Pigging Facilities and Mainline Block Valves. 3.1. Flanges and any existing launchers for pigging are included. 3.2. Above ground mainline block valves are included as shown on the route map. 3.2.1. Mainline block valves are flanged end, double block and bleed, expanding gate valves. Each valve setting is equipped with bypass assemblies and security fencing. 3.2.2. Manually operated valves are equipped with gear operators. 3.2.3. Automated valves are equipped with electric motor operators for local or remote operation. SCADA equipment includes a PLC/RTU suitable for mounting on an outdoor rack and a pipe pedestal-mounted VSAT.
Appears in 2 contracts
Samples: Purchase and Sale Agreement, Purchase and Sale Agreement (Shell Midstream Partners, L.P.)
Pigging Facilities and Mainline Block Valves. 3.1. 3.1 Flanges and any existing launchers for pigging are included.
3.2. 3.2 Above ground mainline block valves are included as shown on the route map.
3.2.1. 3.2.1 Mainline block valves are flanged end, double block and bleed, expanding gate valves. Each valve setting is equipped with bypass assemblies and security fencing.
3.2.2. 3.2.2 Manually operated valves are equipped with gear operators.
3.2.3. 3.2.3 Automated valves are equipped with electric motor operators for local or remote operation. SCADA equipment includes a PLC/RTU suitable for mounting on an outdoor rack and a pipe pedestal-mounted VSAT.
Appears in 1 contract
Samples: Purchase and Sale Agreement (Shell Midstream Partners, L.P.)
Pigging Facilities and Mainline Block Valves. 3.1. 3.1 Flanges and any existing launchers for pigging are included.
3.2. 3.2 Above ground mainline block valves are included as shown on the route map.
3.2.1. 3.2.1 Mainline block valves are flanged end, double block and bleed, expanding gate valves. Each valve setting is equipped with bypass assemblies and security fencing.
3.2.2. 3.2.2 Manually operated valves are equipped with gear operators.
3.2.3. 3.2.3 Automated valves are equipped with electric motor operators for local or remote operation. SCADA equipment includes a PLC/RTU suitable for mounting on an outdoor rack and a pipe pedestal-mounted VSAT.. Exhibit D-3
Appears in 1 contract
Samples: Purchase and Sale Agreement