Measurement System Sample Clauses

Measurement System. Customer shall not alter, move, modify or otherwise change the measurement and verification system or any component thereof without the prior written
AutoNDA by SimpleDocs
Measurement System. Customer shall not alter, move, modify or otherwise change the measurement and verification system or any component thereof without the prior written consent of Ameresco unless such action is in accordance with operating procedures provided by Ameresco.
Measurement System. Fully automated data acquisition and test control system. Load, displacement, and temperature are simultaneously recorded every 0.1 sec.
Measurement System. Analysis (MSA)
Measurement System. The measurement system shall be designed with sufficient redundancy (3x50 %) such that the failure of a single meter run does not shut down the whole measurement system. Each of these meter runs shall incorporate a single turbine meter and a single multipath ultrasonic meter in series in full compliance with above listed standards. Double block and bleed valves shall be provided upstream and downstream of each meter run to allow switching from one run to another without compromising measurement performance and to ensure no gas bypasses the intended meter runs.
Measurement System. The Quality Manual will define the Measurement System to be used to obtain the data necessary to verify that DMOQs have been met, and to provide data needed to perform source cause and root cause analyses. Changes to the agreed upon Measurement System must be reviewed with and concurred by AT&T prior to their implementation, GTE will review metrics on a monthly basis with AT&T and will be available for review and analysis, as mutually agreed to be necessary, for all services. Measures shall be AT&T specific and support AT&T service performance requirements.
Measurement System. 1 This section specifies the measurement rules that will generally be used for payment purposes unless otherwise specified in the Contract Documents. In case of conflict between the method of measurement specified in this section and the requirements specified in Section 01 28 00 – Measurement Schedule, the latter will govern.
AutoNDA by SimpleDocs
Measurement System. GR&R must be done for all the measurement systems and updated timely, the acceptable criterial follows industry standard (P/T Ratio<30%). Any deviation will be subjected to Cognex approval. Calibration must be done per national standard in timely manner.
Measurement System. Set of equipment required for the measurement of electric grandeur, such as set of measurers, power transformers, current transformers and associated equipment, as required to measure active and reactive energy, active and reactive power, tension, etc., according to the Technical Specifications of the Measurement System for the invoicing of Electric Power of ONS/CCEE;
Measurement System. 10.1 The MEASUREMENT SYSTEM will be installed in the CONNECTION POINTS established under ENCLOSURE I of the CCD. 10.2 The installation and maintenance of the equipment of the MEASUREMENT SYSTEM destined to measure the electrical grandeurs required to determine the USAGE CHARGES lie under the responsibility of the GENERATOR. 10.3 The GENERATOR will be responsible for the adjustment of the MEASUREMENT SYSTEM to meet the specifications established by ONS/CCFE, as defined by XXXXX Resolution no. 344 dated 06/25/2002 or any other which may come to supersede it. 10.4 The PARTIES hereby shall comply with the DISTRIBUTION PROCEDURES, the SALE PROCEDURES, and the NETWORK PROCEDURES regarding the responsibility for the installation, maintenance and reading of the MEASUREMENT SYSTEM. 10.5 The PARTIES hereby assure the mutual access to the CONNECTION FACILITIES and/or CONNECTION POINT, including the measurement equipment. 10.6 The GENERATOR shall be responsible for the safeguard of the MEASUREMENT SYSTEM, including the corresponding seal, and shall not intervene nor allow third parties to intervene in its operation without the presence of duly qualified representatives of the DISTRIBUTOR. 10.7 Each of the PARTIES shall be liable for its corresponding obligations before the CCEE. 10.8 The DISTRIBUTOR will be responsible for the following measurement procedures in the SCL: collection, remittance and adjustment of measurement data. The GENERATOR is responsible for the penalties resulting from non compliance with its obligations related to the measurement before SCL. 10.9 The modeling of the PLANT at CCEE shall determine values of power injected to the DISTRIBUTION SYSTEM, applying to this situation the invoicing provided under item 5.4 of ARTICLE 5.