Kowloon Development Office Territory Development Department, Hong KongComprehensive Feasibility Study Agreement • July 31st, 2001
Contract Type FiledJuly 31st, 2001dredging. Two control stations with one at the upstream location of the box culvert and one at the open water near the box culvert outlet would be selected. One monitoring station would be located within the section of the box culvert. Biweekly monitoring of the DO levels at the control and monitoring stations would be carried out. When the measured DO level at the monitoring station is below 2mg/L, additional measurement should be carried out on the next day. It is recommended that the action plan should be triggered to implement maintenance dredging under the following conditions: