Proper Design Sample Clauses

Proper Design. The County’s review of any design documents shall not relieve Wastewater Thermal Energy User from its obligation to properly design the Connection and Project and to obtain all necessary permits and approvals for the Connection and Project.
AutoNDA by SimpleDocs

Related to Proper Design

  • Timber Designations Timber designated for cutting shall be confined to Sale Area, except as provided in B2.131, B2.14, B2.15, B2.32, and B5. 1. Sale Area Map

  • Board Composition and Board Designations The Company shall ensure that: (i) the qualifications of the persons serving as members of the Board of Directors and the overall composition of the Board comply with the Sxxxxxxx-Xxxxx Act, with the Exchange Act and with the listing rules of the Exchange or any other national securities exchange, as the case may be, in the event the Company seeks to have its Public Securities listed on another exchange or quoted on an automated quotation system, and (ii) if applicable, at least one member of the Audit Committee of the Board of Directors qualifies as an “audit committee financial expert,” as such term is defined under Regulation S-K and the listing rules of the Exchange.

  • Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety

  • Failure to Designate a Board Member In the absence of any designation from the Persons or groups with the right to designate a director as specified above, the director previously designated by them and then serving shall be reelected if still eligible to serve as provided herein.

  • Membership Meetings At the request of the Union the University agrees to grant a two (2) hour period twice a calendar year for purposes of a regular membership meeting. The University agrees to grant time off from work without loss of pay to those Employees regularly scheduled to work during that time.

  • Project Director The individual designated by the juvenile board or Chief Administrative Officer, who is to be responsible for the administration and coordination of grant funds in accordance with this Contract ,, the general grant requirements, and applicable Targeted Grant requirements.

  • Project Steering Committee 1. For a sound implementation and management of the project, a steering committee shall be set up in line with provisions of the programme manual. 2. The steering committee is the decision-making body of the project and it shall be composed by representatives of the LP and all PPs duly authorised to represent the respective LP and PP institutions. It shall be chaired by the LP and it shall meet on a regular basis. Associated partners shall be invited to take part in the steering committee in an advisory capacity. External key stakeholders may also be invited to take part to one or more meetings in an observer/advisory capacity. 3. The steering committee shall at least: a. be responsible for monitoring and validating the implementation of the project and the achievement of the planned results as in the approved application form; b. perform the financial monitoring of the project implementation and to decide on any budget modifications as in § 11 of this agreement; c. monitor and manage deviations of the project implementation; d. decide on project modifications (e.g. partnership, budget, activities, and duration) if needed; e. be responsible for the settlement of any disputes within the partnership (as stipulated in § 22 of this agreement). 4. Further aspects, including the creation of sub-groups or task forces, may be set out in the rules of procedure of the steering committee.

  • Development Committee Arcadia and Xxxxxx shall establish a development committee (the “Development Committee”) comprised of no more than three (3) representatives of each of Arcadia and Xxxxxx. The Development Committee shall be chaired by a member thereof designated from time to time by Arcadia. The Development Committee shall oversee the Research Plan, Milestones and development and production of plants and microorganisms that produce Transgenic Oil in accordance with the Research Plan. The Development Committee may revise the Research Plan and the Milestones as deemed necessary and appropriate by unanimous written consent of all members. Meetings of the Development Committee shall be at least biannual and at such times and places or in such form (e.g., in person, telephonic or video conference) as the members of the Development Committee shall determine. Representatives of both Parties shall be present at any meeting of the Development Committee. Decisions of the Development Committee shall be made by a written consent signed by all six (6) members thereof. The Development Committee shall keep minutes of its deliberations setting forth, among other matters, all proposed actions and all votes thereon. All records of the Development Committee shall at all times be available to both Parties. The Development Committee by unanimous consent may delegate to one Party or to a specific representative the authority to make certain decisions. The Development Committee may revoke such authority by the written consent of four members. All disagreements within the Development Committee shall be subject to the following: (i) The members of the committee will endeavor in good faith for a period of not more than ninety (90) days to attempt to resolve the disagreement; (ii) If the members of the committee are unable to resolve the disagreement by the end of such period, the committee shall promptly present the disagreement to the President of Xxxx Products Division and the President of Arcadia or their respective designees, and the two executives shall endeavor to resolve the disagreement for a period of not more than thirty (30) days; (iii) If the two executives are unable to resolve this disagreement, the disagreement shall be submitted for ADR as provided in Section 12(a).

  • Observers Each Sponsor and MCK shall have the right, exercisable by delivering notice to the Company, to designate one (1) non-voting observer to attend any meetings of the Board of Directors, the boards of directors and equivalent governing bodies of Echo’s Subsidiaries and any committees of either of the foregoing. Notice of meetings of the Board of Directors, the boards of directors and equivalent governing bodies of Echo’s Subsidiaries and any committees thereof shall be furnished (together with all materials to be provided to the Board of Directors) to each non-voting observer no later than, and using the same form of communication as, notice of meetings of the Board of Directors, the Board of Managers, the boards of directors and equivalent governing bodies of Echo’s Subsidiaries and any committees thereof, as the case may be, that are furnished to the members of the Board of Directors, the Board of Managers, the boards of directors and equivalent governing bodies of Echo’s Subsidiaries and any committees thereof, respectively; provided, that Echo, the Company or its Subsidiaries, as the case may be, shall be entitled to remove such observer from such portions of a meeting of the Board of Directors, the Board of Managers, the boards of directors or equivalent governing bodies of any of Echo’s Subsidiaries or any committees thereof, in each case, to the extent such observer’s presence would be likely to result in the waiver of any attorney client privilege. Any observer designated under this Section 3.1(h) shall be permitted to attend any meeting of any of the Board of Directors, the boards of directors and equivalent governing bodies of Echo’s Subsidiaries and any committees of either of the foregoing, in each case, using the same form of communication permitted for members of such Board of Directors, boards of directors and equivalent governing bodies of Echo’s Subsidiaries or any committees thereof.

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!