Applicable Countries Sample Clauses

Applicable Countries. This Warranty is applicable only in the countries listed below. LG Energy Solution is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. Due to the limited service scope, this warranty is not applicable in constituent countries of the listed countries. • Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, United Kingdom
AutoNDA by SimpleDocs
Applicable Countries. This ‘Warranty’ is applicable only in the countries listed as below. LG Energy Solution is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. • United States, Canada, Puerto Rico This ‘Warranty’ gives you specific legal rights, and you may also have other rights which vary from State to State. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
Applicable Countries. This warranty is applicable only in the countries listed as below, and ‘LG Energy Solution’ is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. • Germany Attachment 1. ‘Battery Technical SpecificationsAttachment 2. ‘Standard Conditions of Use’ Electrical Cell JH3 Nom. Voltage/ Operating Voltage Range 51.8 V / 42 ~ 58.8V Total Energy Capacity 13.048 kWh Max. Power / Max. Current 5 kW / 119 A Peak Power (for 3sec) / Peak Current (for 3sec) 7 kW / 166.7 A Peak Current excludes repeated short duration (less than 3 sec.) of current pattern. Peak Power for Backup Mode 11kW for 3sec Standard Charging Condition (CC) Charging Current 56.7 A Cut off condition (58.8 V) 12.6A @ 58.8V, Ambient 25℃ Std. Discharging Condition (CC) Discharge Current 56.7 A Cut off Condition Discharge Cut off voltage : 42 V Battery pack Round-trip Efficiency >95% (under specific condition) Communication Interface CAN 2.0b Standard ID (500kbps) DC Disconnect Circuit Breaker, Contactor, Fuse Environmental Installation location Indoor(Wall-mounted) / Outdoor (if installed outdoors, do not allow the battery pack to be exposed to direct sunlight and moisture) Temperature Operating Range (Optimal Range) -10 ~ 50 ℃ (15 ~ 30 ℃) Storage Rangea) 1) - 30℃ ~ 60℃ (acceptable for 7 days in total)2) - 20℃ ~ 45℃ (acceptable for the first 6 months)3) - 20℃ ~ 30℃ (acceptable for 7th month~12th month) Operating Humidity Rangeb) 5 ~ 95% RH, Non Condensing Altitude Max. 2,000m Cooling Strategy Natural convection Reliability & Certification Safety Cell UL1642 Battery Pack CE/ FCC / RCM / TUV (IEC 62619) Hazardous Materials Classification Class 9 Transportation UN38.3 (UNDOT) Ingress IP55 a) Storage Temperature Range is temperature range during transporting and storing the ‘Products’ until the installation b) Storage Humidity is exactly same as Operating Humidity, and if it falls outside of the range, corrosion may occur or insulation performance may be affected. ※ The ‘Products’ shall not be installed in an airtight enclosure or in an area without adequate air flow to support natural air convection cooling methods. The ‘Product’ shall not be installed in sleeping areas or near flammable materials.
Applicable Countries. This ‘Warranty’ is applicable only in the countries listed as below. LG Energy Solution is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. • Germany
Applicable Countries. If U.S. Member is a Party to the Agreement: The United States. If Canada VISA Member and/or Canada MasterCard Member is a Party to the Agreement: Canada. If International Member is a Party to the Agreement: Any country that International Member is legally and operationally able to provide processing services (for the avoidance of doubt Iran and Iraq and any countries subject to international or United States sanctions are specifically excluded). Master Services Agreement (v.1.8.21) Schedule D
Applicable Countries. The Applicable Countries for purposes of Processing Services shall be those listed in Schedule C. Provider may decline to process Transactions in an identified Applicable Country if Provider is not authorized or is not permitted under Laws or Payment Network Regulations to process such Transactions. If at any time Provider is processing Transactions in an identified Applicable Country and there are changes in Laws or Payment Network Regulations which result in Provider not being authorized or not being permitted to process such Transactions, Provider may upon written notice to Company cease to process such Transactions effective [***] following such notice or the date such changes in Laws or Payment Network Regulations become effective, whichever is sooner.
Applicable Countries. The Applicable Countries for purposes of Processing Services shall be those listed in Schedule C. Provider may decline to process Transactions in an identified Applicable Country if Provider is not authorized or is not permitted under Laws or Payment Network Regulations to process such Transactions. If at any time Provider is processing Transactions in an identified Applicable Country and there are changes in Laws or Payment Network Regulations which result in Provider not being authorized or not being permitted to process such Transactions, Provider may upon written notice to Company cease to process such Transactions effective ninety (90) days following such notice or the date such changes in Laws or Payment Network Regulations become effective, whichever is sooner.
AutoNDA by SimpleDocs
Applicable Countries. This Warranty is applicable only in the countries listed as below, and LG ENERGY SOLUTION is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. Due to the limited service scope, this warranty is not applicable in constituent countries of the listed countries.
Applicable Countries. This Warranty is applicable only in the countries listed as below, and LGC is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. • Austria, Belgium, Czech Republic, Denmark, Finland, France, Greece, Hungary, Ireland, Italy, Luxembourg, Netherlands, Norway, Poland, Portugal, Spain, Sweden, Switzerland, United Kingdom This limited warranty (hereinafter ‘Warranty’) specified below applies to LG Chem Lithium-ion battery and the Accessory Component (hereinafter ‘Products’) supplied by LG Chem, Ltd. (hereinafter ‘LG Chem’ or ‘Seller’) to End-user (hereinafter ‘Buyer’) through their Reseller. Following warranty is provided for the below product. Product Model Serial Number RESU13 EH048252P3S1BMAxxxxxxxxxx
Applicable Countries. This warranty is applicable only in the countries listed as below, and ‘LG Energy Solution’ is not responsible for any claims against this Warranty made in and/or based on the event occurred in any countries other than listed herein. • Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a repair, replacement, or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Attachment 1. ‘Battery Technical SpecificationsAttachment 2. ‘Standard Conditions of Use’ Electrical Cell JH3 Nom. Voltage/ Operating Voltage Range 51.8 V / 42 ~ 58.8V Total Energy Capacity 13.048 kWh Max. Power / Max. Current 5 kW / 119 A Peak Power (for 3sec) / Peak Current (for 3sec) 7 kW / 166.7 A Peak Current excludes repeated short duration (less than 3 sec.) of current pattern. Peak Power for Backup Mode 11kW for 3sec Standard Charging Condition (CC) Charging Current 56.7 A Cut off condition (58.8 V) 12.6A @ 58.8V, Ambient 25℃ Std. Discharging Condition (CC) Discharge Current 56.7 A Cut off Condition Discharge Cut off voltage : 42 V Battery pack Round-trip Efficiency >95% (under specific condition) Communication Interface CAN 2.0b Standard ID (500kbps) DC Disconnect Circuit Breaker, Contactor, Fuse Environmental Installation location Indoor(Wall-mounted) / Outdoor (if installed outdoors, do not allow the battery pack to be exposed to direct sunlight and moisture) Temperature Operating Range (Optimal Range) -10 ~ 50 ℃ (15 ~ 30 ℃) Storage Rangea) 1) - 30℃ ~ 60℃ (acceptable for 7 days in total)2) - 20℃ ~ 45℃ (acceptable for the first 6 months)3) - 20℃ ~ 30℃ (acceptable for 7th month~12th month) Operating Humidity Rangeb) 5 ~ 95% RH, Non Condensing Altitude Max. 2,000m Cooling Strategy Natural convection Reliability & Certification Safety Cell UL1642 Battery Pack CE/ FCC / RCM / TUV (IEC 62619)/UL1973 Hazardous Materials Classification Class 9 Transportation UN38.3 (UNDOT) Ingress IP55 a) Storage Temperature Range is temperature range during transporting and storing the ‘Products’ until the installation b) Storage Humidity is exactly same as Operating Humidity, and if it falls outside of the range, corrosion may occur or insulation performance may be affected. ※ The ‘Products’ shall not be installed in an airtight enclosure o...
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!