Accuracy requirements Sample Clauses

Accuracy requirements. All standards, procedures and equipment used by the Engineer’s Surveyor shall be such that the results of the survey will be in compliance with Board Rule 663.15 as promulgated by the TBPLS.
AutoNDA by SimpleDocs
Accuracy requirements. The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times: Metering Type 1 ( Metering of circuits rated greater than 100MVA) Metering Type 2 (Metering of circuits not exceeding 100MVA) Metering Type 3 (Metering of circuits not exceeding 10MVA)
Accuracy requirements. Overall accuracy The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times:
Accuracy requirements. 4.2.1 Overall accuracy: The overall accuracy of the energy measurements at or referred to at the Defined Metering Point shall at all times be within the limits of error as shown:- 4.2.1.1 Active Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% * 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± 0.5% ± 0.7% ± 1.5% ± 1.0% Superseded * This requirement shall only apply where the energy transfers to be measured by the Import Meter and/or the Export Meter during normal operating conditions is such that measured current will be below 5% of the Rated Measurement Current (excluding zero) for periods equivalent to 10% or greater per annum.
Accuracy requirements. The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times: Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± ± ± ± 1.0% 0.5% 0.7% 1.5% Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± ± ± ± 2.0% 1.0% 1.5% 2.5% Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% 120% to 10% inclusive 1 1 0.5 lag and 0.8 lead ± ± ± 2.5% 1.5% 2.0%
Accuracy requirements. The matcher accuracy will vary as a function of the class of service (identification, forensic, and tactical) and the quality of the input images. Identification service accuracy requirements are typically higher than those for forensic services as the input images are typically of better quality for live scan enrollments than for latent lifts. • Accuracy terms-of-art have been undergoing an evolutionary change for the past few years. While reliability, true accept rate, false reject rate, and other terms are often used for access control systems and other biometric modalities (such as facial recognition), a consensus has developed in the international standards community around the terms true match rate and failure to match rate when discussing friction ridge matching on a large-scale. • For this project, accuracy will have four accuracy terms: DocuSign Envelope ID: 46E92DE6-41 F7-4244-8F8A-51 C8B2BE0792 Attachment A using the selectivity numbers in the table below. TP-TP 1 99.9% NIA ID Slaps-TP 1 99.8% NIA TP-LT 115 70%180% 12 LT-TP PLT-KP 115 70%180% 12 1/5 70%180% 14 KP-PLT 1/5 70%180% 14 Tactical TP-TP (with at least 2 prints, and fewer than IO prints, search records will be Fingerprint Acquisition Profile (FAP)-30 or better) l 99.5% 16 Requirement ID # Requirement AccuracyReq00 I The OC ABl System shall provide accuracy for submitted Transactions per the values in the table above while conforming to the response times requirement in section 5.5. The accuracy will be measured with a mutually agreed upon test set consisting of search and reference file images ofNlST Fingerprint Image Quality (NFIQ) level 3 or better and with vendor Best Practices being used.
Accuracy requirements. 4.2.1 Overall accuracy: The overall accuracy of the energy measurements at or referred to the Defined Metering Point shall at all times be within the limits of error as shown: 4.2.1.1 Active Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% * 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± 1.0% ± 1.5% ± 2.5% ± 2.0% Superseded * This requirement shall only apply where the energy transfers to be measured by the Import Meter and/or the Export Meter during normal operating conditions is such that the measured current will be below 5% of the Rated Measuring Current (excluding zero) for periods equivalent to 10% or greater per annum. 4.2.1.2 Reactive Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive 120% to 20% inclusive Zero 0.866 lag and 0.866 lead ± 4.0% ± 5.0% Superseded These limits of error for both Sections 4.2.1.1 and
AutoNDA by SimpleDocs
Accuracy requirements. The matcher accuracy will vary as a function of the class of service (identification, forensic, and tactical) and the quality of the input images. Identification service accuracy requirements are typically higher than those for forensic services as the input images are typically of better quality for live scan enrollments than for latent lifts. • Accuracy terms-of-art have been undergoing an evolutionary change for the past few years. While reliability, true accept rate, false reject rate, and other terms are often used for access control systems and other biometric modalities (such as facial recognition), a consensus has developed in the international standards community around the terms true match rate and failure to match rate when discussing friction ridge matching on a large-scale. • For this project, accuracy will have four accuracy terms: using the selectivity numbers in the table below. TP-TP 1 99.9% N/A ID Slaps-TP 1 99.8% N/A TP-LT 1/5 70% / 80% 12 LT-TP 1/5 70% / 80% 12 PLT-KP 1/5 70% / 80% 14 KP-PLT 1/5 70% / 80% 14 Tactical TP-TP (with at least 2 prints, and fewer than 10 prints, search records will be Fingerprint Acquisition Profile (FAP)-30 or better) 1 99.5% 16 Requirement ID # Requirement AccuracyReq001 The OC ABI System shall provide accuracy for submitted Transactions per the values in the table above while conforming to the response times requirement in section 5.5. The accuracy will be measured with a mutually agreed upon test set consisting of search and reference file images of NIST Fingerprint Image Quality (NFIQ) level 3 or better and with vendor Best Practices being used.
Accuracy requirements. The Data Provider shall ensure that the accuracy of aeronautical data is as specified in the Aeronautical Data Catalogue [ATM/ANS.OR.A.085 (b)(1)] [ADR.OPS.A.010 (b)].
Accuracy requirements. All surveying shall be based on the control network established under separate contract. The State will provide control monument datasheets to the Engineer’s Surveyor. All standards, procedures and equipment used by the Engineer’s Surveyor shall be such that the results of the survey will be in compliance with Board Rule 663.15 as promulgated by the TBPLS. DocuSign Envelope ID: C8AF675D-2526-41B2-938D-3D337F7E3DEC