Asset Representations Review Process Section 3.01 Asset Representations Review Notices and Identification of Review Receivables. On receipt of an Asset Representations Review Notice from the Seller according to Section 5.7 of the Receivables Purchase Agreement, the Asset Representations Reviewer will start an Asset Representations Review. The Servicer will provide the list of Review Receivables to the Asset Representations Reviewer promptly upon receipt of the Asset Representations Review Notice. The Asset Representations Reviewer will not be obligated to start, and will not start, an Asset Representations Review until an Asset Representations Review Notice and the related list of Review Receivables is received. The Asset Representations Reviewer is not obligated to verify (i) whether the conditions to the initiation of the Asset Representations Review and the issuance of an Asset Representations Review Notice described in Section 7.6 of the Indenture were satisfied or (ii) the accuracy or completeness of the list of Review Receivables provided by the Servicer.
Project Review A. Programmatic Allowances 1. If FEMA determines that the entire scope of an Undertaking conforms to one or more allowances in Appendix B of this Agreement, with determinations for Tier II Allowances being made by SOI-qualified staff, FEMA shall complete the Section 106 review process by documenting this determination in the project file, without SHPO review or notification. 2. If the Undertaking involves a National Historic Landmark (NHL), FEMA shall notify the SHPO, participating Tribe(s), and the NPS NHL Program Manager of the NPS Midwest Regional Office that the Undertaking conforms to one or more allowances. FEMA shall provide information about the proposed scope of work for the Undertaking and the allowance(s) enabling FEMA’s determination. 3. If FEMA determines any portion of an Undertaking’s scope of work does not conform to one or more allowances listed in Appendix B, FEMA shall conduct expedited or standard Section 106 review, as appropriate, for the entire Undertaking in accordance with Stipulation II.B, Expedited Review for Emergency Undertakings, or Stipulation II.C, Standard Project Review. 4. Allowances may be revised and new allowances may be added to this Agreement in accordance with Stipulation IV.A.3, Amendments. B. Expedited Review for Emergency Undertakings
Asset Representations Review (a) Upon the occurrence of a Delinquency Trigger with respect to any Collection Period, the Servicer will promptly send to TMCC, the Administrator, the Indenture Trustee and each Noteholder (and to each applicable Clearing Agency for distribution to Note Owners in accordance with the rules of such Clearing Agency) a notice describing (i) the occurrence of the Delinquency Trigger, and including reasonably detailed calculations thereof, and (ii) the rights of the Noteholders and Note Owners regarding an Asset Representations Review (including a description of the method by which Noteholders and Note Owners may contact the Indenture Trustee in order to request a Noteholder vote in respect of an Asset Representations Review). (b) If the Indenture Trustee notifies the Servicer pursuant to Section 12.02 of the Indenture that sufficient Noteholders have voted within the required time to initiate an Asset Representations Review of all ARR Receivables by the Asset Representations Reviewer pursuant to the Asset Representations Review Agreement, then the Servicer shall: (i) promptly notify the Asset Representations Reviewer and the Indenture Trustee of the number of ARR Receivables; (ii) within sixty (60) days after receipt by the Servicer of such notice from the Indenture Trustee, render reasonable assistance, including granting access to copies of any underlying documents and Receivable Files and all other relevant documents, to the Asset Representations Reviewer to facilitate the performance of a review of all ARR Receivables, pursuant to Section 3.2(a) of the Asset Representations Review Agreement, in order to verify compliance with the representations and warranties made to the Issuer by the Seller and the Servicer; and (iii) provide such other reasonable assistance to the Asset Representations Reviewer as it requests in order to facilitate its Asset Representations Review of the ARR Receivables pursuant to the Asset Representations Review Agreement. The Servicer may redact any materials provided to the Asset Representations Reviewer in order to remove any personally identifiable customer information. Except for the measure described in the immediately preceding sentence, the Servicer will use commercially reasonable efforts not to change the meaning of such materials or their usefulness to the Asset Representations Reviewer in connection with its review pursuant to Section 3.2(a) of the Asset Representations Review Agreement.
ADB’s Review of Procurement Decisions 11. All contracts procured under international competitive bidding procedures and contracts for consulting services shall be subject to prior review by ADB, unless otherwise agreed between the Borrower and ADB and set forth in the Procurement Plan.
Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.
ADDITIONAL SPECIAL CONTRACT CONDITIONS Special Contract Conditions revisions: the corresponding subsections of the Special Contract Conditions referenced below are replaced in their entirety with the following:
Acceptance Tests 11.1 If the Contract provides acceptance tests for Goods and/or the result of Services after their completion and/or delivery to the Purchaser, the acceptance shall only be considered as definitive when such tests have demonstrated the compliance of the Goods and/or the result of the Services to the requirements in the Contract. 11.2 Where the Contract provides for an acceptance procedure in the presence of both parties, at the successful completion of such procedure, the Purchaser shall issue the Supplier with an acceptance certificate which shall authorise the Supplier to invoice the Purchaser for any payment due on such acceptance. 11.3 The Purchaser shall at its discretion be entitled to issue and acceptancecertificate with reserves. The Supplier shall be obliged to remedy any non-conformities within the period set out in the acceptance certificate. Any payment which would otherwise have been due on acceptance may be withheld by the Purchaser in whole or part until the non- conformities underlying the reserves have been remedied.
Utilization Review NOTE: The Utilization Review process does not apply to Services that are not covered by Blue Shield because of a coverage determination made by Medicare. State law requires that health plans disclose to Subscribers and health plan providers the process used to authorize or deny health care services un- der the plan. Blue Shield has completed documen- tation of this process ("Utilization Review"), as required under Section 1363.5 of the California Health and Safety Code. To request a copy of the document describing this Utilization Review pro- cess, call the Customer Service Department at the telephone number indicated on your Identification Card.
OIG INSPECTION, AUDIT, AND REVIEW RIGHTS In addition to any other rights OIG may have by statute, regulation, or contract, OIG or its duly authorized representative(s) may conduct interviews, examine or request copies of Xxxxxx’x books, records, and other documents and supporting materials and/or conduct on-site reviews of any of Xxxxxx’x locations for the purpose of verifying and evaluating: (a) Xxxxxx’x compliance with the terms of this IA and (b) Xxxxxx’x compliance with the requirements of the Federal health care programs. The documentation described above shall be made available by Xxxxxx to OIG or its duly authorized representative(s) at all reasonable times for inspection, audit, and/or reproduction. Furthermore, for purposes of this provision, OIG or its duly authorized representative(s) may interview Xxxxxx and any of Xxxxxx’x employees or contractors who consent to be interviewed at the individual’s place of business during normal business hours or at such other place and time as may be mutually agreed upon between the individual and OIG. Xxxxxx shall assist OIG or its duly authorized representative(s) in contacting and arranging interviews with such individuals upon OIG’s request. Xxxxxx’x employees and contractors may elect to be interviewed with or without a representative of Xxxxxx present.
Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.