Interconnection 2.2.10 Startup Testing and Commissioning
Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.
Maintenance and Repair (a) Except for any Alterations that Tenant is permitted to make pursuant to this Lease, Tenant shall at all times put, keep and maintain the Leased Premises (including, without limitation, the roof, landscaping, walls, footings, foundations and structural components of the Leased Premises) in the same (or better) condition and order of repair as exists as of the Commencement Date, except for ordinary wear and tear, and shall promptly make all repairs and replacements of every kind and nature, whether foreseen or unforeseen, which may be required to be made upon or in connection with the Leased Premises in order to keep and maintain the Leased Premises in the order and condition required by this Paragraph 11(a). Tenant shall do or cause others to do all shoring of the Leased Premises or of foundations and walls of the Improvements and every other act necessary or appropriate for preservation and safety thereof, by reason of or in connection with any excavation or other building operation upon any of the Leased Premises, whether or not Landlord shall, by reason of any Legal Requirements or Insurance Requirements, be required to take such action or be liable for failure to do so. LANDLORD SHALL NOT BE REQUIRED TO MAKE ANY REPAIR, WHETHER FORESEEN OR UNFORESEEN, OR TO MAINTAIN ANY OF THE LEASED PREMISES IN ANY WAY, AND TENANT HEREBY EXPRESSLY WAIVES THE RIGHT TO MAKE REPAIRS AT THE EXPENSE OF THE LANDLORD, WHICH RIGHT MAY BE PROVIDED FOR IN ANY LAW NOW OR HEREAFTER IN EFFECT. Nothing in the preceding sentence shall be deemed to preclude Tenant from being entitled to insurance proceeds or condemnation awards for Restoration pursuant to Paragraphs 13(c) and 14(g). Tenant shall, in all events, make all repairs for which it is responsible hereunder promptly (but in any event shall commence actions to initiate such repairs as quickly as possible after the date Tenant becomes aware that such repairs are necessary, or, in the event of a Restoration pursuant to Paragraph 13(c) or 14(g), within sixty (60) days of the date insurance proceeds or a condemnation award has been paid to the Trustee (it being understood that Tenant shall take such steps as are reasonably necessary to protect and preserve the integrity and safety of the Leased Premises pending such payment) and shall diligently pursue such repairs to completion), and all repairs shall be made in a good, proper and workmanlike manner.
Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.