Design and Installation. A standard minimum of one (1) store front shall be designed by the Project Architect and installed by Landlord consisting of a minimum of one (1) single door with cylinder lock. Landlord may elect to provide a double-entry door, at Landlord’s sole discretion, predicated on the square footage of the Premises. 15953353_v12
Design and Installation. (a) The design for the Solar Facility will be presented to you prior to installation. You will have five (5) business days following this presentation to request a change or cancel this Lease pursuant to Section 12(e). Otherwise, you will be deemed to have approved the Solar Facility design. With your written, deemed, or verbal approval, Solar Facility installation may begin at any time.
(b) If you wish to change the design or installation process, Sunrun will use commercially reasonable efforts to accommodate your request.
(c) If an obligation excluded from this Lease in Section 20 must be performed in order to properly effect the installation of the Solar Facility, you agree to contract separately, and at your own expense, with a contractor who has been designated by or approved by Sunrun to perform such obligation. In this instance, Sunrun will not unreasonably withhold such approval.
(d) You agree to cooperate with Sunrun and assist Sunrun in obtaining any permits needed, including the NEM Service application in Section 5(a). You agree to complete and return to Sunrun and/or its representatives, as appropriate, all applicable rebate documentation, and, where applicable, Renewable Energy Credit, documentation upon request and following the In-Service Date. If you do not return the rebate or Renewable Energy Credit documentation, Sunrun may invoice you for the Final Rebate amount (as defined in Section 4(a)(iii)).
(e) For the Initial Term and any Renewal Terms you agree to maintain the Property, at your expense, such that the Solar Facility retains shading conditions present at the time of Installation.
(f) Sunrun requires its contractors to employ licensed personnel whenever required by applicable law, regulation or code.
(g) Sunrun, its contractors and agents shall at the end of each business day keep the Property reasonably free from waste materials or rubbish caused by their operations. Prior to the In-Service Date, Sunrun and its agents shall remove all of their tools, construction/installation equipment, machinery, waste materials and rubbish from and around the Property.
(h) Subject to the exclusions set forth in Section 20, Sunrun will return your Property to a condition similar to its original condition, provided that you notify Sunrun in writing or by e-mail of any deficiencies in restoration within five (5) business days of the municipal building inspector approval of the Solar Facility.
Design and Installation. (a) Description of the Significant Materials to be Used and
Design and Installation. 3.1 Clauses 5 and 6 of the Standard Terms and Conditions shall apply.
3.2 Installation Charges shall be invoiced in in accordance with clause 13 of the Standard Terms and Conditions.
Design and Installation. All decisions to be made in connection with the manner of design and installation of the Water Main Extension, the type of materials to be used, and the maintenance thereof shall be and shall so remain at the exclusive discretion and under the sole control of the District.
Design and Installation. The basic design of the Equipment shall comply with the Design and Operational Standards set forth in Exhibit B, attached hereto and incorporated herein by this reference. All of the construction and installation work for Equipment shall be performed at Licensee's sole cost and expense and in a good and workmanlike manner and promptly completed.
Design and Installation. [***] Confidential treatment has been requested for the bracketed portions. The confidential redacted portion has been omitted and filed separately with the Securities and Exchange Commission.
(a) Description of the Significant Materials to be
Design and Installation of System and all piping completed following LG’s published guidelines and using LG’s LATS to determine piping size and lengths.
Design and Installation. Company will design, procure, and install the Equipment pursuant to the requirements of the SOW.
Design and Installation. Developer shall design the PV System in accordance with Good Engineering Practice, shall consult with and receive input from Host with respect to integration of the PV System with the Host’s facilities and submit the final design for Host’s approval, not to be unreasonably withheld or delayed, with a copy to CVEC. In the case of a Battery Energy Storage System, Developer shall submit a fire prevention plan to Host’s fire chief and obtain his or her approval. Developer shall furnish all supplies, materials, labor, tools, equipment and other services necessary for installation of the PV System. As soon as practicable after the Effective Date, Developer shall provide Host and CVEC an updated schedule for design, permitting, equipment procurement, commencement of construction and commissioning of the PV System, indicating milestones and durations of activities. Subject to delays excused hereunder, or the failure of the Host to comply with its obligations hereunder, Developer shall commence construction of the PV System no later than the Outside Construction Commencement Date and will proceed diligently and continuously thereafter until completion, but in no event shall the installation be completed later than the Outside Commercial Operation Date. Developer shall install the PV System in accordance with Good Engineering Practice, all Applicable Legal Requirements, applicable contractor, subcontractor and vendor warranties or guarantees, manufacturer’s warranties, instruction and specifications, as further identified in the Common Technical Specifications set forth in Exhibit E, applicable requirements of the insurance policies maintained by Host with respect to the PV System, and the terms of this Agreement.