Employee Facilities Employee Facilities. Restrooms and attendant facilities shall be provided as required in the orders and regulations of the State of Washington Department of Labor and Industries. A good faith effort will be made by the Employer to provide facilities for employees’ personal belongings.
Unbundled Digital Loops 2.3.1 BellSouth will offer Unbundled Digital Loops (UDL). UDLs are service specific, will be designed, will be provisioned with test points (where appropriate), and will come standard with OC and a DLR. The various UDLs are intended to support a specific digital transmission scheme or service. 2.3.2 BellSouth shall make available the following UDLs, subject to restrictions set forth herein:
Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.
Unbundled Loop Modifications (Line Conditioning 2.5.1 Line Conditioning is defined as routine network modification that BellSouth regularly undertakes to provide xDSL services to its own customers. This may include the removal of any device, from a copper Loop or copper Subloop that may diminish the capability of the Loop or Subloop to deliver high-speed switched wireline telecommunications capability, including xDSL service. Such devices include, load coils, excessive bridged taps, low pass filters, and range extenders. Excessive bridged taps are bridged taps that serves no network design purpose and that are beyond the limits set according to industry standards and/or the BellSouth’s TR 73600 Unbundled Local Loop Technical Specification. 2.5.2 BellSouth will remove load coils only on copper Loops and Subloops that are less than eighteen thousand (18,000) feet in length. 2.5.3 For any copper loop being ordered by NewPhone which has over six thousand (6,000) feet of combined bridged tap will be modified, upon request from NewPhone, so that the loop will have a maximum of six thousand (6,000) feet of bridged tap. This modification will be performed at no additional charge to NewPhone. Loop conditioning orders that require the removal of bridged tap that serves no network design purpose on a copper Loop that will result in a combined total of bridged tap between two thousand five hundred (2,500) and six thousand (6,000) feet will be performed at the rates set forth in Exhibit A. 2.5.4 NewPhone may request removal of any unnecessary and non-excessive bridged tap (bridged tap between zero (0) and two thousand five hundred (2,500) feet which serves no network design purpose), at rates pursuant to BellSouth’s SC Process as mutually agreed to by the Parties. 2.5.5 Rates for ULM are as set forth in Exhibit A. 2.5.6 BellSouth will not modify a Loop in such a way that it no longer meets the technical parameters of the original Loop type (e.g., voice grade, ADSL, etc.) being ordered. 2.5.7 If NewPhone requests ULM on a reserved facility for a new Loop order, BellSouth may perform a pair change and provision a different Loop facility in lieu of the reserved facility with ULM if feasible. The Loop provisioned will meet or exceed specifications of the requested Loop facility as modified. NewPhone will not be charged for ULM if a different Loop is provisioned. For Loops that require a DLR or its equivalent, BellSouth will provide LMU detail of the Loop provisioned. 2.5.8 NewPhone shall request Loop make up information pursuant to this Attachment prior to submitting a service inquiry and/or a LSR for the Loop type that NewPhone desires BellSouth to condition. 2.5.9 When requesting ULM for a Loop that BellSouth has previously provisioned for NewPhone, NewPhone will submit a SI to BellSouth. If a spare Loop facility that meets the Loop modification specifications requested by NewPhone is available at the location for which the ULM was requested, NewPhone will have the option to change the Loop facility to the qualifying spare facility rather than to provide ULM. In the event that BellSouth changes the Loop facility in lieu of providing ULM, NewPhone will not be charged for ULM but will only be charged the service order charges for submitting an order.
TEACHER FACILITIES A. The Board shall provide for each actively employed teacher: 1. A serviceable desk, chair and computer. 2. Access to a dining table. 3. A lockable desk, file cabinet or closet in which teachers may store instructional materials and supplies. 4. An appropriately furnished room to be reserved for the exclusive use of staff as a faculty lounge. Said room will be regularly cleaned by the custodial staff and will be in addition to the other teacher work areas. However, staff will be expected to keep the lounge reasonably neat and orderly. 5. Access to well-lighted and clean employee restrooms, separate from the students' restrooms with appropriate supplies. 6. Storage facilities for special instructional personnel. 7. In accordance with applicable food and nutrition guidelines, the principal, at request by a majority of the teachers, may arrange for the installation of a maximum of two faculty vending machines in each faculty lounge. All proceeds from the machines shall be used in such manner as the majority of teachers and educational support employees of that building shall determine. Cost, if any, of installation shall be borne by the teachers and educational support employees of each school. B. Where feasible in existing buildings, and in all new buildings, the following will be provided. 1. A teacher work area containing adequate equipment and supplies to aid in the preparation of instructional materials. 2. A communication system so that teachers can communicate with the main office from their classrooms, provided that such system is used only for emergency announcements during class periods. 3. Space for teachers' dining in a faculty lounge or other room unavailable to students with tables and chairs sufficient to accommodate teachers during their lunch period. C. Teachers shall report in writing to the principal any condition considered unsafe or hazardous. The principal shall take action(s) as appropriate and shall notify the teacher in writing of such action(s) taken within five (5) days. D. A telephone will be made available for teachers to use for school business. Teachers and principals shall arrange this use to provide reasonable privacy during the call. During the workday, teachers may make personal phone calls only if the calls cannot be made at any other time. E. Teachers who need access to a telephone for school business after the workday ends shall arrange this access with the principal. Teachers with supervisory responsibilities will also have access to the building. F. An adequate portion of the parking lots at each school will be reserved for teacher parking. Effective July 1, 2012, newly hired employees assigned to the South East Street Central Office location will be required to pay a fee of $45 per month if they elect to park in designated BOE parking areas. Twelve-month employees may elect payroll deduction to allocate payments over 24 equal paychecks. Eleven-month employees may elect payroll deduction to allocate payments over 22 equal paychecks. Ten-month employees may elect payroll deduction to allocate payment over 20 equal paychecks. G. The Board will take steps to ensure teachers have access to their classrooms when custodians unlock the buildings in the morning and up to one (1) hour before custodial shifts end on weekdays during the school year, provided rooms are not being utilized by outside user groups. Teachers shall have access to their rooms during summer operating hours during summer months unless there is scheduled maintenance, outside user groups or FCPS programs occurring.
Unbundled Network Element Combinations 5.1. Unbundled Network Element Combinations shall include: 1) Enhanced Extended Links (EELs); 2) UNE Loops/Special Access Combinations; 3) Loop/Port Combinations; and 4)
Wire Unbundled DS1 Digital Loop This is a designed 4-wire Loop that is provisioned according to industry standards for DS1 or Primary Rate ISDN services and will come standard with a test point, OC, and a DLR. A DS1 Loop may be provisioned over a variety of loop transmission technologies including copper, HDSL-based technology or fiber optic transport systems. It will include a 4-Wire DS1 Network Interface at the End User’s location.
Porcupine Site Highway 11 and the City of Timmins Thunder Bay and District Toronto/York-Peel
Unbundled Loops 2.1.1 BellSouth agrees to offer access to unbundled loops pursuant to the following terms and conditions and at the rates set forth in Attachment 11.
Unbundled Network Elements 35.4.1. The charges that CLEC shall pay to Sprint for Unbundled Network Elements are set forth in Table One of this Agreement. 35.5. Collocation 35.5.1. The charges that CLEC shall pay to Sprint for Collocation are set forth in Table Two of this Agreement. 35.6. Call Related Databases 6.1. The charges that CLEC shall pay to Sprint for Call Related Databases purchased pursuant to Part J are set forth in Table One of this Agreement.