Title Description. Aggregation Adding together the value of separate contracts for the same supply, service or works. Contract A Contract for the purposes of these Rules shall be any agreement (whether in writing) between the grant applicant and one or more other parties for: - the sale of goods or materials. the supply of goods or materials. the execution of works the provision of services (including accommodation and facilities). Competitive Source an independent provider bidding against another independent provider Goods are material items i.e. equipment, food, vehicles etc Public Contracts Regulations 2015 are rules and regulations that Public Sector organisations must adhere to when procuring Goods, Works and Services over a certain value threshold whereby an official Tender Exercise in accordance with the Public Contracts Regulations 2015 should be undertaken. Evaluation a method of determining which offer provides the best value for money in accordance with the pre-determined evaluation criteria Evaluation Criteria A list of key requirements taken from the specification that will enable suppliers to explain how they intend to deliver the requirement which will be evaluated. The criteria by which the most economically advantageous tender will be determined is based on a combination of price/cost and quality criteria. Evaluation Panel It is best practice to establish an evaluation panel to undertake the evaluation exercise. It may be appropriate to have a cross functional team as a panel. Panel should agree specification and evaluation criteria. Panel should be consistent throughout each stage of procurement exercise Sell2Wales is a National Procurement Website where all public sector contracts are advertised. Third Party Grant Recipients can also advertise via the website free of charge, please visit the Sell2Wales website ▇▇▇▇▇://▇▇▇.▇▇▇▇▇▇▇▇▇▇.▇▇▇.▇▇▇▇▇ and contact the website helpline on 0800 222 9004 for further information. Services tasks undertaken by people i.e. consultancy services, translation services etc Specification this is a written statement that defines the requirements. The specification will vary according to the work, product or service concerned. For a simple product the specification may be a brief description, while in the case of a complex requirement it will be a comprehensive document. The description of the goods, works or services required must not refer to a specific make, brand, or source. Tender/Quote is the document compiled by a potentia...
Title Description. Each Party shall pay all taxes, fees and dues required by it because of this agreement and the services performed hereunder. Each party undertakes to indemnify and hold harmless the other party for any liability it may incur due to the other party not having fulfilled its obligation pursuant to the preceding sentence. ▇▇▇▇▇ undertakes to indemnify and hold harmless Crown for any taxes, fees, and dues levied on the Fee.
Title Description. General Specifications: Each liner shall be hardness checked. Applicability All Eskom stations with horizontal tube ▇▇▇▇▇. Tube mill liners include the drum shell liners and drum end/head liners. Identification The following identification shall be cast onto the non-working face of each liner: -Material cast identification -Supplier identification -Material grade -Casting pattern number Technical specifications: LINER:MILL,50 MM THK,SULPHURE S 0.05%
Title Description. Leak of cryogenic fluid In this scenario, either helium from the helium system or nitrogen from a liquid nitrogen insulation system leaks into the insulating vacuum space. This causes pressure increase in both the vacuum and the cryogenic fluid systems.
Title Description. 1 The Parties This Management for Hire Agreement has been entered into between ▇▇▇▇▇ Consulting AS (registration number 917 201 331) and Crown LNG AS (registration number 923 696 962). 2 The Engagement Crown LNG AS (Crown) will engage ▇▇▇▇▇▇ ▇▇▇▇▇▇▇ (GKn), owner of ▇▇▇▇▇ Consulting AS (▇▇▇▇▇), as the Managing Director (MD) of the Crown. The MD reports to the Chairman of Crown. The Job Description is included in Appendix 1. The position will require full-time engagement for the Term. It is however acknowledged and agreed between the Parties that ▇▇▇▇▇▇ ▇▇▇▇▇▇▇ will participate in a limited number of other activities at ▇▇▇▇▇ and also participate in a limited number of other engagements on behalf of ▇▇▇▇▇, subject to no conflict of interest between Crown and such other clients of ▇▇▇▇▇. ▇▇▇▇▇ and GKn are not obliged to carry out consultant services beyond what is set out above. GKn shall, however perform such additional services as from time to time is required by Crown in writing if these additional services are of a similar nature as the services and are reasonably related to the services. If GKn provides any such additional services, the provisions of this agreement, including the rates applicable to the Services shall apply unless otherwise explicitly stated in the written instructions by Crown.
Title Description. 4.1.15 Fire In accordance with the Pressure Equipment Directive, the case of fire is not required to be taken into account (as a precaution) for the design of pressure relief devices, as long as there is no fire load present within the meaning of this Code. The requirement given in the Pressure Equipment Directive, Annex I, Section 2.12 for external fire refers to the damage limitation level (c.f. Annex …) and is not intended to be used for the pressure limitation in normal operation (Pressure Equipment Directive Guideline 5/2 [2]). A fire load is considered to be a combustible substance in the vicinity of a helium cryostat, which represents a potential risk to the pressure vessel in the case of fire. Due to the heat transmission in the event of a fire, hazards may arise from the fire load by the touch of flames or thermal radiation. The consideration of fire would yield excessive oversizing of pressure relief devices, causing e.g. leakage and instable operation (chatter) with reduced discharge capacity and damage of spring-loaded pressure relief valves. It is therefore recommended to prevent the risk of fire in the vicinity of helium cryostats by appropriate measures such as fire prevention, fire protection and firefighting measures.
Title Description. Brew Mobile Platform Shall have the meaning given to it in Exhibit 1 to this Appendix B and LICENSEE’s use of Brew Mobile Platform shall be subject to the rights and restrictions as set forth therein. Camera Security SW Means QTI’s software that improves the security of image transmission between a standard RGB or IR camera and the Trusted Execution Environment for protected eye-based authentication or other uses. LICENSEE’s use of the Camera Security SW requires a Cryptographic Activation Certificate (as defined in Exhibit 5 to this Appendix B), use of which shall be subject to the restrictions set forth therein. CMX SW Means QTI’s Compact Media Extensions software. The CMX SW enables designated QTI ASICs to control the display of textual and/or graphical and/or animation and/or audio output while simultaneously synthesizing music and/or other sounds in a time sequenced manner. eMBMS Client SW Means the eMBMS (evolved Multimedia Broadcast Multicast Service) device service layer client software (including the PCAP tool and built-in Raptor 10 and Raptor Q decoders). QTI may, at its sole discretion, include additional features in eMBMS Client SW. Use of the additional features may be subject to an additional Incremental Fee. Hardware Token SW Means QTI’s software that provides authenticated hardware-level device information such as unique device ID, boot and debug configuration, trusted location, device health state, etc. LICENSEE’s use of the Hardware Token SW requires a Cryptographic Activation Certificate (as defined in Exhibit 5 to this Appendix B), use of which shall be subject to the restrictions set forth therein.
Title Description. 87058685 SHOWGROW Business advice and information in the agricultural field; Business efficiency advice in the agricultural field; Systemization of information into computer databases; Advice in the running of establishments as franchises in the agricultural field; Business consulting services in the agricultural field; Services rendered by a franchisor, namely, assistance in the running agricultural enterprises; all the foregoing in the agricultural field. 87975172 SHOWGROW Agricultural services, namely, soil sampling and crop observing for analysis purposes; Franchising services, namely, planning and design of information technology systems for business franchises; Computer services, namely, remote management of the information technology (IT) systems of others; Hosting an online community website featuring shared communications between community members interested in personal and small business computer information security; Planning, design and management of information technology systems; Professional consulting services and advice about agricultural chemistry. Agricultural services, namely, planting, growing, fertilizing, pruning and picking flowering plants for others; Agriculture and horticulture services, namely, plant selection and propagation of plants, plant material, and produce in connection with commercial rooftop soil farms; Pest control services for agriculture, horticulture and forestry. 87976709 SHOWGROW Hats; shirts; shirts and short-sleeved shirts; sweatshirts; T-shirts; athletic shirts; graphic Tshirts; ▇▇▇▇▇▇ shirts; hooded sweatshirts; hooded sweat shirts; knit shirts; long-sleeved shirts; open-necked shirts; polo shirts; short-sleeve shirts; short-sleeved shirts; short-sleeved or long-sleeved T-shirts; sleep shirts; sport shirts; sports shirts; sweat shirts; tee-shirts; wearable garments and clothing, namely, shirts; woven shirts. FIRST USE: 20151214. FIRST USE IN COMMERCE: 20151214. Bottled drinking water. FIRST USE: 20151214. FIRST USE IN COMMERCE: 20151214. The following Optional Services may be requested from time to time by Licensee. These Optional Services will result in additional charges and fees as set forth pursuant to separate agreements.
Title Description. 4.1.9 Power failure Power failure result in a lack of cooling power that compensates the heat load in cryostats during normal operation, thus causing pressure increase. In addition, power failure prevents the normal operation of control valves and other actuators.
4.1.10 Pressure surge Pressure surge is created by a sudden fluid velocity change that causes instable conditions. The fluid velocity change can be generated by e.g. starting/stopping pumps, opening/ closing valves or reductions in line size.
4.1.11 Freezing Ice formation can occur both inside and outside helium cryostats. For instance, hazardous freezing of nitrogen can occur due to over-filling of liquid nitrogen insulated helium bath cryostats, disabling the pressure relief of the nitrogen system. Further, freezing of remaining liquid nitrogen can occur when purging pre-cooled circuits with gaseous helium. Another problematic scenario is ice formation due to the cool-down of leaking pressure relief devices that can cause malfunction or even blockage. On the other hand, ambient air can leak through pressure relief devices of sub- atmospheric helium systems, causing internal blockage due to freezing.
4.1.12 Backflow Backflow can occur when connecting systems of different pressure, e.g. during transfer of liquid helium from storage Dewars into cryostats. The backflow of warm gas can cause a sudden evaporation of liquid helium.
4.1.13 Other sources of excessive pressure Other sources of pressure increase in helium cryostat include, for example, the lack of cooling due to cryoplant malfunction, human errors, control errors and non-standard operation of valves.
4.1.14 Earthquake Earthquake scenarios typically affect the mechanical design of helium cryostats (regulated e.g. in EN 13445), rather than the design of pressure relief devices. Nevertheless, earthquakes can trigger a break of insulating and beamline vacua through cryostat displacement and damage of connecting bellows.