Fire Fighting System Sample Clauses

Fire Fighting System. Fire-fighting system for substation including transformer & reactor shall conform to CEA (Measures Relating to Safety & Electric Supply) Regulations. Further, adequate water hydrants and portable fire extinguishers shall be provided in the substations. The main header of firefighting system shall be suitable for extension to bays covered under the future scope; necessary piping interface in this regard shall be provided. At existing substations, the fire-fighting systems as available shall be extended to meet the additional requirements.
AutoNDA by SimpleDocs
Fire Fighting System. Fire-fighting system for substation including transformer and reactor shall conform to CEA (Measures Relating to Safety and Electric Supply) Regulations, 2023 as amendment time to time. Further, adequate water hydrants and portable fire extinguishers shall be provided in the substations. The main header of firefighting system shall be suitable for extension to bays covered under the future scope; necessary piping interface in this regard shall be provided. Optical Beam type heat detection for GIS hall fire protection system shall be provided for all the GIS halls. At existing substations, the fire-fighting systems, as available, shall be augmented/ extended to meet the additional requirements.
Fire Fighting System. (1) The Licensee shall install fire Alarm System of make specified by the Licensor, at his own cost. The Licensee shall take tap-off for down type sprinklers with installation of make specified by the Licensee, under the supervision of Engineers of the Licensor. (2) The Licensee, shall execute the interior works or any alterations, modification, permitted under this Agreement, without altering/ tampering with the firefighting systems as installed by the Licensor. However, any modifications/additions/alterations to the existing firefighting system shall be made by the Licensee with the prior written approval of the Licensor and by providing alternative and standby firefighting system in the Building. Any lapse/violation/negligence on the part of the Licensee or its contractors / agents during any such interior works or additions/modifications/alterations resulting in any kind of hazard or fire in the Licensed Premises/ the said Building, loss of life/ property including third party, damage to the Licensed Premises / said Building structure etc. and all financial and legal consequences arising there from shall be the sole responsibility of the Licensee and the Licensee shall not impose any legal and financial liability on the Licensor and shall keep the licensor indemnified. (3) Before vacating the licensed premises the Licensee shall realign and restore modifications/additions/alterations made in the firefighting system at its own cost.
Fire Fighting System. At existing substations, the fire-fighting systems as available shall be extended to meet the additional requirements.
Fire Fighting System. Fire system requirements depend on the applicable local codes and the requirements of the Owner’s insurance company. Wärtsilä’s standard plant is equipped with the following detection and protection devices. If local codes or the insurance company requirements mandate additional equipment or material, it can be offered at additional cost. This information is confidential and proprietary to Wärtsilä. Page: 36 of 81 Project name: Project number: Quotation number: Created by: Document Id: Document creation date: Power Supply Upgrade. LGL P0900329 Q0900869 MNO002 August 25, 2009 1 Foam systems for tanks 1 Engine’s + Fuel treatment water mist systems 1 Hydrants and hose cabinets inside
Fire Fighting System. Fire-fighting system for substation including transformer and reactor shall conform to CEA (Measures Relating to Safety and Electric Supply) Regulations, 2023 as amendment time to time.
Fire Fighting System. Such other common parts, areas and equipments, installations, fixtures and fittings and spaces in or about the said building as are necessary for passage to the user and occupancy of the unit in common and such other common facilities as may be prescribed from time to time
AutoNDA by SimpleDocs
Fire Fighting System. The Concessionaire shall design and implement a comprehensive fire fighting system in accordance with CPWD and NBC norm.
Fire Fighting System. The Landlord shall provide in the leased area the general fire fighting and security systems conforming to the requirements of the laws and regulations of the State, and provide the daily maintenance and matching connection points for the fire fighting and security equipment installed or furnished in the leased are and the ancillary area by the Tenant independently. The Tenant shall build within the leased area including but not limited to the evacuation route, fire fighting equipment, and alarm system.
Fire Fighting System. The design shall be prepared for the whole system, including connection to a seawater pumping station, etc. in accordance with Applicable Law, Permits and Good Industry Practice. The firefighting system shall cover the whole Port Facility area, including all terminal facilities. The system should be extendable for future extension areas. Additional pumping stations shall be built, if required by the extension of the network. Seawater drawn from a special pumping station with submersible borehole pumps shall feed the fire fighting system. The whole fire fighting system, including all devices and equipment, has to be seawater resistant. The number and location of under floor and stand post hydrants and hose connections shall be determined by the Concessionaire for approval by the Independent Engineer/Grantor, but shall not be spaced further apart than 90 m or more than 45 m from a dead end. The whole system shall stay flooded under a constant pressure head in order to detect leaks within the system and for reasons of quick availability of firefighting water in case of fire. The firefighting system shall be dimensioned to cover a maximum pressure head within potable water system of 16 bar. Pressure head at supply point shall be 5 bar at maximum.