Elementary neutralization unit definition

Elementary neutralization unit means a device which:
Elementary neutralization unit means a device of which the following is true:
Elementary neutralization unit means a device

Examples of Elementary neutralization unit in a sentence

  • Elementary neutralization unit" means a device which is used on site for neutralizing wastes that are hazardous solely because they exhibit the corrosivity characteristic defined in Chapter 850 of the department rules or are listed in section 3(C) of Chapter 850 solely for this reason and meets the definition of tank, tank system, container, transport vehicle or vessel in 40 CFR 260.10.

  • Elementary neutralization unit" means a device which is used on site for neutralizing wastes that are hazardous solely because they exhibit the corrosivity characteristic defined in 06-096 C.M.R. ch.

  • Elementary neutralization unit" means a device which is used on site for neutralizing wastes that are hazardous solely because they exhibit the corrosivity characteristic defined in Chapter 06-096 C.M.R. ch.


More Definitions of Elementary neutralization unit

Elementary neutralization unit means a container or tank used for neutralizing wastes that are hazardous only because they exhibit the corrosivity characteristic defined in s. NR 661.22, or they are listed in subch. D of ch. NR 661 only for corrosivity.
Elementary neutralization unit means a device that is following both of the following requirements:
Elementary neutralization unit means a device that is in compliance with both of the following requirements:
Elementary neutralization unit means a device which both:
Elementary neutralization unit means a device which: Is used for neutralizing wastes which are dangerous wastes only because they exhibit the corrosivity characteris- tics defined in WAC 173-303-090 or are listed in WAC 173-
Elementary neutralization unit means a deviceof which the following is true:
Elementary neutralization unit. This SWMU comprises several areas. The effluent generated during the rinsing and refilling of drums in the corrosive repackaging building flows into a drain in the floor. The effluent then flows from the drain through a PVC pipe to a sump, which is located just north of the corrosive repackaging building. The sump is an in-ground unit with a 180- gallon capacity. The inner container is constructed of a 3 1/8-inch thick polyethylene liner; the outer container is concrete. A portable electric pump pumps the effluent from the sump through PVC pipe to the elementary neutralization tank located approximately 20 feet east of the sump. The neutralization tank is situated within the large tank farm and surrounded by concrete- containment diking. The tank is constructed of polyethylene and has a 6,000-gallon capacity. If necessary, the pH of the effluent is adjusted to between 6 and 10 and then released into the sanitary sewer. This unit is not RCRA-regulated, as elementary neutralization units are exempt. The in-ground sump has been disconnected from the neutralization system and filled with sand, gravel, and concrete. The sump remains in-place, but it is now inoperable. The new neutralization system in the same general location and is now entirely aboveground.