Remote Control. Located at the switchyard control room, where switching devices are controlled by direct wire .
Remote Control. I shall not use any remote control software or service on any internal or external host or systems not specifically approved by agency management, IOT support, and the CISO.
Remote Control. 13.3.1. If a remote control device, as defined in paragraph 2.8. of this Regulation, is employed, there shall also be a remote indication device as described in paragraph 13.2.
13.3.2. There shall be a dedicated switch (i.e. master switch, lever or valve) to enable the coupling to be opened or closed by means of the remote control device. If this master switch is not located in the driving cab it shall not be in a position where it is freely accessible to unauthorised persons or it shall be lockable. The actual operation of the coupling from the driving cab may only be possible when inadvertent operation has been precluded, for example by an operation requiring the use of two hands. It shall be possible to ascertain whether opening of the coupling under remote control has been completed or not.
13.3.3. If remote control involves the coupling being opened by external force, the condition under which the external force acts on the coupling shall be indicated appropriately to the driver. This is not necessary if the external force is only operative while the remote control is operating.
13.3.4. If the actuating device for opening the coupling under remote control is mounted externally on the vehicle it shall be possible to oversee the area between the coupled vehicles, but it shall not be necessary, however, to enter this area in order to operate it.
13.3.5. Any single error in operation or the occurrence of any single fault in the system shall not result in accidental opening of the coupling during normal road use. Any faults in the system shall be indicated directly or be immediately obvious at the next operation e.g. by a malfunction.
13.3.6. In the event of a failure of the remote control it shall be possible, in an emergency, to open the coupling in at least one other way. If this requires the use of a tool then this shall be included in vehicle's tool kit. The requirements of paragraph 3.6. of this annex are not applicable to hand levers used exclusively for opening the coupling in an emergency.
13.3.7. The remote control devices shall be permanently and clearly identified.
1. General testing requirements
1.1. Samples of coupling devices shall be tested for both strength and function. Physical testing shall be carried out wherever possible but unless stated otherwise the Type Approval Authority or Technical Service may waive a physical strength test if the simple design of a component makes a theoretical check possible. Theoretical checks may be carried...
Remote Control. We provide remote control software (currently "Go To Assist") at our own expense for the purposes of troubleshooting, file transfer, and problem resolution. Please do not attempt to connect via remote control unless we have instructed you to do so. We are not obligated to accept unsolicited remote control connections.
Remote Control. 12.3.1. If a remote control device, as defined in paragraph 2.8. of this Regulation, is employed, there shall also be a remote indication device as described in paragraph 12.2. which shall at least indicate the open condition of the coupling.
12.3.2. There shall be a dedicated switch (i.e. master switch, lever or valve) to enable the coupling to be opened or closed by means of the remote control device. If this master switch is not located in the driving cab it shall not be in a position where it is freely accessible to unauthorised persons or it shall be lockable. The actual operation of the coupling from the driving cab may only be possible when inadvertent operation has been precluded, for example by an operation requiring the use of two hands. It shall be possible to ascertain whether opening of the coupling under remote control has been completed or not.
12.3.3. If remote control involves the coupling being opened by external force, the condition under which the external force acts on the coupling shall be indicated appropriately to the driver. This is not necessary if the external force is only operative while the remote control is operating.
Remote Control. The wheelchair lift shall be equipped with a corded remote control so the operator can operate the lift from inside the bus, standing on the lift, or standing on the ground beside the lift.
Remote Control. Clear Up/Down Enter Exit Menu
Remote Control. To be able to implement and provide the Products and Services correctly, it may be required that you provide ForeNova’s technical team with remote access to Collectors based on your configuration in the integration settings of the Collectors, and to provide them the relevant authority such as, command issuing for fixing related risk issues.
Remote Control. 13.3.1. If a remote control device, as defined in paragraph 2.8. of this Regulation, is employed, there shall also be a remote indication device as described in paragraph 13.2.
13.3.2. There shall be a dedicated switch (i.e. master switch, lever or valve) to enable the coupling to be opened or closed by means of the remote control device. If this master switch is not located in the driving cab it shall not be in a position where it is freely accessible to unauthorised persons or it shall be lockable. The actual operation of the coupling from the driving cab may only be possible when inadvertent operation has been precluded, for example by an operation requiring the use of two hands. It shall be possible to ascertain whether opening of the coupling under remote control has been completed or not.
13.3.3. If remote control involves the coupling being opened by external force, the condition under which the external force acts on the coupling shall be indicated appropriately to the driver. This is not necessary if the external force is only operative while the remote control is operating.
13.3.4. If the actuating device for opening the coupling under remote control is mounted externally on the vehicle it shall be possible to oversee the area between the coupled vehicles, but it shall not be necessary, however, to enter this area in order to operate it.
Remote Control. We will allow you to try out the remote control features on evaluation but this service will incur an additional cost in order to use a standalone blue spider workstation for the purpose of connecting to the remote system(s) as a client.