ELECTRONIC PROTECTIONS. (a) Adequate protection is to be incorporated under no load conditions e.g. when the lamp is removed and the system is switched ON. (b) The system should have protection against battery overcharge and deep discharge conditions. (c) Fuses should be provided to protect against battery overcharge and deep discharge conditions. (d) A blocking diode should be provided as a part of the electronics to prevent reverse flow of current throughout the PV module(s), in case such diode is not provided with the solar module(s). (e) Full protection against open circuit accidental short circuit and reverse polarity should be provided.
Appears in 2 contracts
Samples: Rate Contract, Rate Contract
ELECTRONIC PROTECTIONS. (a) Adequate protection is to be incorporated under no load conditions e.g. when the lamp is removed and the system is switched ON.
(b) . • The system should have protection against battery overcharge and deep discharge conditions.
(c) . • Fuses should be provided to protect against battery overcharge and deep discharge conditions.
(d) . • A blocking diode should be provided as a part of the electronics to prevent reverse flow of current throughout the PV module(s), in case such diode is not provided with the solar module(s).
(e) . • Full protection against open circuit accidental short circuit and reverse polarity should be provided.
Appears in 1 contract
Samples: Construction Contract
ELECTRONIC PROTECTIONS. (a) Adequate protection is to be incorporated under no load conditions (e.g. when the lamp is removed and the system lantern is switched ON).
(b) The system Battery cut offs & reconnections should have protection be provided to protect it against battery overcharge and deep discharge conditions.
(c) Fuses A fuse should be provided to protect against battery overcharge and deep discharge short circuit conditions.
(d) A blocking diode, preferably a Schottky diode should be provided as a part of the lantern electronics to prevent reverse flow of current throughout through the PV module(s), module in case such a diode is not provided with the solar module(s)module itself.
(e) Full protection against open circuit circuit, accidental short circuit and reverse polarity should be provided.
Appears in 1 contract
Samples: Rate Contract
ELECTRONIC PROTECTIONS. (a) Adequate protection is to be incorporated under no load conditions e.g. when the lamp is lamps are removed and the system is switched ON.
(b) The system should have protection against battery overcharge and deep discharge discharg conditions.
(c) Fuses should be provided to protect against battery overcharge and deep discharge short circuit conditions.
(d) A blocking diode should be provided as a part of the electronics to prevent reverse flow of current throughout the PV module(s), in case such diode is not provided with the solar module(s).
(e) Full protection against open circuit accidental short circuit and reverse polarity should be provided.