CONTRACTOR QUALITY CONTROL Sample Clauses

CONTRACTOR QUALITY CONTROL. The Government will evaluate the Contractor’s performance under this contract and respective task orders in accordance with the Surveillance Activity Checklist, Attachment 3. The principal evaluator of Contractor work quality is the Government COR/ACOR in coordination with TPOC/Alternate TPOC (ATPOC). This plan is primarily focused on what the Government must do to ensure that the Contractor has performed in accordance with the performance standards. It defines how the plan will survey, observe, test, sample, evaluate, and document the Contractor’s performance standards identified in this SOW and resulting T/Os. 3.2.9.1 The Contractor shall develop and maintain an effective ID/IQ quality control program (QCP) to ensure services are performed in accordance with this SOW. The Contractor shall develop and implement procedures to identify, prevent, and ensure non-recurrence of defective services. The Contractor’s quality control program is the means by which the Contractor assures that work complies with the requirement of this SOW and resulting future T/Os. 3.2.9.2 The Contractor shall monitor cost, schedule and performance data for each awarded T/O. The Contractor shall make its monitoring method available to the Government no later than 30 calendar days after ID/IQ contract award as part of its QCP. The Contractor shall take immediate corrective action for any negative variances and provide specific corrective action details to the Government. 3.2.9.3 The Contractor shall maintain records of inspection that are available to the Government throughout ID/IQ contract performance and for the period after ID/IQ contract completion until final settlement of any claims under this contract. The Contractor shall maintain the inspection schedule and inspection plan as part of the record of inspection. 3.2.9.4 The Contractor shall permit the PCO or COR authorized access to all work areas, records, and data used in the performance of contracted services. The Contractor shall provide support, and not interfere with the PCO, CORs, state, federal, and other designate personnel in the performance of their official duties. Access shall be provided as soon as possible, but not to exceed one (1) workday after the request. The Contractor shall notify the Government immediately when personnel/agencies other than those specifically designated request access.
AutoNDA by SimpleDocs
CONTRACTOR QUALITY CONTROL. Contractor Quality Control (CQC) is the means by which the Contractor ensures that the work, to include that of subcontractors and suppliers, complies with the requirements of the contract. The Contractor is responsible for quality control and shall establish and maintain an effective quality control system for both on- and off-site activities. The quality control system shall consist of personnel, plans, procedures, and organization necessary to produce an end product that complies with governing regulations and contract task order requirements. The Contractor is required to prepare a Contractor Quality Control Plan (CQC Plan) for each task order, specific to the work required under that task order and operations will be permitted to begin only after Government acceptance of the CQC Plan or acceptance of an interim plan applicable to the particular feature of work to be started. The CQC Plan shall identify the personnel, plans, procedures, and organization for the work to be completed on a specific task order to effectively demonstrate how the Contractor will ensure quality deliverables. The Contractor shall maintain current records providing factual evidence that the required quality control activities and/or tests have been performed. The Contractor shall notify the COR and KO as soon as possible of any detected noncompliance of work performed with established quality control criteria. The nonconformance report shall include the cause of the nonconformance, proposed corrective action(s), and effect of the nonconformance. Additional Quality Control requirements are included in Attachment 9 - NWK Supplement for Contractor Quality Control Plans for Remedial Actions, which is listed as an attachment in Section J. The Government reserves the right to require the Contractor to resubmit any services, supplies, or materials found not to comply with the contract.
CONTRACTOR QUALITY CONTROL. Hot/Warm Mix Asphalt for testing purposes will be sampled at a location in the process as approved by the District Engineer or their Designee. Contractor shall arrange for calibration samples to be provided to the Testing Agency (District Laboratory) so that each ignition oven can be calibrated to perform AASHTO T 308 in accordance with the State Materials Bureau’s Ignition Oven Calibration Factors Procedures. This will be incidental to the Hot Mix Asphalt. At no cost to NMDOT, Contractor is responsible to obtaining all necessary and applicable testing data for production / process control and share the results with NMDOT Project Staff. The following are the MINIMUM TESTING REQUIREMENTS FOR HOT MIX ASPHALT: Roadway Density Agency Testing 1 per 300 tons Roadway Density Independent Assurance 2 per project min. Gradation Agency Testing 1 per day Gradation Independent Assurance 2 per project min. Acceptance for hot mix asphalt density will be based on roadway densities utilizing a portable nuclear densometer. Section 702Construction Traffic Control Devices Exclude: Section 702.2.5 Temporary Signal Span Section 702.3.1.2 Temporary Signal Span Section 704Pavement Markings Exclude Section 704.2.5 Hot Thermoplastic Pavement Markings The contractor shall be responsible for securing water for operations. The cost of water shall be incidental to repaving items. The contractor shall abide by the water laws of the state and the rules and regulations of the Office of the State Engineer when appropriating water. Hot/Warm mix asphalt shall be furnished utilizing existing NMDOT hot/warm mix designs or designed by a commercial laboratory. In either case, designs shall be approved by the State Materials Laboratory of the NMDOT. Asphalt shall be of the Type PG 76-22 or PG 70-22, as specified by individual purchase order line item number selection. For the purposes of this Price Agreement, the base grade PG Binder shall the minimum PG binder used in the NMDOT approved HMA/WMA mix design. Use of blending charts with 15% of RAP Mix designs or less shall not be permitted. All mix designs provided for this Price Agreement shall use 15% RAP or less. Utilization of Item 073 for hauling of new hot mix asphalt for Item 029 or 030 will be measured on an hourly basis when material is delivered directly from the plant to the machine. Hauling time shall include sufficient time for trucks to tare and stage at the plant, and sufficient time after the trucks last load of the day to ret...
CONTRACTOR QUALITY CONTROL. 8.1 Contractor Quality Control (CQC) is the means by which the Contractor ensures that all work, including that of subcontractors, complies with the contract requirements. The Contractor is responsible for quality control and shall establish an effective quality control system. The Contractor shall establish and maintain a complete quality control plan in accordance of FAR52.246-1,
CONTRACTOR QUALITY CONTROL. The contractor shall perform Quality Control (QC) testing in accordance with the specifications and as specified herein. The contractor shall submit a Quality Control Plan (QC Plan) to the engineer for approval that includes all items listed in Section 2.0, prior to beginning work.
CONTRACTOR QUALITY CONTROL. Contractor is responsible for controlling the quality of the work as set forth in the Contract Documents.
CONTRACTOR QUALITY CONTROL. CQC is the means by which the Contractor ensures that the work, to include that of subcontractors and suppliers, complies with the requirements of the contract. The Contractor is responsible for QC and shall establish and maintain an effective QC system for both on- and off-site activities. The QC system shall be documented in the Contractor’s QC Plan. The Contractor is not permitted to begin operations until after the Government’s acceptance of their CQC Plan or acceptance of an interim plan applicable to the particular feature of work to be started. . The Contractor shall maintain current records providing factual evidence that the required QC activities and/or tests have been performed according to their QC Plan. The Contractor shall notify the KO as soon as possible of any detected noncompliance of work performed with established QC criteria. The nonconformance report shall include the cause of the nonconformance, proposed corrective action(s), and effect of the nonconformance. Additional QC requirements are included in the “NWK Supplement for Contractor Quality Control Plans for Remedial Actions”, which is included an attachment in Section J of this solicitation. Section E - Inspection and Acceptance INSPECTION AND ACCEPTANCE TERMS Supplies/services will be inspected/accepted at: XXXX INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY 0001 Destination Government Destination Government 0002 Destination Government Destination Government 0003 Destination Government Destination Government 0004 Destination Government Destination Government 0005 Destination Government Destination Government 0006 Destination Government Destination Government CLAUSES INCORPORATED BY REFERENCE 52.246-4 Inspection Of Services--Fixed Price AUG 1996 52.246-5 Inspection Of Services Cost-Reimbursement APR 1984 52.246-12 Inspection of Construction AUG 1996 Section F - Deliveries or Performance DELIVERY INFORMATION CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC / CAGE 0001 POP 24-AUG-2020 TO 23-AUG-2023 N/A USACE, KANSAS CITY + XXX XXXXXXXXX PM-ED ROOM 463 000 X 00XX XXX XXXX XXXXXX XXXX XX 00000-2896 816-389-3897 FOB: Destination 966419 0002 POP 24-AUG-2020 TO 23-AUG-2023 N/A (SAME AS PREVIOUS LOCATION) FOB: Destination 966419 0003 POP 24-AUG-2023 TO 23-AUG-2025 N/A (SAME AS PREVIOUS LOCATION) FOB: Destination 966419 0004 POP 24-AUG-2023 TO 23-AUG-2025 N/A (SAME AS PREVIOUS LOCATION) FOB: Destination 966419 0005 POP 25-AUG-2025 TO 24-FEB-2026 N/A (SAME AS PREVIOUS LOCATION) FOB: Destinat...
AutoNDA by SimpleDocs
CONTRACTOR QUALITY CONTROL. The Contractor shall establish and maintain a complete Quality Control (QC) program in accordance with “CONTRACTOR QUALITY CONTROL,” in Section E. Contractor performed inspections are independent of those performed by the Government. The Contractor shall perform the inspections prior to requesting acceptance of the work by the Government and shall provide logs that document each weekly or daily inspection, including, but not limited, comments concerning problems and solutions, task and personnel, project progress, and reviewing and editing efforts. The Contractor will provide the Government access to the logs upon request at any time during the course of a Task Order and the Contractor shall deliver them within five (5) working days of the request. The Contractor’s Project Director and the QC inspector shall attend pre-performance meetings. The QC inspector shall also attend meetings with the Contracting Officer and other Government personnel to resolve quality considerations and problems that may arise in the course of the work.
CONTRACTOR QUALITY CONTROL. (QC) a. The Contractor shall establish and maintain a Quality Control Program in accordance with the FAR 52.246-4, "INSPECTION OF SERVICES - FIXED-PRICE" clause, E2, to ensure that the work performed under this contract conforms to the contract requirements. The Contractor shall submit to the Contracting Officer a General Quality Control Plan (QCP) as part of the Technical Proposal. b. The Contractor's QCP shall provide top Contractor management with an effective and efficient means of identifying and correcting problems throughout the entire scope of operations. c. The QCP shall include: (1) A description of the Contractor's quality control system. The system must cover all contract services, specify work to be inspected on either a scheduled or unscheduled basis, and describe how inspections are to be conducted. (2) The name(s) and qualifications of the individual(s) responsible for performing the quality control inspections, and the extent of their authority. (3) Provisions for recording the results of inspections and for recording corrective action taken. (4) Provisions to update and revise the QCP during the performance of the contract.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!