LIGHTING FIXTURES Sample Clauses

LIGHTING FIXTURES. 4.1 Office and Lab area light fixtures shall be min. 6" wide recessed linear LED type by Finelite or equivalent. 4.2 Lab Support rooms shall have recessed 2'x4' LED troffers. 4.3 All lighting shall have Title 24 compliant lighting controls and sensors.
AutoNDA by SimpleDocs
LIGHTING FIXTURES. 14.4.1 Lessor shall furnish and install complete lighting system, including fixtures, lamps and all required wiring and switches. Fixtures shall be of the type indicated on drawing furnished by Lessee. Lighting fixture installation shall be coordinated with sprinkler system to permit sprinkler system to be installed in compliance with NFPA #13. Provide tube guards as required by Health Department. 14.4.2 Fluorescent fixture ballasts shall be CBM certified, ETL rated, Class P, high power factor. Sound level shall be not greater than General Electric sound rating "A". 14.4.3 The fluorescent fixtures in the general sales area shall be 2-tube 96" long on 8'-0" centers as noted on plans. Fixtures will be mounted 15'-0" A.F.F. Use Metalux SS 296, or equal, with F96Tl2/SP35/WM lamps. 14.4.4 All fixtures' lenses shall be glass or acrylic.
LIGHTING FIXTURES. 4.1 Light Levels in the building are specified at 3,500 Xxxxx. 4.2 Lab area light fixtures shall be: recessed 4” wide linear LED type by Nulite Lighting, Regolo 4 LED RG4. 4.3 Office areas shall utilize the lab area light fixtures and also employ 9” round X 18” tall Pendants by Xxxxxx Lighting (LSR8A) 4.4 Lab Support rooms shall have recessed 2’x4’ LED fixtures. 4.5 All lighting shall have Title 24 compliant lighting controls and sensors.
LIGHTING FIXTURES. Replacement of light tubes or bulbs for Building standard lighting fixtures. Al light tube or bulb replacements for special nonstandard lighting fixtures shall be furnished and installed at Tenant’s expense.
LIGHTING FIXTURES. See Item# 16 below. Landlord will ensure all lamps are in good working order.
LIGHTING FIXTURES. Standard fixtures shall be 2'x4' lighting fixtures with 4-40 watt fluorescent lamps to provide a minimum of 60 foot candles. Fixtures shall be with E type, energy saving ballast and provide plenum air return function. Emergency egress lighting shall be provided by the use of standard fixtures with emergency battery back-up power, as required by code.
LIGHTING FIXTURES. Landlord will supply and install 2’ x 4’ parabolic fluorescent lighting fixtures in the amount of one fixture for every 85 square feet of ceiling area. Lamps will be furnished and installed by Landlord.
AutoNDA by SimpleDocs
LIGHTING FIXTURES. A. LED fixtures in the garage, stairs, and vehicle entries/exists B. Lighting levels provided to meet recommended minimums per IES “Lighting for Parking Facilities” (IES RP-20-14): i. Parking levels: 5 foot-candles (FCs) average (in parking lanes), 1 FC minimum ii. Elevator lobby: 25-30 FC iii. Stairways: 10 FCs minimum C. Motion and daylight controls
LIGHTING FIXTURES. A. Peerless — Peerlite — Xxxxx 7 suspended light fixtures with two (2), 28 watt T5 lamps. Fixtures at perimeter building wall spaces (alignment and direction) to be approved by Landlord. Lighting fixtures to meet title 24 requirements or 2’ x 4’/2’ x 2’ fixtures reasonably acceptable to Landlord.
LIGHTING FIXTURES. All existing lighting and plumbing fixtures or heat, ventilation and air conditioning system now contained or thereafter installed in the Demised Premises are or shall be deemed the property of the Landlord and shall be maintained and repaired and/or replaced by Tenant as and when necessary. At the end of the term, Tenant shall not remove any such fixtures, whether original or replaced by Tenant or installed by Tenant in the Demised Premises.