Interior Partitions. Taped, finished and painted (two coats of flat latex, partitioning to be constructed with one layer of 1/2" drywall mounted on each side of 3 5/8" metal studs, extending to the finished ceiling height and having 2 1/2" vinyl base throughout.
Interior Partitions. All interior partitions are approximately 8'-6", taped, mudded, and sanded smooth and painted. CEILINGS: Eight foot six inch suspended 2' X 4' grid acoustic system in office areas. Tegular, "second look" 2' X 2' design. Semi-recessed chrome sprinkler escutcheons.
Interior Partitions. Standard interior office partitions are to be 8'-10" in height, non-load-bearing, 3-5/8" metal studs, with 1/2" gypsum board on each side. All gypsum wallboard partitions shall be taped, bedded, floated, textured, sanded and painted with two coats of water-base latex paint. Sound attenuation bxxxx will be provided within all walls around conference rooms and restrooms, Fiberglass batt insulation (2 1/2" thick) between studs for the full height of the wall.

Examples of Interior Partitions in a sentence

  • Interior Partitions: New interior walls shall be constructed of 3-5/8" x 26 Ga. metal studs at 16" O/C with 1/2" gypsum wallboard on both sides.

  • Interior Partitions separating conference rooms from private offices; conference rooms to conference rooms or open office areas shall be Full Height non-rated walls constructed with 3 5/8” x 20 gauge metal studs at 16” O.

  • Be sure to consult an architect or engineer who can calculate the additional weight of the new roof to determine if the structural framing system can bear the extra load.Energy- and Resource-Efficient StrategiesExterior Walls and Interior Partitions Concrete Masonry Units (CMU)CMU, also known as concrete blocks or cinderblocks, is a resource-efficient material for re- bricking exterior walls.

  • Interior Partitions will be constructed similar to above but shall extend full height from floor to underside of structure above with 5/8” Type “X” gypsum wallboard on each side of studs.

  • Interior Partitions Typical 9’ - 0” interior partitions shall extend from finished slab to finished ceiling.


More Definitions of Interior Partitions

Interior Partitions. One layer of ½” drywall mounted on each side of 3-5/8” metal studs extending 2” above the finished ceiling height. Taped, finished and painted (two coats) partitioning to be provided with 4” high birch wood baseboard, 1 lineal foot per 12 square feet.
Interior Partitions. Shall be 5/8" fire rated gypsum wallboard on 3 5/8" metal studs to the underside of suspended ceiling grid at 9'0" above finished floor. One Lineal foot of wall will be provided per 12 square feet of office area. Gypsum wallboard is taped, bedded and sanded to accept scheduled wall finish. Gypsum wallboard applications to the inside face of the exterior wall, in office areas only, shall extend to 10'0" above finish floor, applied to metal furring strips and be taped, bedded and sanded to accept scheduled wall finish. FLOOR COVERING: Shall be selected from either 30-32 oz. cut pile nylon or 22-26 oz. level loop nylon in building standard colors in office areas. Carpet shall be directly glued down on concrete floor slab. Carpet base shall be 4" carpet base in building standard color. Warehouse area concrete floor slabs shall be sealed. CEILING HEIGHTS/CEILING SUSPENSION SYSTEM AND ACOUSTICAL CEILING TILE: Shall be 24" x 48" lay-in panel in 15/16" exposed white suspended steel grid at 9'0" clear height in office area. The warehouse ceiling is exposed structure, unpainted, at clear height to bottom of bar joists. WALL FINISHES: Vinyl wall fabrics area available for up to 20% of office wall finish in Landlord's building standard colors and types. Two coats of scrubbable flat latex will paint on office walls in building standard paint manufacturers' colors, including up to 20% deep tone accent colors.
Interior Partitions. 3-5/8", 25 gauge metal studs at 24" O.C., with 1/2" GWB each side - slab to ceiling grid.
Interior Partitions. Interior partitions shall extend from floor level to the underside of ceiling grid. Interior partitions shall be constructed using 3-5/8" metal studs and 5/8" smooth finished gypsum board each side. Black "Raco" top track, shall be used at connection of walls to ceiling. INSULATION: Sound insulation shall be provided in walls surrounding conference and lunch rooms. Sound insulation includes ceiling and walls for the lab and test room spaces. Sound insulation around private offices is excluded. A 4' wide band of fiberglass batt insulation shall be provided above ceiling, centered above walls receiving insulation.
Interior Partitions. Standard interior office partitions shall be 8’-6” in height (ceiling height). Construction shall be non-load-bearing, with 3-5/8” metal studs, 25 gauge, 24” oc, and 5/8” gypsum board on each side. All gypsum board partitions shall be taped, bedded, floated, textured, sanded and painted. Three-inch thick sound attenuation xxxxx will be provided within all walls around conference rooms, with 3-1/2” thermal xxxxx laid over ceiling at wall junction located such that two feet of xxxxx are laying on each side of partition. The Landlord allowance provides for one linear foot of interior partition for each 36 square feet of leased space. Demising Partitions: Standard tenant separation partitions shall be 3-5/8”, 25-gauge metal studs, 16” oc, with 5/8” gypsum board on each side of wall to underside of structure. Sound attenuation xxxxx will be provided in all tenant demising walls. The Landlord allowance provides for demising partitions as required by the tenant plan.
Interior Partitions. Shall consist of 3-5/8" 25 gauge metal stud and track at 24" on center with 5/8" gypsum board, 8'6" in height with each side taped, finished, and ready for Paint. Each side shall receive One (1) coat of primer and One (1) coat of low-sheen or flat latex Paint (accents, mid-tones, or deep-tones are not provided for under the Building Standard Finish Allowance) and 2-1/2" base. DEMISING & CORRIDOR PARTITIONS: Shall be the same as interior partitions with the addition of a 2" sound attenuation blanket in the wall cavity and extended from finished floor slab to the underside of structure above. CEILING: Shall be 24" x 48" x 5/8" with exposed T-grid suspended acoustical tile. The grid will remain where possible. All tiles will be replaced. CARPET: Building standard shall be 28 ounce nylon carpet, glued down directly on the concrete floor without carpet pad ($22/sy allowance). Vinyl base throughout.
Interior Partitions. One layer 5/8 inch thick gypsum drywall on each side ------------------- of 2 1/2 inch, 25 gauge galvanized steel studs, full height from floor to ceiling, painted finish two sides.