BUILDING PERMIT PHASE Sample Clauses

BUILDING PERMIT PHASE. 6.1 DESIGN PROFESSIONAL is responsible for cooperating with and providing assistance to OWNER and CONSTRUCTION MANAGER @ RISK with respect to the applicable building permit application process and the issuance of all necessary and required permits for the Project. 6.2 As part of the building permit application package, the DESIGN PROFESSIONAL shall provide the applicable building permit office with the number of complete sets of signed and sealed Construction Documents and all other bidding documents prepared by the DESIGN PROFESSIONAL as indicated in the Deliverable Schedule set forth in the Guidelines. Each of the drawings and the cover sheet of the Project Manual shall be signed, sealed, and dated by the DESIGN PROFESSIONAL per Georgia Statutes. 6.3 As part of the building permit application process, the Building Code Official (“BCO”) shall review and provide comments to the DESIGN PROFESSIONAL on the submitted Construction Documents. DESIGN PROFESSIONAL shall revise the Construction Documents by incorporating necessary revisions to address mandatory inclusions made by Standards and Design, the Program Manager and the office of the BCO. The revised final Construction Documents shall be signed and sealed by the DESIGN PROFESSIONAL and re-submitted to the Program Manager in the quantities indicated in the Deliverable Schedule. Once this revised set of Construction Documents is approved by OWNER, it will be deemed to be the final approved set of Construction Documents upon which the construction of the Project is to be based.
AutoNDA by SimpleDocs
BUILDING PERMIT PHASE. 6.1 DESIGN PROFESSIONAL is responsible for cooperating with and providing assistance to OWNER and CONTRACTOR with respect to the applicable building permit application process and the issuance of all necessary and required permits for the Project. 6.2 As part of the building permit application package, the DESIGN PROFESSIONAL shall provide the OWNER’S Project Manager with four (4) complete sets of signed and sealed Construction Documents and all other bidding documents prepared by the DESIGN PROFESSIONAL. Each of the drawings and the cover sheet of the Project Manual shall be signed, sealed, and dated by the DESIGN PROFESSIONAL per Florida Statutes. The submittal shall incorporate resolutions to all previous comments made by the OWNER and Authorities Having Jurisdiction. 6.3 As part of the building permit application process, the OWNER and the OWNER’S Building Code Compliance Official (“BCCO”) and Authorities Having Jurisdiction shall review and provide comments to the DESIGN PROFESSIONAL on the submitted Construction Documents. DESIGN PROFESSIONAL shall revise the Construction Documents by incorporating necessary revisions to address mandatory inclusions made by OWNER, the Project Manager, the office of the BCCO and Authorities Having Jurisdiction. The revised final Construction Documents shall be signed and sealed by the DESIGN PROFESSIONAL and re- submitted to the Project Manager along with responses and remedies from the DESIGN PROFESSIONAL to any comments made on the Plan Review Commentary Sheet by any of the noted parties. The DESIGN PROFESSIONAL shall provide four (4) complete sets of these documents. Once this revised set of Construction Documents is approved by OWNER, it will be deemed to be the final approved set of Construction Documents upon which the construction of the Project is to be based.
BUILDING PERMIT PHASE. 6.1 DESIGN PROFESSIONAL is responsible for cooperating with and providing assistance to OWNER and CONSTRUCTION CONTRACTOR with respect to the applicable building permit application process and the issuance of all necessary and required permits for the Project. 6.2 As part of the building permit application package, the DESIGN PROFESSIONAL shall provide the applicable building permit office with the number of complete sets of signed and sealed Construction Documents and all other bidding documents prepared by the DESIGN PROFESSIONAL as indicated in the Deliverable Schedule set forth in the Guidelines. Each of the drawings and the cover sheet of the Project Manual shall be signed, sealed, and dated by the DESIGN PROFESSIONAL per Florida Statutes. 6.3 As part of the building permit application process, the Building Code Compliance Official (“BCCO”) shall review and provide comments to the DESIGN A-8 (SDP-CM) PROFESSIONAL on the submitted Construction Documents. DESIGN PROFESSIONAL shall revise the Construction Documents by incorporating necessary revisions to address mandatory inclusions made by Facilities Services Design, the Project Manager and the office of the BCCO. The revised final Construction Documents shall be signed and sealed by the DESIGN PROFESSIONAL and re-submitted to the Project Manager in the quantities indicated in the Deliverable Schedule. Once this revised set of Construction Documents is approved by OWNER, it will be deemed to be the final approved set of Construction Documents upon which the construction of the Project is to be based.
BUILDING PERMIT PHASE. 6.1 DESIGN PROFESSIONAL is responsible for cooperating with and providing assistance to OWNER and CONSTRUCTION CONTRACTOR with respect to the applicable building permit application process and the issuance of all necessary and required permits for the Project. 6.2 As part of the building permit application package, the DESIGN PROFESSIONAL shall provide the applicable building permit office with the number of complete sets of signed and sealed Construction Documents and all other bidding documents prepared by the DESIGN PROFESSIONAL as indicated in the OWNER’S published standards. Each of the drawings and the cover sheet of the Project Manual shall be signed, sealed, and dated by the DESIGN PROFESSIONAL per Florida Statutes. 6.3 As part of the building permit application process, the Building Code Manager (“BCM") shall review and provide comments to the DESIGN PROFESSIONAL on the submitted Construction Documents. DESIGN PROFESSIONAL shall revise the Construction Documents through Addenda prior to establishment of a Guaranteed Maximum Price (GMP) by the Construction Manager or by Supplemental Instructions, Contingency Adjustment or Change Order post GMP, incorporating necessary revisions to address mandatory inclusions made by the Project Coordinator and the office of the Building Officials reviewing the Construction Documents. Revisions shall be signed and sealed by the DESIGN PROFESSIONAL and distributed in accordance with the OWNER’S published standards.
BUILDING PERMIT PHASE. 6.1. DESIGN PROFESSIONAL is responsible for cooperating with and providing assistance to OWNER and CONSTRUCTION CONTRACTOR with respect to the applicable building permit application process and the issuance of all necessary and required permits for the Project. 6.2. As part of the building permit application package, the DESIGN PROFESSIONAL shall provide the applicable building permit office with the number of complete sets of signed and sealed Construction Documents and all other bidding documents prepared by the DESIGN PROFESSIONAL as indicated in the OWNER’S Published Standards. Each of the drawings and the cover sheet of the Project Manual shall be signed, sealed, and dated by the DESIGN PROFESSIONAL per Florida Statutes. 6.3. As part of the building permit application process, the Building Code Manager (“BCM") shall review and provide comments to the DESIGN PROFESSIONAL on the submitted Construction Documents. DESIGN PROFESSIONAL shall revise the Construction

Related to BUILDING PERMIT PHASE

  • Building Permit The Owner shall pay for all permits. The Owner and AE shall be required to provide such information to the Permitting Authority as is necessary to obtain approval from the Permitting Authority to commence construction prior to beginning construction. The CM shall pull the Building Permit, and shall be responsible for delivering and posting the Building Permit at the Project Site prior to the commencement of construction. The Owner and AE shall fully cooperate with the CM when and where necessary.

  • Building Permits All building permits required for the construction of the Improvements have been obtained prior to the commencement of the construction of the Improvements and copies of same will be delivered to Lessor.

  • Premises Building Project and Common Areas 1.1 Premises, Building, Project and Common Areas.

  • PARKING PERMITS A. Must be obtained on the day of move in. B. Towing charges resulting from violations will be the responsibility of the RESIDENT. C. Any form of duplication of parking permits is a violation of the LEASE AGREEMENT, and may be grounds for eviction. Note: Refer to Resident Handbook for further detail.

  • Construction Phase Part 1 –

  • Tenant Improvements Landlord shall cause the Core and Shell Contractor or another Contractor designated by Landlord and approved by Tenant, such consent not to be unreasonably withheld or delayed (“TI Contractor”, and together with Core and Shell Contractor, “Contractor”) to commence and thereafter diligently prosecute the construction of the tenant improvements in the Premises pursuant to the Work Letter (the “Tenant Improvements”); provided, however, that before performing the Tenant Improvements, Landlord shall prepare in good faith an estimated budget for the construction of the Tenant Improvements and deliver such budget to Tenant for Tenant’s written approval prior the start of construction (the “Budget”). Landlord and Tenant shall work together cooperatively and in good faith to achieve a mutually acceptable Budget. Landlord shall update the Budget for Tenant’s review and approval at reasonable intervals and shall notify Tenant in writing if the Budget is likely to be exceeded. If there is an indication that the Budget is likely to be exceeded, Landlord and Tenant shall work together cooperatively, if required by Tenant, to modify the scope of the Tenant Improvements to bring the same in line with a budget reasonably acceptable to Tenant. The Tenant Improvements shall be performed in a workmanlike manner and shall substantially conform with Applicable Laws and the Approved TI Plans (as defined in the Work Letter). Tenant shall pay all TI Costs, except that Landlord shall pay for TI Costs that do not exceed the TI Allowance. The “TI Allowance” shall mean (a) One Hundred Twenty Five Dollars ($125.00) per rentable square foot of the Premises (the “Initial TI Allowance”), together with (b) the Additional Allowance. The “TI Costs” shall mean all Tenant Core and Shell Costs (as defined in the Work Letter) and all costs and expenses of performing the TI Work, including without limitation the hard and soft costs of (i) construction, (ii) the Construction Management Fee (as such term is defined in the Work Letter) and any Project or construction management fees paid by Tenant to an unaffiliated third party (such fees not to exceed three percent (3%) of the TI Allowance), (iii) space planning, design, architect, engineering, data and phone cabling and other related services, (iv) costs and expenses for labor, material, equipment, data and phone cabling and fixtures (including, without limitation, any of the Attached Property (as defined in Section 18.5), (v) building permits and other taxes, fees, charges and levies by governmental and quasi-governmental agencies for permits or for inspections of the Tenant Improvements, and (vi) the Warm Shell Costs. In no event shall the TI Allowance be used for: (w) the purchase of any furniture, personal property or other non-building system equipment, (x) costs resulting from a Tenant Delay, (y) costs resulting from any default by Tenant of its obligations under this Lease, or (z) costs that are recoverable or reasonably recoverable by Tenant from a third party (e.g., insurers, warrantors, or tortfeasors). In the event the estimated total TI Costs (as set forth in the Budget) exceed the TI Allowance, Tenant shall deposit with Landlord such overage (the “TI Allowance Excess”), within five (5) business days of receiving the Budget (the “TI Deposit”). In the event Landlord determines the estimate of the TI Costs set forth in the Budget underestimates the amount of TI Costs so that the TI Deposit will not be sufficient to cover the TI Allowance Excess, then Landlord shall communicate the same to Tenant and, if required by Tenant, the parties shall discuss revisions to the Budget and Tenant may make a TI Tenant Change Order Request to reduce TI Costs, and unless the TI Costs are reduced to be within the Budget and previously paid TI Deposit, Tenant shall promptly pay the additional amount to Landlord, and such additional amount shall be added to the TI Deposit. If the sum of the TI Allowance plus the TI Deposit is not sufficient to cover the TI Costs, Tenant shall reimburse Landlord the difference between (a) the TI Costs and (b) the sum of the TI Allowance and the TI Deposit. However, Landlord shall be solely responsible for any costs related to the Tenant Improvements to the extent the same result from Landlord’s gross negligence, intentional misconduct or breach of Lease. Landlord and Tenant shall work together cooperatively at no cost or risk to Landlord to maximize Tenant’s ability, to the extent reasonably possible, to obtain the benefit of any applicable research and development tax credits with respect to the Tenant Improvements.

  • LANDLORD'S ACCESS TO PREMISES Landlord reserves and shall at any time upon reasonable notice and in compliance with Tenant’s reasonable security measures have the right to enter the Premises to inspect the same, to supply any service to be provided by Landlord to Tenant hereunder to service and repair HVAC units, water pipes and sprinkler mains, and electrical and telephone risers servicing other parts of the Building, to show said Premises to prospective purchasers or tenants, to alter or repair the Premises or any portion of the Building, and to place “for sale” or “for rent” signs on the Building, all without being deemed guilty of an eviction of Tenant and without abatement of Rent, provided that the business of Tenant shall be interfered with as little as is reasonably practicable. Tenant hereby waives any claim for damages or any inconvenience to or interference with Tenant’s business, any loss of quiet enjoyment of the Premises and any other loss occasioned thereby. For each of the aforesaid purposes, Landlord shall at all times have and retain a key with which to unlock the main door to the Premises but not Tenant’s vaults and safes, and Landlord shall have the right to use any and all means which Landlord may deem proper to open said door in an emergency in order to obtain entry to the Premises, and any entry to the Premises obtained by Landlord by any of said means shall not under any circumstances be construed or deemed to be a forcible or unlawful entry into, or a detainer of the Premises, or any eviction of Tenant from the Premises or any portion thereof. No provision of this Lease shall be construed as obligating Landlord to perform any repairs, alterations or decoration except as otherwise expressly agreed to be performed by Landlord.

  • Construction of the Tenant Improvements (a) Tenant shall construct and install the Tenant Improvements in a good and workmanlike manner, in compliance with all Laws and in accordance with this Exhibit B. Tenant’s proposed architect/engineer, general contractor, and fire protection, plumbing, HVAC and electrical subcontractors are subject to Landlord’s prior approval. Promptly following the selection and approval of the architect/engineer, Tenant shall forward to said architect/engineer (and copy Landlord on the transmittal) Landlord’s building standards heretofore delivered to Tenant, and Tenant shall cause said architect/engineer to comply with said building standards. Promptly following the selection and approval of the general contractor, Tenant shall forward to said general contractor (and copy Landlord on the transmittal) Landlord’s fire protection, plumbing, HVAC and electrical specifications and Landlord’s rules of conduct, all of which have been delivered to Tenant prior to the date of this Lease, and Tenant shall cause said general contractor to comply with said specifications and rules of conduct. At Landlord’s request, Tenant shall coordinate a meeting among Landlord (who will reasonably make its representative available for such meeting), Tenant and Tenant’s general contractor to discuss the Building systems and other matters related to the construction of the Tenant Improvements. (b) Promptly following the date hereof, Tenant shall prepare and submit to Landlord a set of permittable construction drawings (the “CDs”), based on the preliminary plans attached hereto as Exhibit B-2 and made a part hereof (the “Preliminary Plans”), covering all work to be performed by Tenant in constructing the Tenant Improvements. Tenant shall have no right to make any Tenant Improvements that would materially alter the exterior appearance of the Building or the Building systems without Landlord’s prior approval. Landlord shall have fifteen (15) days after receipt of the CDs in which to review the CDs and in which to give Tenant written notice of its approval of the CDs or its requested changes to the CDs in reasonably sufficient detail so as to allow Tenant to make the requested changes (provided that Landlord shall not be permitted to request a change that is inconsistent with the Preliminary Plans). If Landlord requests any changes to the CDs, Tenant shall make such changes and shall, within fifteen (15) days of its receipt of Landlord’s requested changes (if any), submit the revised portion of the CDs to Landlord. Landlord shall have five (5) business days after receipt of the revised CDs in which to review said revised CDs and in which to give to Tenant written notice of its approval of the revised CDs or its requested changes thereto. This process shall continue until such time, if at all, that Landlord approves the CDs in accordance with this Section 2. Tenant shall at all times in its preparation of the CDs, and of any revisions thereto, act reasonably and in good faith. Landlord shall at all times in its review of the CDs, and any revisions thereto, act reasonably and in good faith.

  • Notice to Proceed - Site Improvements The Recipient shall not commence, or cause to be commenced, any site improvements or other work on the Land until the Director has issued a Notice to Proceed to the Recipient. Such Notice to Proceed will not be issued until the Director is assured that the Recipient has complied with all requirements for the approval of a grant under Revised Code Sections 164.20 through 164.27 and has completed any land acquisition required by the Project. A Notice to Proceed shall be required for all Project prime contractors or direct procurement initiated by the Recipient following execution of this Agreement.

  • Tenant Improvement Plans Any work proposed by Tenant (the “Tenant Improvements”) shall be subject to Landlord’s reasonable prior approval and shall be subject to the other terms and conditions of this Exhibit C; provided that it will be reasonable for Landlord to withhold its approval or consent (as and when applicable under this Exhibit C) if Landlord’s Mortgagee has not consented to the matter that is the subject of such approval or consent. All architectural, engineering and other design fees shall be paid by Tenant. Tenant shall use its architect, engineers and other design professionals, all of whom shall comply with any applicable licensing or governmental requirements of the City of Seattle and the State of Washington; Tenant’s architect shall be approved by Landlord (“Tenant’s Architect”), which approval shall not be unreasonably withheld, conditioned or delayed. Landlord shall also be entitled to receive a copy of the agreement between Tenant and Tenant’s Architect (the “Architect Agreement”). Tenant shall cause Tenant’s Architect to prepare a draft space plan (the “Space Plan”) for the Tenant Improvements and shall submit the proposed Space Plan to Landlord for the latter’s approval (not to be unreasonably withheld) in a time period to allow Tenant to timely complete its Tenant Improvements under this Lease. Landlord shall deliver to Tenant any written objections, questions or comments of Landlord with regard to the Space Plan within ten (10) business days of receipt; Landlord’s consent thereto shall be deemed given if not denied in writing within said ten (10) business day period. If Landlord denies its approval, it shall specify the reasons for doing so in detail. Tenant shall cause the Space Plan to be revised to address such written comments and shall resubmit said Space Plan to Landlord for approval. Such process shall continue until Landlord has approved the Space Plan. Tenant’s Architect shall then prepare working drawings and specifications for the Tenant Improvements, including architectural, structural, plumbing, mechanical, electrical, and fire protection drawings as required, suitable for permit application (the “Working Drawings”) and shall submit the proposed Working Drawings to Landlord for the latter’s approval in a time period to allow Tenant to timely complete its Tenant Improvements under this Lease. The Space Plan and Working Drawings shall be subject to Landlord’s approval, which Landlord agrees shall not be unreasonably withheld, conditioned, or delayed. Landlord shall not be deemed to have acted unreasonably if it withholds its approval thereof because, in Landlord’s reasonable opinion, the work, as described in any such item: (i) is likely to adversely affect Building Systems, the structure of the Building or the safety of the Building and/or their occupants; (ii) might impair Landlord’s ability to furnish services to Tenant or other tenants in the Building; (iii) would materially increase the cost of operating the Building; (iv) would violate any governmental laws, rules or ordinances (or interpretations thereof); (v) contains or uses hazardous or toxic materials or substances; (vi) would negatively affect the appearance of the Building; (vii) is reasonably likely to adversely affect another tenant’s premises; or (viii) is prohibited by any ground lease affecting the Building or any mortgage, trust deed or other instrument encumbering the Building. Landlord shall deliver to Tenant any written objections, questions or comments of Landlord with regard to the Working Drawings, within ten (10) business days of Landlord’s receipt of the Working Drawings; Landlord’s consent thereto shall be deemed given if not denied in writing within said ten (10) business day period. If Landlord denies its approval, it shall specify the reasons for doing so in detail. Tenant shall cause the Working Drawings to be revised to address such written comments and shall resubmit said Working Drawings to Landlord for approval. Landlord may, when approving the Tenant Improvement Plans, elect to require Tenant to remove any Non-Standard Improvements which are made to the Premises. If Landlord so elects, Tenant shall, at its own cost, restore the Premises to the condition designated by Landlord in its election, before the last day of the Term. Such process shall continue until both parties have approved the Working Drawings. Landlord’s approval of the Space Plan and/or the Working Drawings shall not be deemed any representation or warranty that the same comply with applicable codes.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!