Scope of Interconnection Service Sample Clauses

Scope of Interconnection Service. 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.
AutoNDA by SimpleDocs
Scope of Interconnection Service. 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection, subject to the requirements in Attachment 5. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.
Scope of Interconnection Service. 1.3.1 NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection, with Capacity Resource Interconnection Service subject to the provisions set forth in Attachment 5. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the NYISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.
Scope of Interconnection Service. 4.1 Provision of Service. NYISO will provide Developer with interconnection service of the following type for the term of this Agreement.
Scope of Interconnection Service. 1.3.1 The NYISO will provide Energy Resource Interconnection Service to NYPA at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver power. The purchase or delivery of power and other services that NYPA may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s tariffs. NYPA will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff. If NYPA wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then NYPA will make application to do so in accordance with the NYISO Services Tariff.
Scope of Interconnection Service. 4.1 Provision of Service.
AutoNDA by SimpleDocs
Scope of Interconnection Service. 1.3.1 NYISO will provide Capacity Resource Interconnection Service and Energy Resource Interconnection Service to RG&E at the Point of Interconnection, with Capacity Resource Interconnection Service subject to the provisions set forth in Attachment 5. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver power. The purchase or delivery of power and other services that RG&E may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s tariffs. RG&E will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the NYISO OATT. The execution of this Agreement does not constitute a request for, nor agreement to, provide energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff. If RG&E wishes to supply or purchase energy, Installed Capacity or Ancillary Services, then RG&E will make application to do so in accordance with the NYISO Services Tariff.
Scope of Interconnection Service. 4.1 Provision of Service. Developer will receive interconnection service of the following types for the term of this Agreement, as determined by the NYISO, pursuant to the NYISO Tariff. Product. Pursuant to the NYISO OATT, Developer will receive Energy Resource Interconnection Service and Capacity Resource Interconnection Service at the Point of Interconnection, as determined by the NYISO, pursuant to the NYISO Tariff. Developer Developer is responsible for ensuring that its actual Large Generating Facility output matches the scheduled delivery from the Large Generating Facility to the New York State Transmission System, consistent with the scheduling requirements of the NYISO’s FERCapproved market structure, including ramping into and out of such scheduled delivery, as measured at the Point of Interconnection, consistent with the scheduling requirements of the NYISO OATT and any applicable FERC-approved market structure.
Scope of Interconnection Service. 3.2.1 Interconnection Service shall consist of the services necessary to allow the physical interconnection of the Facility pursuant to the terms of this Agreement. Interconnection Service does not mean and shall not include transmission service, ancillary services, losses, or any other service available under the EPE OATT. -------------------------------------------------------------------------------- Interconnection Agreement between -9- EXECUTION VERSION El Paso Electric Company and Public Service Company of New Mexico Specifically, Interconnection Service shall not include the purchase or sale of energy or ancillary services to or from the Facility beyond the Interconnection Point, or the delivery of energy or ancillary services from the Facility beyond the Interconnection Point, which services shall be provided separately under the EPE OATT or by others under separate agreements, as applicable. 3.2.2 Generator shall be responsible for (a) making arrangements under the EPE OATT for transmission and ancillary services on the EPE Transmission System, and under other applicable tariffs for such services on other transmission system(s), associated with the injection or delivery of the capacity and/or energy produced by the Facility beyond the Interconnection Point, which services shall not be provided under the terms of this Agreement, (b) obtaining capacity and/or energy to satisfy its Facility service or other requirements, and (c) making arrangements under applicable tariffs for transmission services, losses, and ancillary services associated with the use of the EPE Transmission System for the injection or delivery of capacity and/or energy to other generating facilities owned by Generator for the purpose of supplying facility service or for any other use. EPE makes no representations to Generator regarding the availability of transmission service on the EPE Transmission System, and Generator agrees that the availability of such transmission service may not be inferred or implied from this Agreement. Generator must request such transmission service in accordance with the EPE OATT. 3.2.3 In the event of an increase in the output of the Facility or other material change or modification to the configuration and/or operation of the Facility, the Parties shall negotiate appropriate revisions to this Agreement, including, as necessary, the performance by EPE of studies to determine the effects of such increase or change, and changes to the specifications or ...
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!