Performance Appraisal The employee's performance will be rated by his/her immediate excluded supervisor. The rater shall discuss the performance appraisal with the employee. The employee shall have the opportunity to provide his/her comments to be attached to the performance appraisal. The employee shall sign the performance appraisal and that signature shall only indicate that the employee has read the performance appraisal. A copy shall be provided the employee at this time.
Performance Appraisals 3201 The Employer shall complete a written appraisal of a nurse's performance at least bi-annually. Upon request, the nurse shall be given an exact copy of the appraisal. 3202 The nurse shall have an opportunity to read such document. 3203 The nurse's signature on such document merely signifies that the contents of the document have been read. 3204 If the nurse disputes the appraisal, she/he may file a reply to the document in accordance with Article 29, and/or she/he may file a grievance under Article 12 of this Agreement.
Office of Inspector General Investigative Findings Expert Review In accordance with Senate Bill 799, Acts 2021, 87th Leg., R.S., if Texas Government Code, Section 531.102(m-1)(2) is applicable to this Contract, Contractor affirms that it possesses the necessary occupational licenses and experience.
INDEPENDENT PRICE DETERMINATION 6.1 By signing and submitting this bid, the Bidder certifies that the prices in this bid have been arrived at independently, without consultation, communication or agreement, for the purpose of restricting competition, as to any matter relating to such prices with any other Bidder or with any competitor; unless otherwise required by law, the prices which have been quoted in this bid have not been knowingly disclosed by the Bidder prior to bid opening directly or indirectly to any other Bidder or to any competitor; no attempt has been made, or will be made, by the Bidder to induce any person or firm to submit, or not to submit, a bid for the purpose of restricting competition.
Performance Adjustment One-twelfth of the annual Performance Adjustment Rate will be applied to the average of the net assets of the Portfolio (computed in the manner set forth in the Fund's Declaration of Trust or other organizational document) determined as of the close of business on each business day throughout the month and the performance period.
CONTRACTOR PERFORMANCE AUDIT The Contractor shall allow the Authorized User to assess Contractor’s performance by providing any materials requested in the Authorized User Agreement (e.g., page load times, response times, uptime, and fail over time). The Authorized User may perform this Contractor performance audit with a third party at its discretion, at the Authorized User’s expense. The Contractor shall perform an independent audit of its Data Centers, at least annually, at Contractor expense. The Contractor will provide a data owner facing audit report upon request by the Authorized User. The Contractor shall identify any confidential, trade secret, or proprietary information in accordance with Appendix B, Section 9(a), Confidential/Trade Secret Materials.
Performance Adjustment Rate Except as otherwise provided in sub-paragraph (e) of this paragraph 3, the Performance Adjustment Rate is 0.02% for each percentage point (the performance of the Portfolio and the Index each being calculated to the nearest .01%) that the Portfolio's investment performance for the performance period was better or worse than the record of the Index as then constituted. The maximum performance adjustment rate is 0.20%. For purposes of calculating the performance adjustment of the portfolio, the portfolio's investment performance will be based on the performance of the retail class. The performance period will commence with the first day of the first full month following the retail class's commencement of operations. During the first eleven months of the performance period for the retail class, there will be no performance adjustment. Starting with the twelfth month of the performance period, the performance adjustment will take effect. Following the twelfth month a new month will be added to the performance period until the performance period equals 36 months. Thereafter the performance period will consist of the current month plus the previous 35 months. The Portfolio's investment performance will be measured by comparing (i) the opening net asset value of one share of the retail class of the Portfolio on the first business day of the performance period with (ii) the closing net asset value of one share of the retail class of the Portfolio as of the last business day of such period. In computing the investment performance of the retail class of the Portfolio and the investment record of the Index, distributions of realized capital gains, the value of capital gains taxes per share paid or payable on undistributed realized long-term capital gains accumulated to the end of such period and dividends paid out of investment income on the part of the Portfolio, and all cash distributions of the securities included in the Index, will be treated as reinvested in accordance with Rule 205-1 or any other applicable rules under the Investment Advisers Act of 1940, as the same from time to time may be amended.
Selection of Reviewing Party; Change in Control If there has not been a Change in Control, any Reviewing Party shall be selected by the Board of Directors, and if there has been such a Change in Control (other than a Change in Control which has been approved by a majority of the Company's Board of Directors who were directors immediately prior to such Change in Control), any Reviewing Party with respect to all matters thereafter arising concerning the rights of Indemnitee to indemnification of Expenses under this Agreement or any other agreement or under the Company's Certificate of Incorporation or Bylaws as now or hereafter in effect, or under any other applicable law, if desired by Indemnitee, shall be Independent Legal Counsel selected by Indemnitee and approved by the Company (which approval shall not be unreasonably withheld). Such counsel, among other things, shall render its written opinion to the Company and Indemnitee as to whether and to what extent Indemnitee would be entitled to be indemnified hereunder under applicable law and the Company agrees to abide by such opinion. The Company agrees to pay the reasonable fees of the Independent Legal Counsel referred to above and to indemnify fully such counsel against any and all expenses (including attorneys' fees), claims, liabilities and damages arising out of or relating to this Agreement or its engagement pursuant hereto. Notwithstanding any other provision of this Agreement, the Company shall not be required to pay Expenses of more than one Independent Legal Counsel in connection with all matters concerning a single Indemnitee, and such Independent Legal Counsel shall be the Independent Legal Counsel for any or all other Indemnitees unless (i) the employment of separate counsel by one or more Indemnitees has been previously authorized by the Company in writing, or (ii) an Indemnitee shall have provided to the Company a written statement that such Indemnitee has reasonably concluded that there may be a conflict of interest between such Indemnitee and the other Indemnitees with respect to the matters arising under this Agreement.
Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.
Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.