Intensity of light emitted Sample Clauses

Intensity of light emitted. 6.1. The intensity of light emitted by each of two samples shall be not less than the minimum intensity and not greater than the maximum intensity specified in paragraphs 6.2. and 6.3. The intensity shall be measured in relation to the axis of reference in the directions shown below (expressed in degrees of angle with the axis of reference). Test points are given for a lamp mounted on the left side of the vehicle, the L designations become R designations for a lamp mounted on the right side of the vehicle.
AutoNDA by SimpleDocs
Intensity of light emitted. 6.1. The intensity of the light emitted by each of the two samples shall be not less than the minima and not greater than the maxima specified below and shall be measured in relation to the axis of references in the directions shown below (expressed in degrees of angle with the axis of reference).
Intensity of light emitted. 6.1. The light emitted by each of the two devices supplied shall be in the reference axis, of not less than the minimum intensity and of not more than the maximum intensity specified below: Maximum luminous intensity in cd when used as Lamp (single) marked "D" Minimum luminous (paragraph intensity in cd Single lamp 4.2.2.6.)
Intensity of light emitted. 6.1. The light emitted by each of the two lamps supplied must be in the case of direction indicators of categories 1, 1a, 1b, 2a, 2b, in the reference axes, in the case of direction indicators of categories 5 or 6 in direction A according to Annex 1 of not less than the minimum intensity and of not more than the maximum intensity specified below: Direction indicator of category Minimum luminous intensity in cd Maximum luminous intensity in cd when used as A single lamp A lamp marked “D” (see paragraph 4.2.2.3. above) 1 175 1000 500 1a 250 1200 600 1b 400 1200 600 2a (steady) 50 500 250 2b (variable) 50 1000 500 5 0.6 280 140 6 50 280 140
Intensity of light emitted. 6.1. Intensity of the light specifications for reversing lamps.
Intensity of light emitted. 6.1. The intensity of the light emitted by each of the two samples shall be not less than the minima and not greater than the maxima specified below and shall be measured in relation to the axis of reference in the directions shown below (expressed in degrees of angle with the axis of reference).
Intensity of light emitted. 6.1. The light emitted by each of the two devices supplied shall be in the reference axis, of not less than the minimum intensity and of not more than the maximum intensity specified below: Minimum luminous intensity in cd Maximum luminous intensity in cd when used as Single lamp Lamp (single) marked "D" paragraph (4.2.2.6.) Total for the assembly of two or more lamps
AutoNDA by SimpleDocs
Intensity of light emitted. In the reference axis, the intensity of the emitted light of each of the two devices shall be at least equal to the minimum values and not exceed the maximum values of the following table. In no direction, the maximum values indicated shall be exceeded. min. (cd) max. (cd) 7.1. Rear position lamp 4 12 7.2. Front position lamp 4 60
Intensity of light emitted. 7.1. The intensity of the light emitted by each of the two samples submitted shall be: Side-marker lamp category SM1 SM2 Minimum intensity In the axis of reference 4.0 cd 0.6 cd Within the specified angular field, other than above 0.6 cd 0.6 cd Maximum intensity Within the specified angular field 3/ 25.0 cd 25.0 cd Angular field Horizontal + 45 deg. + 30 deg. Vertical + 10 deg. + 10 deg.
Intensity of light emitted. 6.1. The light emitted by each of the two devices supplied must be in the case of direction indicators of categories 1, 1a, 1b, 2a, 2b, 3 or 4 in the reference axes, in the case of direction indicators of categories 5 or 6 in direction A according to Annex 1 of not less than the minimum intensity and of not more than the maximum intensity specified below: Direction indicator of category Minimum luminous intensity in cd Maximum luminous intensity in cd when used as Single lamp 3/ Lamp (single) marked "D" (see paragraph 4.2.2.3.) 3/ Total for the assembly of two lamps (see paragraph 4.2.2.3.) 3/ 1 175 700 500 1000 1a 250 800 600 1200 1b 400 860 600 1200 2a (steady) 50 350 250 500 2b (variable) 50 700 500 1000 3 to the front 175 700 500 1000 to the rear 50 200 140 280 4 to the front 175 700 500 1000 to the rear 0.6 200 140 280 5 0.6 200 140 280 6 50 200 140 280 3/ The total value of maximum intensity for an assembly of two or more lamps is given by multiplying by 1.4 the value prescribed for a single lamp, except for category 2a. When an assembly of two or more lamps having the same function is deemed to be, for the purpose of installation on a vehicle, a "single lamp", this assembly shall comply with the minimum intensity required when one lamp has failed, and, all the lamps together shall not exceed the admissible maximum intensity (last column of the table). In the case of a single lamp containing more than one light source: