{"component": "definition", "props": {"groups": [{"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB and which is not normally energized, but which can become electrically energized under isolation failure conditions. This includes parts under a cover that can be removed without using tools.", "samples": [{"hash": "jcImRPm1Aj1", "uri": "/contracts/jcImRPm1Aj1#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Conditions of Approval and Reciprocal Recognition of Approval for Motor Vehicle Equipment and Parts", "score": 35.6456871033, "published": true}, {"hash": "gZidDGqC2iq", "uri": "/contracts/gZidDGqC2iq#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Conditions of Approval and Reciprocal Recognition of Approval for Motor Vehicle Equipment and Parts", "score": 35.616809845, "published": true}, {"hash": "drHwIS1upS8", "uri": "/contracts/drHwIS1upS8#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 34.5817260742, "published": true}], "size": 91, "hash": "400f70a128e63de6f657f82e9ccdea34", "id": 1}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB, and which is not normally energized, but which can become electrically energized under isolation failure conditions. This includes parts under a cover that can be removed without using tools.", "samples": [{"hash": "dUZaOgjX9gS", "uri": "/contracts/dUZaOgjX9gS#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 36.2334518433, "published": true}, {"hash": "ja0KpfLkA1i", "uri": "/contracts/ja0KpfLkA1i#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles", "score": 33.2111740112, "published": true}, {"hash": "ilP9m2pPQza", "uri": "/contracts/ilP9m2pPQza#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles", "score": 27.2915802002, "published": true}], "size": 77, "hash": "f244450804e25f22ccc23ae9690e4b00", "id": 2}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-ipxxb", "type": "definition", "offset": [75, 91]}], "snippet": "means the conductive part which can be touched under the provisions of the protection IPXXB, and which becomes electrically energized under isolation failure conditions. This includes parts under a cover that can be removed without using tools.", "samples": [{"hash": "4kPyiuXhGGo", "uri": "/contracts/4kPyiuXhGGo#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 24.6160621643, "published": true}, {"hash": "lWpTyVx4drd", "uri": "/contracts/lWpTyVx4drd#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 24.0513343811, "published": true}, {"hash": "ch0lQ0kV1bT", "uri": "/contracts/ch0lQ0kV1bT#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 24.0513343811, "published": true}], "size": 59, "hash": "0eed82afce269903a895a93d50e760c8", "id": 3}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB, and which becomes electrically energized under isolation failure conditions.", "samples": [{"hash": "dOAJEkOlWvY", "uri": "/contracts/dOAJEkOlWvY#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 21.6091709137, "published": true}, {"hash": "gX8COt30vqq", "uri": "https://www.unece.org/fileadmin/DAM/trans/main/wp29/RESS-05-07e.doc", "label": "Amendment", "score": 14.3073234558, "published": false}, {"hash": "44vGN9M7JBv", "uri": "https://unece.org/DAM/trans/main/wp29/RESS-05-04e.doc", "label": "unece.org", "score": 11.3477067947, "published": false}], "size": 37, "hash": "e91b9a0ae8fe5fd0ff6aa4172f141c6a", "id": 4}, {"snippet_links": [], "snippet": "means conductive part which can be touched, and which only becomes electrically energized under failure conditions,", "samples": [{"hash": "2iOsmjebWQD", "uri": "/contracts/2iOsmjebWQD#exposed-conductive-part", "label": "Regulation 95 Concerning the Approval of Vehicles Regarding the Protection of Occupants in the Event of a Lateral Collision", "score": 26.5140323639, "published": true}, {"hash": "4DMR6BVX1XV", "uri": "/contracts/4DMR6BVX1XV#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 21.0095825195, "published": true}, {"hash": "dGAcWFTxigx", "uri": "/contracts/dGAcWFTxigx#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles", "score": 21.0, "published": true}], "size": 4, "hash": "98145b02a11fe1f5e2b5917d386145c5", "id": 5}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}, {"key": "external-electric-power-supply", "type": "definition", "offset": [183, 213]}, {"key": "alternating-current", "type": "definition", "offset": [224, 243]}, {"key": "direct-current", "type": "definition", "offset": [252, 266]}, {"key": "the-vehicle", "type": "clause", "offset": [305, 316]}, {"key": "root-mean-square", "type": "definition", "offset": [476, 492]}, {"key": "high-voltage-bus", "type": "definition", "offset": [506, 522]}, {"key": "electrical-circuit", "type": "definition", "offset": [534, 552]}, {"key": "coupling-system-for-charging-the-reess", "type": "definition", "offset": [568, 606]}, {"key": "indirect-contact", "type": "definition", "offset": [644, 660]}, {"key": "live-parts", "type": "definition", "offset": [728, 738]}, {"key": "normal-use", "type": "clause", "offset": [810, 820]}, {"key": "work-place", "type": "definition", "offset": [839, 849]}, {"key": "the-space", "type": "definition", "offset": [858, 867]}, {"key": "monitoring-system", "type": "definition", "offset": [1061, 1078]}, {"key": "the-device", "type": "clause", "offset": [1086, 1096]}, {"key": "electrical-chassis", "type": "definition", "offset": [1176, 1194]}, {"key": "open-type-traction-battery", "type": "definition", "offset": [1202, 1228]}, {"key": "related-to", "type": "definition", "offset": [1425, 1435]}, {"key": "service-disconnect", "type": "clause", "offset": [1562, 1580]}, {"key": "electrical-components", "type": "clause", "offset": [1682, 1703]}, {"key": "fuel-cell-stack", "type": "definition", "offset": [1726, 1741]}, {"key": "solid-insulator", "type": "definition", "offset": [1749, 1764]}, {"key": "for-the-purpose-of", "type": "definition", "offset": [1970, 1988]}, {"key": "working-voltage", "type": "definition", "offset": [2007, 2022]}, {"key": "as-specified", "type": "clause", "offset": [2105, 2117]}, {"key": "vehicle-manufacturer", "type": "definition", "offset": [2125, 2145]}, {"key": "normal-operating-condition", "type": "definition", "offset": [2280, 2306]}, {"key": "agricultural-tractor", "type": "definition", "offset": [2314, 2334]}, {"key": "with-regard-to", "type": "clause", "offset": [2340, 2354]}, {"key": "vehicle-speed", "type": "definition", "offset": [2400, 2413]}, {"key": "power-output", "type": "definition", "offset": [2524, 2536]}, {"key": "design-speed", "type": "definition", "offset": [2597, 2609]}, {"key": "characteristics-of", "type": "definition", "offset": [2625, 2643]}, {"key": "functional-safety", "type": "clause", "offset": [2763, 2780]}, {"key": "unacceptable-risk", "type": "definition", "offset": [2803, 2820]}, {"key": "physical-injury", "type": "definition", "offset": [2824, 2839]}, {"key": "damage-to-the", "type": "clause", "offset": [2846, 2859]}, {"key": "caused-by", "type": "clause", "offset": [2910, 2919]}, {"key": "electronic-systems", "type": "clause", "offset": [2997, 3015]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB, and which becomes electrically energised under isolation failure conditions; 2.15 \u2018external electric power supply\u2019 means an alternating current (AC) or direct current (DC) electric power supply outside of the vehicle; 2.16 \u2018high voltage\u2019 means the classification of an electric component or circuit, if itsworking voltage is > 60 V and \u2264 1 500 V DC or > 30 V and \u2264 1 000 V AC root mean square (rms); 2.17 \u2018high voltage bus\u2019 means the electrical circuit, including the coupling system for charging the REESS that operates on high voltage; 2.18 \u2018indirect contact\u2019 means the contact of persons with exposed conductive parts; 2.19 \u2018live parts\u2019 means the conductive part(s) intended to be electrically energised in normal use; 2.20 \u2018Operator\u2019s work place\u2019 \u2013means the space in the tractor for operator accommodation bounded by the barriers and enclosures provided for protecting the powertrain from direct contact with live parts; 2.21 \u2018on-board isolation resistance monitoring system\u2019 means the device which monitors the isolation resistance between the high voltage buses and the electrical chassis; 2.22 \u2018open type traction battery\u2019 means a liquid type battery requiring refilling withwater and generating hydrogen gas released to the atmosphere; 2.23 \u2018protection degree\u2019 means the protection provided by a barrier or enclosure related to the contact with live parts by a test probe, such as a jointed test finger (IPXXB) or a test wire access probe (IPXXD); 2.24 \u2018service disconnect\u2019 means the device for deactivation of the electrical circuit for thepurpose of servicing or checking electrical components such as the REESS and fuel cell stack; 2.25 \u2018solid insulator\u2019 means the insulation coating of wiring harnesses insulating live parts against direct contact from any direction of access, covers insulating live parts of connectors, as well as varnish or paint applied for the purpose of insulation; 2.26 \u2018working voltage\u2019 means the highest value of an electrical circuit voltage root-mean- square (rms) as specified by the vehicle manufacturer for each separate and galvanically isolated circuit, which may occur between any conductive parts in open circuit conditions or under normal operating condition; 2.27 \u2018Agricultural tractor type with regard to maximum continuous rated or net power and/or vehicle speed limitation by design\u2019 means vehicles which do not differ in such essential respects as the maximum continuous power output of the electric motor(s) and/or engine, the vehicle maximum design speed and the design characteristics of devices and methodology employed to effectively limit the vehicle\u2019s achievablemaximum speed and/or power output; 2.28 \u2018functional safety\u2019 means the absence of unacceptable risk of physical injury or of damage to the health of persons or to property owing to hazards caused by mal- functional behaviour of mechanical, hydraulic, pneumatic, electrical or electronic systems, components or separate technical units;", "samples": [{"hash": "jNvDmoGxaDG", "uri": "https://morth.nic.in/sites/default/files/ASI/AIS-168.pdf", "label": "morth.nic.in", "score": 6.4277892113, "published": false}, {"hash": "5pgYwIZc459", "uri": "https://hmr.araiindia.com/api/AISFiles/D2%20Draft%20of%20AIS%20168_EV%20Agri_Tractors_11c411ff-abbc-4d0a-8df5-666ff99e4819.pdf", "label": "hmr.araiindia.com", "score": 6.3990416527, "published": false}], "size": 2, "hash": "4c015c3b9e0b140e5bd10596885608f7", "id": 6}, {"snippet_links": [], "snippet": "means a conductive part which can readily be touched and which is not normally live, but which may become live under fault conditions;", "samples": [{"hash": "dCzgr1Swlnc", "uri": "https://www.eijammu.in/pdf/ceijk25jan25_1.pdf", "label": "www.eijammu.in", "score": 19.9533824921, "published": false}, {"hash": "3XmRkO0Eg4Y", "uri": "https://cea.nic.in/wp-content/uploads/notification/2023/06/pdf_100_183_English.pdf", "label": "cea.nic.in", "score": 11.729637146, "published": false}], "size": 2, "hash": "6df01d74f89fa66c85db1b29ee21c65d", "id": 7}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB, and which is not normally energized, but which can become electrically energized under isolation failure conditions. This includes parts under a cover that can be removed without using tools.\" Paragraph 2.16.(former), renumber as paragraph 2.21. Paragraphs 2.18. to 2.19. (former), renumber as paragraphs 2.22. to 2.23. Paragraph 2.17.(former), renumber as paragraphs 2.24. Paragraph 2.20.(former), renumber as paragraph 2.25. and amend to read:", "samples": [{"hash": "A7JVqoWUP7", "uri": "/contracts/A7JVqoWUP7#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles", "score": 32.4695472717, "published": true}, {"hash": "g8JVDYv0Jue", "uri": "/contracts/g8JVDYv0Jue#exposed-conductive-part", "label": "Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles", "score": 26.7494869232, "published": true}], "size": 2, "hash": "fe3ba9b4138bd997b3c5354fa817122f", "id": 8}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB, and which is not", "samples": [{"hash": "kaguQEoGD0x", "uri": "https://unece.org/DAM/trans/doc/2019/wp29grsp/GRSP-66-34e.pdf", "label": "unece.org", "score": 9.9691991806, "published": false}], "size": 2, "hash": "7c340dd3a03826399a76e910447d2f90", "id": 9}, {"snippet_links": [{"key": "the-provisions-of-the", "type": "clause", "offset": [53, 74]}, {"key": "protection-degree-ipxxb", "type": "definition", "offset": [75, 98]}], "snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB and which becomes", "samples": [{"hash": "aBiE0fN2euw", "uri": "http://210.248.150.32/common/001150999.pdf", "label": "210.248.150.32", "score": 8.4168376923, "published": false}], "size": 1, "hash": "2f578affa0051abb2e083162d4337ca4", "id": 10}], "next_curs": "CmQSXmoVc35sYXdpbnNpZGVyY29udHJhY3RzckALEhpEZWZpbml0aW9uU25pcHBldEdyb3VwX3Y1NiIgZXhwb3NlZC1jb25kdWN0aXZlLXBhcnQjMDAwMDAwMGEMogECZW4YACAA", "definition": {"snippet": "means the conductive part which can be touched under the provisions of the protection degree IPXXB and which is not normally energized, but which can become electrically energized under isolation failure conditions. This includes parts under a cover that can be removed without using tools.", "title": "Exposed conductive part", "size": 279, "id": "exposed-conductive-part", "examples": [], "related": [["exposed-group", "Exposed group", "Exposed group"], ["exposed-person", "Exposed person", "Exposed person"], ["developmentally-disabled-person", "Developmentally disabled person", "Developmentally disabled person"], ["small-disadvantaged-business-concern", "Small disadvantaged business concern", "Small disadvantaged business concern"], ["exposed-workplace", "Exposed workplace", "Exposed workplace"]], "related_snippets": [], "updated": "2025-07-24T04:27:56+00:00"}, "json": true, "cursor": ""}}