Add Drop Multiplexer Sample Clauses

Add Drop Multiplexer. 4.1 Verizon will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Verizon will use a [MANUFACTURER, MODEL] Add Drop Multiplexer with firmware release of [X.X] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Verizon must provide Nettalk with fourteen (14) days advance written notice that describes the upgrade or change to its firmware and states the date on which such firmware will be activated in Verizon’s Add Drop Multiplexer. 4.2 Nettalk will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Nettalk will use a [MANUFACTURER, MODEL] Add Drop Multiplexer with firmware release of [X.X] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Nettalk must provide Verizon with fourteen (14) days advance written notice that describes the upgrade or change to its firmware and states the date on which such firmware or software will be activated in Nettalk’s Add Drop Multiplexer. 4.3 Nettalk and Verizon will monitor all firmware upgrades and changes to observe for any failures or anomalies adversely affecting service or administration. If any upgrade or change to firmware adversely affects service or administration of FM No. [XX], the firmware will be removed from the Add Drop Multiplexer and will revert to the previous version of firmware. 4.4 The Data Communication Channel shall be disabled between the Verizon and Nettalk Add Drop Multiplexers of FM No. [XX].
AutoNDA by SimpleDocs
Add Drop Multiplexer. 4.1 Frontier will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Frontier will use a ***MANUFACTURER, MODEL*** Add Drop Multiplexer with firmware release of [x.x] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Frontier must provide Xxxxx with fourteen (14) days advance written notice that describes the upgrade or change to its firmware and states the 4.2 Xxxxx will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Xxxxx will use a ***MANUFACTURER, MODEL*** Add Drop Multiplexer with firmware release of [x.x] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Xxxxx must provide Frontier with fourteen (14) days advance written notice that describes the upgrade or change to its firmware and states the date on which such firmware or software will be activated in Xxxxx 4.3 Xxxxx and Frontier will monitor all firmware upgrades and changes to observe for any failures or anomalies adversely affecting service or administration. If any upgrade or change to firmware adversely affects service or administration of FM No. ***FM #***, the firmware will be removed from the Add Drop Multiplexer and will revert to the previous version of firmware. 4.4 The Data Communication Channel shall be disabled between the Frontier and Xxxxx Add Drop Multiplexers of FM No. ***FM #***.
Add Drop Multiplexer. 4.1 Verizon will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Verizon will use a [MANUFACTURER, MODEL] Add Drop Multiplexer with firmware release of [X.X] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Verizon must provide Comcast with fourteen
Add Drop Multiplexer. 4.1 Frontier will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Frontier will use a [MANUFACTURER, MODEL] Add Drop Multiplexer with firmware release of [X.X] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Frontier must provide Onvoy with fourteen (14) days advance written notice that describes the upgrade or change to its firmware and states the date on which such firmware will be activated in Frontier’s Add Drop Multiplexer. 4.2 Onvoy will, at its own cost, obtain and install (at its own premise) its own Add Drop Multiplexer. Onvoy will use a [MANUFACTURER, MODEL] Add Drop Multiplexer with firmware release of [X.X] at the network level. Before making any upgrade or change to the firmware of its Add Drop Multiplexer, Onvoy must provide Frontier with fourteen

Related to Add Drop Multiplexer

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • Multiplexing Hardware or software you use to

  • Multiple Bedroom Spaces If this Housing Agreement expressly identifies more than one bedroom space in a multi-bedroom apartment as assigned to Resident on page 1, then: (a) references to a “space” or “spaces” will be deemed to refer to all of the spaces assigned to Resident, or to the entire apartment if all of the bedrooms in an apartment are assigned to Resident; and (b) if Resident is assigned fewer than all of the bedroom spaces in an apartment, use of common areas will continue to be shared with other residents of the apartment and any calculation of Resident’s share of any charges assessed pro rata to all residents of an apartment will be made by dividing the number of bedroom spaces assigned to Resident by the total number of occupied bedroom spaces within the apartment.

  • Number Resources, Rate Center Areas and Routing Points 8.1 Nothing in this Agreement shall be construed to limit or otherwise adversely affect in any manner either Party’s right to employ or to request and be assigned any Central Office Codes (“NXX”) pursuant to the Central Office Code Assignment Guidelines and any relevant FCC or Commission orders, as may be amended from time to time, or to establish, by Tariff or otherwise, Rate Center Areas and Routing Points corresponding to such NXX codes. 8.2 It shall be the responsibility of each Party to program and update its own switches and network systems pursuant to information provided in the LERG in order to recognize and route traffic to the other Party’s assigned NXX codes. Except as expressly set forth in this Agreement, neither Party shall impose any fees or charges whatsoever on the other Party for such activities. 8.3 Unless otherwise required by Commission order, the Rate Center Areas will be the same for each Party. During the term of this Agreement, Onvoy shall adopt the Rate Center Area and Rate Center Points that the Commission has approved for Frontier within the LATA and Tandem serving area. Onvoy shall assign whole NPA-NXX codes to each Rate Center Area unless otherwise ordered by the FCC, the Commission or another governmental entity of appropriate jurisdiction, or the LEC industry adopts alternative methods of utilizing NXXs. 8.4 Onvoy will also designate a Routing Point for each assigned NXX code. Onvoy shall designate one location for each Rate Center Area in which the Onvoy has established NXX code(s) as the Routing Point for the NPA-NXXs associated with that Rate Center Area, and such Routing Point shall be within the same LATA as the Rate Center Area but not necessarily within the Rate Center Area itself. Unless specified otherwise, calls to subsequent NXXs of Onvoy will be routed in the same manner as calls to Xxxxx’s initial NXXs. 8.5 Notwithstanding anything to the contrary contained herein, nothing in this Agreement is intended, and nothing in this Agreement shall be construed, to in any way constrain Onvoy’s choices regarding the size of the local calling area(s) that Onvoy may establish for its Customers, which local calling areas may be larger than, smaller than, or identical to Frontier’s local calling areas.

  • Non-Synchronous Generation The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the high-side of the generator substation at a power factor within the range of 0.95 leading to 0.95 lagging, unless the NYISO or the Transmission Owner in whose Transmission District the Small Generating Facility interconnects has established a different power factor range that applies to all similarly situated non-synchronous generators in the control area or Transmission District (as applicable) on a comparable basis, in accordance with Good Utility Practice. This power factor range standard shall be dynamic and can be met using, for example, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors, or a combination of the two. This requirement shall only apply to newly interconnecting non-synchronous generators that have not yet executed a Facilities Study Agreement as of September 21, 2016.

  • Synchronous Generation The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the Point of Interconnection at a power factor within the range of 0.95 leading to 0.95 lagging, unless the NYISO or the Transmission Owner in whose Transmission District the Small Generating Facility interconnects has established different requirements that apply to all similarly situated generators in the New York Control Area or Transmission District (as applicable) on a comparable basis, in accordance with Good Utility Practice.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Increment In the Classification Level decided according to Article L9.07.01 above, establish the correct number of full years of approved and certified teaching experience, such placement not to exceed the number of years of experience provided for in the Level concerned. (See Article L9.06)

  • DNS name server availability Refers to the ability of a public-­‐DNS registered “IP address” of a particular name server listed as authoritative for a domain name, to answer DNS queries from an Internet user. All the public DNS-­‐registered “IP address” of all name servers of the domain name being monitored shall be tested individually. If 51% or more of the DNS testing probes get undefined/unanswered results from “DNS tests” to a name server “IP address” during a given time, the name server “IP address” will be considered unavailable.

  • Apple and Android Devices The following terms apply when you use a mobile application obtained from either the Apple Store or Google Play (each an “App Distributor”) to access the Site:

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!