shall connect the backup generator and the Building Generator and UPS System to the electrical submeter(s) serving the Premises and pay for the electricity supplied to such systems and equipment in accordance with Section 11(a)(ii) below. Landlord may, in its sole and absolute discretion, require Tenant, at Landlord\u2019s cost, to relocate any or all of the backup generator to a location with comparable functionality, which relocation shall be performed by Tenant within a reasonable period following such request (taking into account any reasonable time necessary to obtain permits and approvals for such work, Tenant hereby agreeing to use diligent good faith efforts to obtain the same and to promptly commence and prosecute to completion such relocation thereafter). The vent for the backup generator must be higher than the roof line of the Project. Tenant shall be responsible for the cost of repairing and maintaining the backup generator in good order, condition and repair and in compliance with applicable Laws and for the cost of repairing any damage to the Building, or the cost of any necessary improvements to the Building, caused by or as a result of the installation, replacement and/or removal of the backup generator. Landlord makes no warranties or representations to Tenant as to the suitability of the designated generator location for the installation and operation of the backup generator. If Tenant is so notified by Landlord at the time of Landlord\u2019s approval of the specifications for the backup generator, Tenant shall, at Tenant\u2019s sole cost and expense, remove such Tenant installed generator (but not the Building Generator and UPS Systems) upon the expiration or earlier termination of the Term and repair all damage to the Project resulting from such removal. Any Tenant installed backup generator and all associated facilities shall be deemed to be a part of the Premises for purposes of Article 14 of this Lease. The Building Generator and any Tenant installed backup generator may be referred to herein collectively as the \u201cTenant Generators.\u201d The Tenant Generators shall be used by Tenant only during (i) testing and regular maintenance, and (ii) any period of electrical power outage in the Project. Tenant shall be entitled to operate the Tenant Generators for testing and regular maintenance only upon notice to Landlord and at times reasonably approved by Landlord. Further, Tenant shall be responsible for ensuring that Tenant\u2019s use and operation of the Tenant Generators does not interfere with the use of the Project by other tenants.", "hash": "54cd984878d4bfad502479ea661dcde6", "id": 1}, {"snippet_links": [{"key": "tenant-to-maintain", "type": "clause", "offset": [0, 18]}, {"key": "condition-and-repair", "type": "clause", "offset": [37, 57]}, {"key": "required-replacements", "type": "definition", "offset": [73, 94]}, {"key": "at-tenant", "type": "definition", "offset": [97, 106]}, {"key": "cost-and-expense", "type": "clause", "offset": [114, 130]}, {"key": "equipment-and-infrastructure", "type": "definition", "offset": [212, 240]}, {"key": "maintenance-and", "type": "clause", "offset": [283, 298]}, {"key": "the-generator", "type": "clause", "offset": [315, 328]}, {"key": "subject-to", "type": "clause", "offset": [338, 348]}, {"key": "all-applicable-laws", "type": "clause", "offset": [349, 368]}, {"key": "terms-and-conditions", "type": "clause", "offset": [378, 398]}, {"key": "by-landlord", "type": "clause", "offset": [428, 439]}, {"key": "landlord-shall", "type": "clause", "offset": [465, 479]}, {"key": "in-connection-with", "type": "clause", "offset": [518, 536]}, {"key": "without-limiting-the-generality-of-the-foregoing", "type": "clause", "offset": [547, 595]}, {"key": "tenant-shall", "type": "clause", "offset": [597, 609]}, {"key": "municipal-permits", "type": "clause", "offset": [700, 717]}, {"key": "licenses-and-approvals", "type": "clause", "offset": [719, 741]}, {"key": "including-without-limitation", "type": "clause", "offset": [743, 771]}, {"key": "bay-area-air-quality-management-district", "type": "definition", "offset": [822, 862]}, {"key": "by-tenant", "type": "clause", "offset": [943, 952]}, {"key": "regular-maintenance", "type": "definition", "offset": [981, 1000]}, {"key": "period-of", "type": "clause", "offset": [1014, 1023]}, {"key": "power-outage", "type": "definition", "offset": [1035, 1047]}, {"key": "to-operate", "type": "definition", "offset": [1089, 1099]}, {"key": "notice-to-landlord", "type": "clause", "offset": [1160, 1178]}, {"key": "approved-by", "type": "definition", "offset": [1203, 1214]}, {"key": "hazardous-materials", "type": "definition", "offset": [1294, 1313]}, {"key": "responsible-for", "type": "clause", "offset": [1372, 1387]}, {"key": "use-of-the-project", "type": "clause", "offset": [1444, 1462]}, {"key": "other-tenants", "type": "clause", "offset": [1466, 1479]}, {"key": "maintenance-of", "type": "clause", "offset": [1546, 1560]}, {"key": "tenant-and-landlord", "type": "clause", "offset": [1612, 1631]}, {"key": "no-representation-or-warranty", "type": "clause", "offset": [1638, 1667]}, {"key": "with-respect-to", "type": "clause", "offset": [1668, 1683]}, {"key": "indemnify-and-hold-harmless", "type": "clause", "offset": [1730, 1757]}, {"key": "expenses-of", "type": "clause", "offset": [1831, 1842]}, {"key": "arising-out-of", "type": "definition", "offset": [1934, 1948]}, {"key": "removal-of", "type": "clause", "offset": [2005, 2015]}, {"key": "prior-to-the-termination-date", "type": "clause", "offset": [2037, 2066]}, {"key": "compensation-to-tenant", "type": "clause", "offset": [2152, 2174]}, {"key": "the-condition", "type": "clause", "offset": [2337, 2350]}, {"key": "installation-of-the", "type": "clause", "offset": [2378, 2397]}, {"key": "electrical-panels", "type": "clause", "offset": [2424, 2441]}, {"key": "for-the-building", "type": "clause", "offset": [2442, 2458]}, {"key": "parking-areas", "type": "clause", "offset": [2501, 2514]}, {"key": "in-accordance-with", "type": "clause", "offset": [2574, 2592]}, {"key": "further-notice", "type": "clause", "offset": [2613, 2627]}, {"key": "from-landlord", "type": "clause", "offset": [2628, 2641]}], "size": 10, "samples": [{"hash": "ifYPMmdRVkl", "uri": "/contracts/ifYPMmdRVkl#backup-generator", "label": "Office Lease (XOMA Corp)", "score": 25.1916503906, "published": true}, {"hash": "fY0s8By8BOh", "uri": "/contracts/fY0s8By8BOh#backup-generator", "label": "Lease Agreement (XOMA Corp)", "score": 25.1916503906, "published": true}, {"hash": "13aY5zudyx9", "uri": "/contracts/13aY5zudyx9#backup-generator", "label": "Lease Agreement (XOMA Corp)", "score": 23.1916503906, "published": true}], "snippet": "Tenant to maintain in good operating condition and repair (including any required replacements), at Tenant\u2019s sole cost and expense, the backup generator currently located at the Project as well as the associated equipment and infrastructure (collectively, the \u201cGenerator\u201d). All such maintenance and Tenant\u2019s use of the Generator shall be subject to all applicable Laws, and any terms and conditions as may be reasonably imposed by Landlord; provided, however, that Landlord shall not charge Tenant any separate charge in connection with the same. Without limiting the generality of the foregoing, Tenant shall, at Tenant\u2019s sole cost and expense, obtain and maintain all necessary federal, state, and municipal permits, licenses and approvals, including without limitation any such permits, licenses and approvals from the Bay Area Air Quality Management District, and Tenant shall deliver copies thereof to Landlord. The Generator may be used by Tenant only during (a) testing and regular maintenance, and (b) any period of electrical power outage in the Project. Tenant shall be entitled to operate the Generator for testing and regular maintenance only upon notice to Landlord and at times reasonably approved by Landlord. Tenant shall ensure that the backup generator does not result in any Hazardous Materials being introduced to the Project. Further, Tenant shall be responsible for ensuring that the Generator does not interfere with the use of the Project by other tenants or tenants or occupants of surrounding buildings. Any repairs and maintenance of such Generator shall be the sole responsibility of Tenant and Landlord makes no representation or warranty with respect to such Generator. Tenant shall protect, defend, indemnify and hold harmless the Indemnitees from and against claims, damages, liabilities, costs and expenses of every kind and nature, including attorneys\u2019 fees, incurred by or asserted against Landlord arising out of Tenant\u2019s installation, maintenance, replacement, use or removal of the Generator. On or prior to the Termination Date, Tenant shall either (i) surrender the Generator in good operating condition without compensation to Tenant, or (ii) remove the Generator (including all the associated equipment and infrastructure) from the Project and repair and restore the Project and the Building to the condition which existed prior to the installation of the Generator (including, new electrical panels for the Building and restoring and restriping the affected parking areas), all at the sole cost and expense of Tenant and otherwise in accordance with this Lease, without further notice from Landlord.", "hash": "7a585e48207955c499a6287ff5343226", "id": 2}, {"snippet_links": [{"key": "the-parties-acknowledge", "type": "clause", "offset": [0, 23]}, {"key": "jointly-own", "type": "definition", "offset": [51, 62]}, {"key": "electrical-systems", "type": "definition", "offset": [120, 138]}, {"key": "fuel-storage-tank", "type": "definition", "offset": [150, 167]}], "size": 1, "samples": [{"hash": "bTTj7kEw9m4", "uri": "/contracts/bTTj7kEw9m4#backup-generator", "label": "Joint Occupancy and Use Agreement", "score": 32.8692245483, "published": true}], "snippet": "The Parties acknowledge that Aylmer and St. \u2587\u2587\u2587\u2587\u2587\u2587 jointly own a backup generator within the EMPS, including associated electrical systems, controls, fuel storage tank, and appurtenances, which benefit Aylmer and St. \u2587\u2587\u2587\u2587\u2587\u2587.", "hash": "d6439d36e86b18920fcc3b5c1843397f", "id": 9}, {"snippet_links": [{"key": "term-of-this-lease", "type": "clause", "offset": [15, 33]}, {"key": "tenant-shall", "type": "clause", "offset": [56, 68]}, {"key": "for-the-premises", "type": "clause", "offset": [122, 138]}, {"key": "no-representation-or-warranty", "type": "clause", "offset": [258, 287]}, {"key": "with-respect-to", "type": "clause", "offset": [288, 303]}, {"key": "condition-of", "type": "clause", "offset": [308, 320]}, {"key": "landlord-shall", "type": "clause", "offset": [383, 397]}, {"key": "repair-obligations", "type": "definition", "offset": [421, 439]}, {"key": "by-tenant", "type": "clause", "offset": [512, 521]}, {"key": "regular-maintenance", "type": "definition", "offset": [550, 569]}, {"key": "period-of", "type": "clause", "offset": [584, 593]}, {"key": "power-outage", "type": "definition", "offset": [605, 617]}, {"key": "to-operate", "type": "definition", "offset": [659, 669]}, {"key": "notice-to-landlord", "type": "clause", "offset": [737, 755]}, {"key": "by-landlord", "type": "clause", "offset": [789, 800]}, {"key": "in-addition", "type": "clause", "offset": [802, 813]}, {"key": "hazardous-materials", "type": "definition", "offset": [884, 903]}, {"key": "violation-of-applicable-law", "type": "clause", "offset": [939, 966]}, {"key": "to-tenant", "type": "definition", "offset": [997, 1006]}, {"key": "responsible-for", "type": "clause", "offset": [1063, 1078]}, {"key": "use-of-the-project", "type": "clause", "offset": [1142, 1160]}, {"key": "other-tenants", "type": "clause", "offset": [1164, 1177]}, {"key": "article-14", "type": "definition", "offset": [1262, 1272]}], "size": 1, "samples": [{"hash": "ibVK3KxvjrJ", "uri": "/contracts/ibVK3KxvjrJ#backup-generator", "label": "Standard Multi Tenant Lease (SCOLR Pharma, Inc.)", "score": 19.0, "published": true}], "snippet": "Throughout the Term of this Lease (as may be extended), Tenant shall be entitled to utilize the existing backup generator for the Premises. Tenant acknowledges that Landlord is providing such backup generator in its \"as is\" condition and that Landlord makes no representation or warranty with respect to the condition of such backup generator or its suitability for Tenant's use and Landlord shall have no maintenance or repair obligations with respect to the backup generator. Such backup generator may be used by Tenant only during (i) testing and regular maintenance, and (ii) any period of electrical power outage in the Project. Tenant shall be entitled to operate the backup generator for testing and regular maintenance only upon notice to Landlord and at times reasonably approved by Landlord. In addition, Tenant shall ensure that the backup generator does not result in any Hazardous Materials being introduced to the Project in violation of applicable law, and Section 28(a) will apply to Tenant's use of the backup generator. Further, Tenant shall be responsible for ensuring that the backup generator does not interfere with the use of the Project by other tenants. Such backup generator shall be deemed to be a part of the Premises for purposes of Article 14 of this Lease.", "hash": "36ed33b141543fc98a4c428cde5ff37b", "id": 10}, {"snippet_links": [{"key": "days-after", "type": "definition", "offset": [22, 32]}, {"key": "in-writing", "type": "definition", "offset": [50, 60]}, {"key": "the-building", "type": "definition", "offset": [64, 76]}, {"key": "the-supplier", "type": "clause", "offset": [139, 151]}, {"key": "at-tenant", "type": "definition", "offset": [188, 197]}, {"key": "cost-and-expense", "type": "clause", "offset": [205, 221]}, {"key": "the-area", "type": "clause", "offset": [240, 248]}, {"key": "schedule-a", "type": "definition", "offset": [258, 268]}, {"key": "in-accordance-with", "type": "clause", "offset": [384, 402]}, {"key": "the-second-amendment", "type": "clause", "offset": [421, 441]}, {"key": "schedule-b", "type": "clause", "offset": [445, 455]}, {"key": "from-tenant", "type": "clause", "offset": [568, 579]}, {"key": "equal-to", "type": "definition", "offset": [590, 598]}, {"key": "required-by", "type": "definition", "offset": [611, 622]}, {"key": "tenant-shall", "type": "clause", "offset": [662, 674]}, {"key": "payable-to", "type": "definition", "offset": [714, 724]}, {"key": "placement-of", "type": "definition", "offset": [794, 806]}, {"key": "installation-work", "type": "clause", "offset": [869, 886]}, {"key": "site-preparation", "type": "definition", "offset": [893, 909]}, {"key": "the-installation", "type": "clause", "offset": [928, 944]}, {"key": "delivery-of-the", "type": "clause", "offset": [973, 988]}, {"key": "landlord-shall", "type": "clause", "offset": [1024, 1038]}, {"key": "governmental-approvals-and-permits", "type": "definition", "offset": [1096, 1130]}, {"key": "relating-to", "type": "definition", "offset": [1131, 1142]}, {"key": "initial-installation", "type": "definition", "offset": [1147, 1167]}, {"key": "initial-operation", "type": "clause", "offset": [1172, 1189]}, {"key": "true-and-complete", "type": "clause", "offset": [1316, 1333]}, {"key": "original-counterparts", "type": "clause", "offset": [1334, 1355]}, {"key": "permits-and-approvals", "type": "definition", "offset": [1371, 1392]}, {"key": "operation-of-the", "type": "clause", "offset": [1426, 1442]}, {"key": "within-thirty", "type": "clause", "offset": [1469, 1482]}, {"key": "after-tenant", "type": "definition", "offset": [1493, 1505]}, {"key": "information-regarding", "type": "clause", "offset": [1644, 1665]}, {"key": "tenant-agrees-to", "type": "clause", "offset": [1758, 1774]}, {"key": "sole-expense", "type": "definition", "offset": [1826, 1838]}, {"key": "rules-and-regulations", "type": "clause", "offset": [1844, 1865]}, {"key": "in-connection-with", "type": "clause", "offset": [1906, 1924]}, {"key": "removal-of", "type": "clause", "offset": [2019, 2029]}, {"key": "if-required", "type": "definition", "offset": [2147, 2158]}, {"key": "by-landlord", "type": "clause", "offset": [2170, 2181]}, {"key": "pursuant-to", "type": "clause", "offset": [2290, 2301]}, {"key": "tenant-covenants", "type": "clause", "offset": [2464, 2480]}, {"key": "the-rights", "type": "clause", "offset": [2532, 2542]}, {"key": "any-person", "type": "clause", "offset": [2565, 2575]}, {"key": "the-development", "type": "clause", "offset": [2734, 2749]}, {"key": "the-operation", "type": "clause", "offset": [2869, 2882]}, {"key": "in-no-event", "type": "clause", "offset": [2924, 2935]}, {"key": "be-responsible", "type": "clause", "offset": [2936, 2950]}, {"key": "for-any-reason", "type": "clause", "offset": [2955, 2969]}, {"key": "direct-result", "type": "definition", "offset": [2994, 3007]}, {"key": "of-landlord", "type": "clause", "offset": [3008, 3019]}, {"key": "of-tenant", "type": "clause", "offset": [3050, 3059]}, {"key": "number-of-parking-spaces", "type": "definition", "offset": [3270, 3294]}, {"key": "the-placement", "type": "clause", "offset": [3315, 3328]}, {"key": "all-amounts-due", "type": "clause", "offset": [3402, 3417]}, {"key": "trade-fixtures", "type": "clause", "offset": [3502, 3516]}, {"key": "paragraph-8", "type": "clause", "offset": [3554, 3565]}, {"key": "termination-of-the-lease", "type": "clause", "offset": [3671, 3695]}, {"key": "damage-or-injury", "type": "clause", "offset": [3774, 3790]}, {"key": "caused-by", "type": "clause", "offset": [3791, 3800]}, {"key": "failure-to", "type": "clause", "offset": [3840, 3850]}, {"key": "comply-with-the", "type": "clause", "offset": [3860, 3875]}, {"key": "holding-over", "type": "clause", "offset": [3936, 3948]}, {"key": "the-premises", "type": "clause", "offset": [3952, 3964]}, {"key": "efforts-to-complete", "type": "clause", "offset": [4141, 4160]}, {"key": "restoration-work", "type": "clause", "offset": [4177, 4193]}, {"key": "if-tenant", "type": "clause", "offset": [4298, 4307]}, {"key": "compensation-to-tenant", "type": "clause", "offset": [4552, 4574]}, {"key": "sole-risk", "type": "clause", "offset": [4640, 4649]}, {"key": "upon-landlord", "type": "definition", "offset": [4858, 4871]}, {"key": "indemnify-and-hold", "type": "clause", "offset": [4896, 4914]}, {"key": "liabilities-and-expenses", "type": "clause", "offset": [4945, 4969]}, {"key": "with-regard-to", "type": "clause", "offset": [4985, 4999]}, {"key": "general-liability-and-property-damage-insurance", "type": "clause", "offset": [5229, 5276]}, {"key": "in-compliance-with", "type": "definition", "offset": [5277, 5295]}, {"key": "the-requirements", "type": "clause", "offset": [5304, 5320]}, {"key": "references-in", "type": "clause", "offset": [5373, 5386]}, {"key": "this-article", "type": "definition", "offset": [5387, 5399]}, {"key": "related-equipment", "type": "clause", "offset": [5509, 5526]}, {"key": "by-tenant-to-landlord", "type": "clause", "offset": [5601, 5622]}, {"key": "additional-rent", "type": "definition", "offset": [5662, 5677]}, {"key": "written-demand", "type": "clause", "offset": [5781, 5795]}], "size": 3, "samples": [{"hash": "3Tr0wqW5Fxv", "uri": "/contracts/3Tr0wqW5Fxv#backup-generator", "label": "Lease Agreement (Rocket Companies, Inc.)", "score": 29.5133476257, "published": true}, {"hash": "deGyAQc1Bvt", "uri": "/contracts/deGyAQc1Bvt#backup-generator", "label": "Lease Agreement (Rocket Companies, Inc.)", "score": 29.4750175476, "published": true}], "snippet": "(a) Within sixty (60) days after Landlord accepts in writing at the Building delivery of both Backup Generators (hereinafter defined) from the supplier of the Backup Generators, Landlord, at Tenant\u2019s sole cost and expense, shall install in the area shown on Schedule A attached hereto and made a part hereof two (2) 1500KW auto transfer diesel backup generators (\u201cBackup Generators\u201d) in accordance with plans attached to the Second Amendment as Schedule B and made a part thereof. Landlord will order the Backup Generators within five (5) days after Landlord receives from Tenant an amount equal to the deposit required by the supplier of the Backup Generators. Tenant shall give Landlord a check for that deposit payable to Landlord within five (5) days after Landlord\u2019s demand therefor. Upon placement of the order, Landlord, at Tenant\u2019s expense, shall commence pre- installation work (i.e. site preparation, wiring, etc.) so the installation is completed promptly after delivery of the Backup Generators to the Building. Landlord shall obtain, at Tenant\u2019s sole cost and expense, all necessary governmental approvals and permits relating to the initial installation and initial operation of both Backup Generators. Tenant, at its expense, shall thereafter keep current said approvals and permits and give Landlord true and complete original counterparts of all updated permits and approvals relating to the installation and operation of the two (2) Backup Generators within thirty (30) days after Tenant receives any such updated permit or approval.\n(b) Within thirty (30) days after Landlord\u2019s demand, Tenant shall furnish Landlord with any information regarding either or both Backup Generators and/or its (their) installation that Landlord may request. Tenant agrees to promptly comply with and strictly abide by, at its sole expense, any rules and regulations that Landlord may reasonably promulgate in connection with the installation, operation, repair, maintenance, replacement, relocation, concealment and/or removal of either or both Backup Generators. Tenant agrees to perform all repairs, maintenance, replacements, relocations (only if required in writing by Landlord), concealment and the removal (only if required in writing by Landlord) of either or both Backup Generators pursuant to Landlord\u2019s rules and regulations and in a manner that is compatible with the appearance and character of the corporate center of which the Building forms a part. Tenant covenants that neither Backup Generator shall interfere with the rights, health or welfare of any person or tenant. Tenant agrees that Landlord may install and operate, and may permit the installation and operation by others of, additional generators anywhere in the Development so long as the installation and operation of such additional generators do not materially and adversely interfere with the operation of the Backup Generators. Landlord shall in no event be responsible if, for any reason whatsoever (except as a direct result of Landlord\u2019s negligence), either or both of Tenant\u2019s Backup Generators do not perform to the expectations of Tenant. Landlord may reduce, at its sole option, the seven (7) parking space ratio referenced in Sections l.(p) and 36. (b) of the Lease to reflect the number of parking spaces lost as a result of the placement of both Backup Generators.\n(c) Once Tenant has paid Landlord in full for all amounts due Landlord under Section 51. (a) hereof, then, the Backup Generators shall constitute trade fixtures and shall fall within the purview of Paragraph 8. (d) (iii) of the Lease. Tenant shall, by no later than thirty (30) days after the expiration or earlier termination of the Lease and at Tenant\u2019s expense, remove both of the Backup Generators and restore any damage or injury caused by the removal of said Backup Generators. Failure to strictly comply with the immediately preceding sentence by Tenant shall constitute a holding over of the Premises by Tenant until such time as both of the Backup Generators are removed and any damage or injury caused by such removal is restored. Tenant, at its expense, shall exercise best efforts to complete its removal and restoration work sooner than the date falling thirty (30) days after the expiration or earlier termination of the Lease. If Tenant fails to strictly comply with the second (2nd) sentence of this Section 51.(c), then, Landlord, at its sole option, may, at Tenant\u2019s expense, (1) remove either or both of the Backup Generators, (2) keep either or both Backup Generators without compensation to Tenant, (3) discard either or both of the Backup Generators at Tenant\u2019s sole risk and with Tenant assuming all liability and/or (4) restore any damage or injury that either or both of said Backup Generators or the removal thereof may have caused. Tenant hereby releases Landlord from, and, upon Landlord\u2019s demand, shall defend, indemnify and hold Landlord harmless against any liabilities and expenses that may arise with regard to either or both of said Backup Generators, except for such liabilities and expenses that arise as a direct result of Landlord\u2019s negligence. Furthermore, in connection with both Backup Generators, Tenant shall procure and maintain general liability and property damage insurance in compliance with each of the requirements set forth in Sections 20. (a)-(b) of the Lease. All references in this Article 51 to \u201cBackup Generator\u201d shall include all wiring, cabling, fuse boxes, transformers and other ancillary and related equipment connecting the Backup Generator to the Premises. Any cost or expense owed by Tenant to Landlord under this Article 51 shall constitute additional rent under the Lease and shall be due from Tenant to Landlord within thirty (30) days after Tenant receives written demand therefor.", "hash": "2fc8940c771c5de248ac461b32f6b58e", "id": 4}, {"snippet_links": [{"key": "backup-power", "type": "definition", "offset": [13, 25]}, {"key": "permanently-installed", "type": "definition", "offset": [48, 69]}, {"key": "capable-of", "type": "definition", "offset": [80, 90]}, {"key": "the-generator", "type": "clause", "offset": [129, 142]}, {"key": "fuel-tank", "type": "clause", "offset": [205, 214]}, {"key": "duration-of", "type": "definition", "offset": [232, 243]}, {"key": "concrete-base", "type": "clause", "offset": [304, 317]}, {"key": "to-assist", "type": "clause", "offset": [525, 534]}, {"key": "asme-code", "type": "definition", "offset": [717, 726]}, {"key": "division-1", "type": "definition", "offset": [742, 752]}, {"key": "reinforced-concrete", "type": "definition", "offset": [896, 915]}, {"key": "other-structure", "type": "definition", "offset": [959, 974]}, {"key": "regulatory-specifications", "type": "definition", "offset": [979, 1004]}, {"key": "pea-gravel", "type": "definition", "offset": [1111, 1121]}], "size": 4, "samples": [{"hash": "ijIrOz7jEFV", "uri": "/contracts/ijIrOz7jEFV#backup-generator", "label": "Settlement Agreement", "score": 31.7342338562, "published": true}, {"hash": "5a2wVLdcwuX", "uri": "/contracts/5a2wVLdcwuX#backup-generator", "label": "Settlement Agreement", "score": 31.4303855896, "published": true}, {"hash": "jXgbufAfZK3", "uri": "/contracts/jXgbufAfZK3#backup-generator", "label": "Settlement Agreement", "score": 31.3756389618, "published": true}], "snippet": "1. Emergency backup power will be supplied by a permanently installed generator capable of providing adequate power to the well. The generator will be capable of producing 400KV. The generator will have a fuel tank capable of a run duration of 24hrs. Generator will be installed upon a steel re\u2212enforced concrete base and anchored securely. Installation will include 3\u201d Steel fuel lines run under ground between a 2000\u2212gallon fuel tank and the generator. Concrete filled steel bollards will be installed around the fuel tank to assist in preventing vehicle or equipment impact.\n2. A single 2000\u2212gallon tank will be furnished and installed to accommodate the 400KV generator. The tank will be fabricated to the latest ASME code, Section VIII, Division 1. The tank will be equipped with liquid withdrawal and vapor withdrawal port. This tank is also equipped with safety relief valving.\n3. A steel reinforced concrete pad will be installed approx. 50\u2019 from any other structure per regulatory specifications to accommodate the tank. The pad will be approximately 25\u2019 x 6\u2019x 6\u201d and be formed and poured with 4500PSI pea gravel pump mix concrete.", "hash": "aa1d0945a287776a0ad16300155a9ad6", "id": 3}, {"snippet_links": [{"key": "date-hereof", "type": "clause", "offset": [10, 21]}, {"key": "the-lease", "type": "clause", "offset": [109, 118]}], "size": 2, "samples": [{"hash": "3Tr0wqW5Fxv", "uri": "/contracts/3Tr0wqW5Fxv#backup-generator", "label": "Lease Agreement (Rocket Companies, Inc.)", "score": 29.5133476257, "published": true}, {"hash": "deGyAQc1Bvt", "uri": "/contracts/deGyAQc1Bvt#backup-generator", "label": "Lease Agreement (Rocket Companies, Inc.)", "score": 29.4750175476, "published": true}], "snippet": "As of the date hereof, the following Article 51 BACKUP GENERATOR shall be deemed added to and made a part of the Lease:", "hash": "536b30315b9907b484a4c190c4a7bf32", "id": 5}, {"snippet_links": [{"key": "the-parties-hereto", "type": "clause", "offset": [0, 18]}, {"key": "the-premises", "type": "clause", "offset": [101, 113]}, {"key": "the-terms-and-conditions", "type": "clause", "offset": [144, 168]}, {"key": "the-generator", "type": "clause", "offset": [260, 273]}, {"key": "cost-and-expense", "type": "clause", "offset": [306, 322]}, {"key": "separate-meter", "type": "definition", "offset": [340, 354]}, {"key": "be-responsible", "type": "clause", "offset": [424, 438]}, {"key": "all-necessary-approvals", "type": "clause", "offset": [492, 515]}, {"key": "master-landlord", "type": "definition", "offset": [525, 540]}, {"key": "in-connection-with", "type": "clause", "offset": [541, 559]}, {"key": "installation-of", "type": "clause", "offset": [564, 579]}], "size": 2, "samples": [{"hash": "lgT4hZdubxG", "uri": "/contracts/lgT4hZdubxG#backup-generator", "label": "Sublease (Natera, Inc.)", "score": 26.4127311707, "published": true}, {"hash": "5vAgubnUIKB", "uri": "/contracts/5vAgubnUIKB#backup-generator", "label": "Sublease (Natera, Inc.)", "score": 25.3641338348, "published": true}], "snippet": "The parties hereto acknowledge that Sublandlord has installed a 350Kw backup generator that services the Premises (the \u201cGenerator\u201d). Subject to the terms and conditions set forth herein, Subtenant shall be entitled to use up to 30Kw of electricity produced by the Generator. Subtenant, at Subtenant\u2019s sole cost and expense, shall install a separate meter to measure the electricity and any necessary wiring. Subtenant shall be responsible, at Subtenant\u2019s sole cost and expense, for obtaining all necessary approvals from the Master Landlord in connection with the installation of such separate meter and wiring.", "hash": "f053f7be04e60f7468a6900235ec72dc", "id": 6}, {"snippet_links": [{"key": "rent-commencement-date", "type": "clause", "offset": [19, 41]}, {"key": "additional-space", "type": "definition", "offset": [49, 65]}, {"key": "tenant-shall", "type": "clause", "offset": [67, 79]}, {"key": "responsible-for", "type": "clause", "offset": [93, 108]}, {"key": "gas-and-electric", "type": "clause", "offset": [151, 167]}, {"key": "agreement-for", "type": "clause", "offset": [186, 199]}, {"key": "purchase-of", "type": "clause", "offset": [200, 211]}, {"key": "generation-service", "type": "definition", "offset": [219, 237]}], "size": 1, "samples": [{"hash": "lHGqJSk9hmP", "uri": "/contracts/lHGqJSk9hmP#backup-generator", "label": "Lease Agreement (Pharmaceutical Product Development Inc)", "score": 19.0, "published": true}], "snippet": "Beginning with the Rent Commencement Date on the Additional Space, Tenant shall become fully responsible for any and all obligations under the Madison Gas and Electric, Electric Service Agreement for Purchase of Backup Generation Service.", "hash": "da148ad60e0ef56ac141128019b7e2c6", "id": 7}, {"snippet_links": [{"key": "tenant-shall", "type": "clause", "offset": [0, 12]}, {"key": "right-to-use", "type": "definition", "offset": [22, 34]}, {"key": "existing-generator", "type": "clause", "offset": [39, 57]}, {"key": "on-the-premises", "type": "definition", "offset": [58, 73]}, {"key": "operate-and-maintain", "type": "definition", "offset": [103, 123]}, {"key": "cost-and-expense", "type": "clause", "offset": [150, 166]}, {"key": "the-generator", "type": "clause", "offset": [185, 198]}, {"key": "to-landlord", "type": "definition", "offset": [199, 210]}, {"key": "termination-of-the-lease-term", "type": "clause", "offset": [240, 269]}, {"key": "same-condition", "type": "clause", "offset": [277, 291]}, {"key": "as-received", "type": "definition", "offset": [292, 303]}, {"key": "from-landlord", "type": "clause", "offset": [304, 317]}, {"key": "ordinary-wear", "type": "definition", "offset": [347, 360]}, {"key": "reasonable-maintenance-and-repair", "type": "clause", "offset": [413, 446]}, {"key": "if-tenant", "type": "clause", "offset": [467, 476]}, {"key": "replace-the", "type": "clause", "offset": [487, 498]}, {"key": "same-location", "type": "definition", "offset": [530, 543]}, {"key": "landlord-and-tenant", "type": "clause", "offset": [571, 590]}, {"key": "mutually-agree", "type": "definition", "offset": [591, 605]}, {"key": "agreement-to-be", "type": "clause", "offset": [610, 625]}, {"key": "each-party", "type": "clause", "offset": [629, 639]}, {"key": "sole-discretion", "type": "definition", "offset": [642, 657]}, {"key": "at-tenant", "type": "definition", "offset": [704, 713]}, {"key": "to-operate", "type": "definition", "offset": [807, 817]}, {"key": "property-of-landlord", "type": "clause", "offset": [940, 960]}], "size": 1, "samples": [{"hash": "gwFN9abxn2C", "uri": "/contracts/gwFN9abxn2C#backup-generator", "label": "Lease Agreement (Genesis Microchip Inc /De)", "score": 21.0, "published": true}], "snippet": "Tenant shall have the right to use the existing generator on the Premises, provided, that Tenant shall operate and maintain said generator at its own cost and expense, and shall return the generator to Landlord at the expiration or earlier termination of the Lease Term in the same condition as received from Landlord when Tenant takes occupancy, ordinary wear which could not have been prevented by commercially reasonable maintenance and repair practices excepted. If Tenant elects to replace the generator, it may do so at the same location or any other location that Landlord and Tenant mutually agree on, agreement to be in each party\u2019s sole discretion. If a new generator is installed, it shall be at Tenant\u2019s sole cost and expense, Tenant shall have the duty to use commercially reasonable practices to operate and maintain the generator, and on the expiration or earlier termination of the Lease, the new generator shall become the property of Landlord.", "hash": "a61ef61dfab204c6a5bdc149332fd3ab", "id": 8}], "next_curs": "ClkSU2oVc35sYXdpbnNpZGVyY29udHJhY3RzcjULEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IhliYWNrdXAtZ2VuZXJhdG9yIzAwMDAwMDBhDKIBAmVuGAAgAA==", "clause": {"parents": [["miscellaneous-provisions", "Miscellaneous Provisions"], ["repairs-and-alterations", "Repairs and Alterations"], ["project-services", "Project Services"], ["miscellaneous", "Miscellaneous"], ["general-provisions", "General Provisions"]], "children": [["intentionally-deleted", "Intentionally Deleted"], ["", ""], ["no-liability", "No Liability"], ["use-charges", "Use Charges"], ["extended-outage-protocols", "Extended Outage Protocols"]], "size": 42, "title": "Backup Generator", "id": "backup-generator", "related": [["generator", "Generator", "Generator"], ["emergency-generator", "Emergency Generator", "Emergency Generator"], ["generators", "Generators", "Generators"], ["synchronous-generation", "Synchronous Generation", "Synchronous Generation"], ["non-synchronous-generation", "Non-Synchronous Generation", "Non-Synchronous Generation"]], "related_snippets": [], "updated": "2026-02-28T04:48:56+00:00", "also_ask": ["What minimum performance and maintenance standards should be mandated for the backup generator clause?", "How can liability for generator failure or insufficient capacity be allocated or limited?", "What are the most common negotiation points regarding fuel supply, testing, and access rights?", "How do backup generator obligations in this clause compare to industry or local code requirements?", "What evidence is needed to prove breach or enforceability of the backup generator clause in court?"], "drafting_tip": "Specify maintenance obligations and testing frequency to ensure reliability; define responsibility for fuel supply to prevent operational gaps; clarify activation procedures to avoid confusion during outages.", "explanation": "The Backup Generator clause outlines the requirements and responsibilities related to providing and maintaining a backup power source at a facility or project site. Typically, this clause specifies who is responsible for supplying, installing, and servicing the generator, as well as the standards it must meet and the circumstances under which it must operate, such as during power outages or emergencies. Its core function is to ensure continuity of operations and safety by guaranteeing that essential systems remain powered when the main electrical supply is interrupted."}, "json": true, "cursor": ""}}