Building Structure Sample Clauses

Building Structure. “Building Structure” means the foundations, floor/ceiling slabs, roofs, exterior walls, exterior glass and mullions, columns, beams, shafts (including elevator shafts), stairs, stairwells, elevators, Building mechanical, electrical and telephone closets, Common Areas, public areas, and any other structural components in the Building. The Building Structure excludes the Leasehold Improvements (and similar improvements to other premises) and the Mechanical Systems.
AutoNDA by SimpleDocs
Building Structure. Reinforced Cement Concrete (1:2:4) Framework, MAIN WALLS & PARTITION WALLS:- 200 MM/250 MM Thick Cement Brick Work for Main Walls and 125 MM Thick and 75 MM Thick Cement brickwork (1:4) for Flat Separating Wall and Partition Walls inside the respectively, FLOOR:- Vitrified Floor Titles (Glossy/Polished or Xxxx Xxxxxx as per the wish and demand of the Owners and also Flat Purchasers for All room, Verandah/Balcony, Hall, Kitchen and Anti-Skid Tiles in Bathroom/Toilet.
Building Structure. Reinforced Cement Concrete (R.C.C) Framed Structure 2. MAIN WALLS & PARTITION WALLS:- 200 MM/250 MM Thick/ Fly Ash Brick Work/Red Brick/AAC Block for Main Walls and 75 MM/ 100 MM / 125 MM Thick Cement brickwork for Flat Separating Wall and Partition Walls inside the respectively,
Building Structure. (a) All foundations to include footings, piers, caissons, pilings, grade beams, foundation walls or other building foundation components required to support the building structure. (b) Five inch (5") thick concrete slab on grade with below grade vapor barrier and welded wire mesh and any other reinforcing or structural connections that may be necessary or required as specified by structural engineer. (c) Complete structural framing system comprised of rolled steel or pipe columns, light weight braced-frame steel structure with corrugated metal deck and concrete toping over and open-web bar joist and girder floor support system, all members fireproofed as required by code. Floor support system shall provide for a minimum of 120 pounds per square foot live load. (d) Tinted high performance glass with Xxxxxxxxx composite metal panels including required caulking and sealants. Four
Building Structure. Reinforced Cement Concrete (1:2:4), MAIN WALLS & PARTITION WALLS:- 200 MM/250 MM Thick Cement Brick Work for Main Walls and 125 MM Thick and 75 MM Thick Cement brickwork (1:4) for Flat/Shop/Office Separating Wall and Partition Walls inside the respectively, FLOOR:- Vitrified Floor Tiles for Office and Shop and also for Flat in respect of all room, Verandah, Hall, Kitchen, Bath/Toilet. SKIRTING AND DADO:- Vitrified Floor Tiles, the height not to be exceeded 150 MM High and the Dado Not Exceeding 200 MM High (For Toilet Glazed Titles will be used up to a height of 6 Ft. form Skirting). PLASTERING:- Plastering to external walls will be of 20 MM. thick in 1:5 Cement, Sand and Mortar. Plastering to internal walls will be 15 MM thick in 1:6 Cement, Sand and Mortar and Ceiling will be 10 MM thick in 1:4 Cement, Sand and Mortar. WOODWORK AND JOINERY (FOR FLAT):- 100 MM X 50 MM. Malaysian Xxx Xxxx or equivalent section for Door frame, 32 mm. Thick solid core Wood door, Thickness of the shutter will be 32 mm. Main Door shutter for the OWNER will be made of quality Wood door.
Building Structure. The Building’s exterior walls, roof, elevator shafts, footings, foundations, structural portions of load-bearing walls, structural floors and subfloors and structural columns and beams.
Building Structure. (a) All foundations to include footings, piers, caissons, pilings, grade beams, foundation walls or other building foundation components required to support the entire building structure for a complete waterproof building shell. (b) Columns shall be steel box or pipe columns. (c) All columns, beams, joists, purlins, headers, or other training members to support the roof and roofing membrane.
AutoNDA by SimpleDocs
Building Structure. EXTERIOR
Building Structure. Includes all elements necessary to provide for a completely waterproof Building Shell including but not limited to: a. Concrete foundation and 5" slab-on-grade including all reinforcing steel and wire mesh for 3,000 lb. loading including loading dock if applicable. b. Structural steel columns and beams. c. Wxxx xxxelized glulam roof structure with #420 WMD or equal fiberglass built-up roofing including roof drainage plumbing tied into site storm system. d. Glass, glazing and perimeter roll up or hollow metal doors including normal passage hardware. e. Concrete tilt-up or plaster on metal stud framed exterior walls. f. Exterior painting. 29 -2-
Building Structure. Includes all elements necessary to provide for a completely waterproof Building Shell including but not limited to: a. Concrete foundation and slab on grade including all reinforcing steel and wire mesh including four loading docks. b. Structural steel columns and beams. c. Steel joist and girder second floor system with concrete and metal deck (if multi-story building). x. Xxxx panelized glulam roof structure or steel frame with metal deck and rigid insulation with fiberglass built-up roofing including roof drainage plumbing. e. Glass, glazing and perimeter roll up or hollow metal doors including normal passage hardware. f. Concrete tilt up or plaster on metal stud framed exterior walls.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!