Battery Technical Specifications Sample Clauses

Battery Technical Specifications. Items RESU10H Prime (EH153064P8S1) RESU16H Prime (EH257064P8S1) Voltage Range Charge 420 ~ 450V Discharge 350 ~ 410V Usable Energy1) (at battery DC output) 9.6kWh 16.0kWh Max. Power / Max. Current 5kW / 14.3A 7 kW / 20A Peak Power (for 10sec) 7kWp 11kWp Standard Charging /Discharging Condition Charging Power Following Power limit under 0.3 CP @ 25±2℃ (77±3.6℉) Cut off Condition Charge Power limit = 0 or SoC 100% Discharging Current Following Power limit under 0.3 CP @ 25±2℃ (77±3.6℉) Cut off Condition Discharge Power limit = 0 or SoC 0% Round-trip Efficiency >90.3% (under specific condition) Communication Interface CAN 2.0B (500kbps), RS485 Environmental Installation Method Standing / Wall Mount Fixture Standing Installation Site Indoor2) / Outdoor Operating Temperature Range Discharge -20 ~ 50℃ (-4 ~ 122℉) -20 ~ 50℃(-4 ~ 122℉) Charge -10 ~ 50℃ (14 ~ 122℉) Optimal Range 15 ~ 30℃ (59 ~ 86℉) Storage Temperature Range (At shipping state) 1) - 30℃ ~ 60℃ (-22 ~ 140℉) (acceptable for 7 days in total)2) - 20℃ ~ 45℃ (-4 ~ 113℉) (acceptable for the first 6 months)3) - 20℃ ~ 30℃ (-4 ~ 86℉) (acceptable for 7th ~ 12th month) Operating/Storage Humidity Range 5 ~ 95%, RH (Non Condensing) Altitude Max. 2,000m (6562ft) Cooling Strategy Natural convection Reliability & Certification Safety Cell UL1642 Battery Pack CE/ FCC / RCM / IEC 62619/ UL1973/ IEC62477 Hazardous Materials Classification Class 9 Transportation UN38.3 (UNDOT) Ingress IP55 1) DOD 100%. DC/DC converter one way efficiency 97.5%. Ambient 77°F (25°C) 2) The ‘Products’ shall not be installed in an airtight enclosure or in an area without adequate air flow to support natural air convection cooling methods. The ‘Product’ shall not be installed in sleeping areas or near flammable materials.
AutoNDA by SimpleDocs

Related to Battery Technical Specifications

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Technical Specifications and Drawings a) The Goods and Related Services supplied under this Contract shall conform to the technical specifications and standards mentioned in Section VI, Schedule of Requirements and, when no applicable standard is mentioned, the standard shall be equivalent or superior to the official standards whose application is appropriate to the Goods' country of origin. b) The Supplier shall be entitled to disclaim responsibility for any design, data, drawing, specification or other document, or any modification thereof provided or designed by or on behalf of the Procuring Entity, by giving a notice of such disclaimer to the Procuring Entity. c) Wherever references are made in the Contract to codes and standards in accordance with which it shall be executed, the edition or the revised version of such codes and standards shall be those specified in the Schedule of Requirements. During Contract execution, any changes in any such codes and standards shall be applied only after approval by the Procuring Entity and shall be treated in accordance with GCC Clause 33.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!