{"component": "clause", "props": {"groups": [{"samples": [{"hash": "ctaYdJO9X1M", "uri": "/contracts/ctaYdJO9X1M#demising-partitions", "label": "Lease Agreement (Silicon Entertainment Inc /Ca/)", "score": 18.0, "published": true}, {"hash": "3BiP9Z84YNa", "uri": "/contracts/3BiP9Z84YNa#demising-partitions", "label": "Lease Agreement (Silicon Entertainment Inc /Ca/)", "score": 18.0, "published": true}], "snippet": "All demising partitions between Tenant's space and adjacent space must be fully sheathed using 5/8\" Type X gypsum board, taped and finished, from floor to structure above.", "size": 2, "snippet_links": [{"key": "adjacent-space", "type": "definition", "offset": [51, 65]}, {"key": "gypsum-board", "type": "clause", "offset": [107, 119]}], "hash": "832bb6ee6189484e2365e86b26e53b28", "id": 1}, {"samples": [{"hash": "jYlkAErKsg5", "uri": "/contracts/jYlkAErKsg5#demising-partitions", "label": "Lease Agreement (NationsHealth, Inc.)", "score": 18.0, "published": true}], "snippet": "Shall be constructed to extend from floor slab to underside of roof deck or steel beam above. Construct with fire rated code 5/8\" type X gypsum wallboard on each side, sound batt insulation in 3 5/8\" metal studs (24\" on center) taped and spackled with vinyl base. Fire rated caulk to be applied all around. Each side of the partition to be painted with two (2) coats of flat paint and contains a 4\" carpet base. Any other unfinished concrete or masonry walls or columns are to be furred with _____ gypsum wallboard over 1 1/2\" studs at 24\" on center. Insulation is to be provided per the design energy calculations.", "size": 2, "snippet_links": [{"key": "to-extend", "type": "clause", "offset": [21, 30]}, {"key": "floor-slab", "type": "clause", "offset": [36, 46]}, {"key": "roof-deck", "type": "clause", "offset": [63, 72]}, {"key": "masonry-walls", "type": "clause", "offset": [445, 458]}, {"key": "design-energy", "type": "definition", "offset": [588, 601]}], "hash": "6d85b207c4e077b142ea8c1e6cb2cd75", "id": 2}, {"samples": [{"hash": "f7jjBMw9mOS", "uri": "/contracts/f7jjBMw9mOS#demising-partitions", "label": "Lease (Silicon Entertainment Inc /Ca/)", "score": 18.0, "published": true}], "snippet": "Landlord shall install metal wall studs, 16\" on center, between all leased premises. Where rated walls are required between Leased Premises and service/exit corridors Landlord shall install 5/8\" fire code gypsum board from the floor to the roof deck on both Landlord and Tenant sides, along demising partitions separating Tenant from service/exit corridors.", "size": 1, "snippet_links": [{"key": "landlord-shall", "type": "clause", "offset": [0, 14]}, {"key": "leased-premises", "type": "clause", "offset": [68, 83]}, {"key": "fire-code", "type": "clause", "offset": [195, 204]}, {"key": "gypsum-board", "type": "clause", "offset": [205, 217]}, {"key": "roof-deck", "type": "clause", "offset": [240, 249]}, {"key": "landlord-and-tenant", "type": "clause", "offset": [258, 277]}], "hash": "2b8c08bbedaac7ecaceba5cfd5af01dd", "id": 3}, {"samples": [{"hash": "f8Ey2hfVR5M", "uri": "/contracts/f8Ey2hfVR5M#demising-partitions", "label": "Industrial Lease (Intellicell Corp)", "score": 18.0, "published": true}], "snippet": "Those walls that separate the rentable space from one tenant to another. These one (1) hour fire rated walls shall be installed from floor to underside of roof deck and shall include 6\"-18\" gauge metal studs 12\" o/c with 5/8\" type \"X\" wall board, taped, spackled, and painted white. 1/2\" plywood will be applied at a height of 4' and painted white.", "size": 1, "snippet_links": [{"key": "rentable-space", "type": "definition", "offset": [30, 44]}, {"key": "roof-deck", "type": "clause", "offset": [155, 164]}], "hash": "6b9cf6ad996620bdd59ada8d993d57e7", "id": 4}, {"samples": [{"hash": "eLMzzPUkD2V", "uri": "/contracts/eLMzzPUkD2V#demising-partitions", "label": "Lease Agreement (Peerless Systems Corp)", "score": 21.0, "published": true}], "snippet": "2-1 2\u201d x 25 gauge metal studs at 24\u201d on center, slab to slab with one layer of 5/8 thick type \u201cX\u201d Gypsum wall board from slab to slab and one layer of 5/8\u201d thick type \u201cX\u201d Gypsum wall board from slab to 6\u201d above grid. Provide 2-1/2\u201d thick full batt sound insulation. All joints are to be taped, visible joints to be spackled and sanded ready for painting. (Allowance \u2014 One-half (1/2) of demising partitions shall be included in the interior partition allowance between unrelated tenants as required.)\n2-1 2\u201d x 25 Gauge metal studs at 24\u201d on center, with 5/8\u201d thick type \u201cX\u201d Gypsum wall board to 6\u201d above grid on both sides, with 2-1/2\u201d thick full batt insulation. (Finished wall height 9\u2019-6\u201d). All joints are to be taped, visible joints to be spackled and sanded ready for painting.", "size": 1, "snippet_links": [{"key": "sound-insulation", "type": "clause", "offset": [248, 264]}, {"key": "interior-partition", "type": "clause", "offset": [431, 449]}, {"key": "as-required", "type": "clause", "offset": [486, 497]}, {"key": "both-sides", "type": "definition", "offset": [611, 621]}, {"key": "wall-height", "type": "definition", "offset": [673, 684]}], "hash": "f145c446aedf7c05c80f1341dab2b13d", "id": 5}, {"samples": [{"hash": "9840MkN1G6m", "uri": "/contracts/9840MkN1G6m#demising-partitions", "label": "Lease (SoulCycle Inc.)", "score": 26.4729637235, "published": true}], "snippet": "Per an agreed to location as noted on Exhibit A, 8/22/12, \u2587\u2587\u2587\u2587\u2587 Street entry location. Landlord will provide a new glass and steel entry door using similar construction methods and materials as that of the existing first floor facade, within sixty (60) days of the Commencement Date, but not as a condition to the Commencement Date. See Exhibit A. \u2022 Landlord to construct interior demising walls per on agreed to location (as noted on Exhibit A).", "size": 1, "snippet_links": [{"key": "agreed-to", "type": "clause", "offset": [7, 16]}, {"key": "exhibit-a", "type": "clause", "offset": [38, 47]}, {"key": "provide-a", "type": "definition", "offset": [101, 110]}, {"key": "methods-and-materials", "type": "clause", "offset": [169, 190]}, {"key": "first-floor", "type": "definition", "offset": [215, 226]}, {"key": "the-commencement-date", "type": "clause", "offset": [261, 282]}, {"key": "see-exhibit", "type": "clause", "offset": [333, 344]}, {"key": "landlord-to-construct", "type": "clause", "offset": [350, 371]}, {"key": "demising-walls", "type": "clause", "offset": [381, 395]}], "hash": "73fc43f523a884be616623ca8829c8a1", "id": 6}, {"samples": [{"hash": "c91SLkKhnO5", "uri": "/contracts/c91SLkKhnO5#demising-partitions", "label": "Lease Agreement (Medicines Co /De)", "score": 21.0, "published": true}], "snippet": "Building standard public corridor partitions shall be installed on the 1st floor.", "size": 1, "snippet_links": [{"key": "building-standard", "type": "definition", "offset": [0, 17]}], "hash": "84b06d221a3e02a2f0775db5e080989a", "id": 7}, {"samples": [{"hash": "dYkRJqo82Vo", "uri": "/contracts/dYkRJqo82Vo#demising-partitions", "label": "Lease Agreement (Play Co Toys & Entertainment Corp)", "score": 18.0, "published": true}], "snippet": "Demising partitions are not load bearing and Tenant may not hang fixtures from them. Should Tenant require structure and/or backing to accommodate the loading of Tenant's wall hung fixture, said request shall be in writing to Landlord for approval. Additional structure and backing shall be furnished and installed by Landlord at Tenant's expense. No drywall shall be placed on demising partitions above 1 2'-0\" without Landlord's specific approval. Above 1 2'-0\", Tenant may, subject to Landlord's prior written approval, continue with wire mesh for security purposes if so indicated on Tenant's construction drawings. Tenant may, with Landlord's approval, also install drywall to a higher level if openings of sufficient size are provided to assure that the smoke venting system provided by Landlord functions as designed.", "size": 1, "snippet_links": [{"key": "tenant-may", "type": "definition", "offset": [45, 55]}, {"key": "should-tenant", "type": "definition", "offset": [85, 98]}, {"key": "of-tenant", "type": "clause", "offset": [159, 168]}, {"key": "in-writing", "type": "clause", "offset": [212, 222]}, {"key": "to-landlord", "type": "clause", "offset": [223, 234]}, {"key": "for-approval", "type": "definition", "offset": [235, 247]}, {"key": "by-landlord", "type": "clause", "offset": [315, 326]}, {"key": "at-tenant", "type": "definition", "offset": [327, 336]}, {"key": "without-landlord", "type": "definition", "offset": [412, 428]}, {"key": "specific-approval", "type": "definition", "offset": [431, 448]}, {"key": "subject-to", "type": "definition", "offset": [477, 487]}, {"key": "prior-written-approval", "type": "definition", "offset": [499, 521]}, {"key": "construction-drawings", "type": "clause", "offset": [597, 618]}, {"key": "higher-level", "type": "definition", "offset": [684, 696]}, {"key": "venting-system", "type": "definition", "offset": [766, 780]}], "hash": "c6f1bd18c1730ff0aa109a4edbcc5f9a", "id": 8}, {"samples": [{"hash": "efjzm04D1ZF", "uri": "/contracts/efjzm04D1ZF#demising-partitions", "label": "Lease Agreement (A-Mark Precious Metals, Inc.)", "score": 27.726899384, "published": true}], "snippet": "Furnish and install partitions with 2\u00bd\" x 25 gauge metal studs at 24\" on center, slab to slab, at floors above the ground floor, with one layer of 5/8\" thick type \"X\" drywall on each side. Provide 2\u00bd\" thick full batt sound insulation, seismic bracing as required, and control joints and control joint sealants in partitions, as recommended by gypsum wall board manufacturer. All joints are to be taped; visible joints to be spackled and sanded ready for painting. Caulk joint between bottom of wall board and the floor.", "size": 1, "snippet_links": [{"key": "furnish-and-install", "type": "definition", "offset": [0, 19]}, {"key": "ground-floor", "type": "clause", "offset": [115, 127]}, {"key": "sound-insulation", "type": "clause", "offset": [217, 233]}, {"key": "seismic-bracing", "type": "clause", "offset": [235, 250]}, {"key": "as-required", "type": "clause", "offset": [251, 262]}, {"key": "control-joints", "type": "clause", "offset": [268, 282]}, {"key": "joint-sealants", "type": "clause", "offset": [295, 309]}], "hash": "c793e8c133ee0d6bce1184b3cad31640", "id": 9}, {"samples": [{"hash": "f7jjBMw9mOS", "uri": "/contracts/f7jjBMw9mOS#demising-partitions", "label": "Lease (Silicon Entertainment Inc /Ca/)", "score": 18.0, "published": true}], "snippet": "Demising partitions are not load bearing and Tenant may not hang fixtures from them. Should Tenant require structure and/or backing to accommodate the loading of Tenant's wall hung fixtures, said request shall be in writing to landlord for approval. Additional structure and backing shall be furnished and installed by Tenant at Tenant's Expense. Tenant shall install drywall, taped and spackled on demising partitions between tenants. No drywall shall be placed on demising partitions above 12'-0\" without Landlord's specific approval. Above 12'-0\" the Tenant may, subject to Landlord's prior written approval, continue with wire mesh for security purposes if so indicated on Tenant's construction drawings. The Tenant, upon Landlord's approval, may also install drywall to a higher level if openings of sufficient size are provided to assure that the smoke venting system provided by the Landlord functions as designed - see Tenant Handbook for specific requirements.", "size": 1, "snippet_links": [{"key": "tenant-may", "type": "definition", "offset": [45, 55]}, {"key": "should-tenant", "type": "definition", "offset": [85, 98]}, {"key": "of-tenant", "type": "clause", "offset": [159, 168]}, {"key": "in-writing", "type": "clause", "offset": [213, 223]}, {"key": "to-landlord", "type": "clause", "offset": [224, 235]}, {"key": "for-approval", "type": "definition", "offset": [236, 248]}, {"key": "by-tenant", "type": "clause", "offset": [316, 325]}, {"key": "at-tenant", "type": "definition", "offset": [326, 335]}, {"key": "tenant-shall", "type": "clause", "offset": [347, 359]}, {"key": "without-landlord", "type": "definition", "offset": [499, 515]}, {"key": "specific-approval", "type": "definition", "offset": [518, 535]}, {"key": "the-tenant", "type": "clause", "offset": [550, 560]}, {"key": "subject-to", "type": "definition", "offset": [566, 576]}, {"key": "prior-written-approval", "type": "definition", "offset": [588, 610]}, {"key": "construction-drawings", "type": "clause", "offset": [686, 707]}, {"key": "upon-landlord", "type": "definition", "offset": [721, 734]}, {"key": "higher-level", "type": "definition", "offset": [777, 789]}, {"key": "venting-system", "type": "definition", "offset": [859, 873]}, {"key": "the-landlord", "type": "clause", "offset": [886, 898]}, {"key": "tenant-handbook", "type": "clause", "offset": [927, 942]}, {"key": "specific-requirements", "type": "clause", "offset": [947, 968]}], "hash": "c6d81adb34c8eb18d901e0c88cb49018", "id": 10}], "next_curs": "ClwSVmoVc35sYXdpbnNpZGVyY29udHJhY3RzcjgLEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IhxkZW1pc2luZy1wYXJ0aXRpb25zIzAwMDAwMDBhDKIBAmVuGAAgAA==", "clause": {"parents": [["general-provisions", "GENERAL PROVISIONS"], ["building-shell-work-within-and-around-the-leased-premises", "Building Shell Work Within and Around the Leased Premises"], ["tenant-handbook", "Tenant  Handbook"], ["term", "Term"], ["miscellaneous", "Miscellaneous"]], "title": "Demising Partitions", "size": 17, "children": [], "id": "demising-partitions", "related": [["walls", "Walls", "Walls"], ["interior", "Interior", "Interior"], ["exterior", "Exterior", "Exterior"], ["common-area", "Common Area", "Common Area"], ["roof", "Roof", "Roof"]], "related_snippets": [], "updated": "2025-07-07T12:37:55+00:00"}, "json": true, "cursor": ""}}