Circuit Breaker. All expenditures that shall incurred towards packing, transport, inspection, testing charges etc. are to be borne by the PIA.
AutoNDA by SimpleDocs
Circuit Breaker. Bank, in its discretion, through the Compensation Committee, may decide that there will be no payout in a given year until the level of net income (as reported in the Corporation’s financial statements) earned from each business is at least $2 million (or whatever level as determined by the Compensation Committee of the Corporation).
Circuit Breaker. Make - As per approved make. Type - Microprocessor release air circuit breaker Rated voltage - 415 Volts Rated frequency - 50 Hz Rated current - 1600/( Icu=Icf=1sec 50 kA) 800A(Icu=Icf=1sec 50 kA) No. of pole - 3 Aux. Voltage for trip/close coil - 110 V DC Motor for spring charging Voltage - 240 V AC Protection unit - Equivalent to SR-18G with fault indication & thermal masonry. Interlocking arrangement electrically & mechanically with bus coupler & incomer. The minimum protection to provided for different type of circuit are listed below :-
Circuit Breaker. To install and maintain in good working condition at the Tenant's expense the circuit breaker(s) to the Tenant's electricity supply which are installed in the Premises and if the Tenant shall fail for whatever reason to install or maintain the same, then the Landlord may do so and the costs of installation and/or maintenance shall be a debt due from the Tenant to the Landlord and be recoverable forthwith as such. For the avoidance of doubt, the Tenant shall not be liable to maintain any other circuit breakers which are not installed in the Premises, notwithstanding that the same may be installed in relation to the electricity supply to the Premises.
Circuit Breaker i. Circuit breaker shall be three poles, single throw, air breaker type with stored energy, trip free mechanism & shunt trip. The circuit breaker of the outgoing feeder shall have an in built microprocessor base release, short circuit, over current & earth fault protection release. ii. Circuit breakers shall be draw out type, having SERVICE, TEST & ISOLATED position with positive indication for each position along with in built relay unit. iii. Circuit breaker of identical rating shall be physically & electrically interchangeable. iv. Circuit breaker shall be motor wound spring charged mechanism, motor voltage should be 240 V AC. For motor wound mechanism, spring charging shall take place automatically after each breaker closing operation. One open close-open operation of the circuit breaker shall be possible after failure of power supply to the motor. Power supply for this motor shall be taken from the output of auto changeover. v. Mechanical safety interlocking shall be provided to prevent the circuit breaker from being racked in or out of the service position when the breaker is closed. vi. Automatic safety shutters shall be provided to fully cover the female primary disconnects when the breaker is withdrawn. vii. Each breaker shall be provided with an emergency manual trip, mechanical ON-OFF indicator, an operation counter & mechanism charge/ discharge indicator. viii. In additional to the auxiliary contacts required for normal breaker operation & indication, each breaker shall be provided with following for interlocking purpose:- a) Position/ cell switch with 4 NO. + 4 NC contacts. These shall be available as spare for automation work. Control Supply :- 230V AC for closing, Tripping & indication lamps. b) Auxiliary switch, with 6 NO+ NC contact, mounted on the stationary portion of the switchgear & operated mechanically by a sliding level from the breaker, in SERVICE position. These shall be available as spare for automation work. ix. Limit / auxiliary switches shall be convertible type, that is, suitable for changing NO contact to NC & Vice-Versa.
Circuit Breaker. As defined by the National Fire Protection Association-70 2020 National Electric Code, a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
Circuit Breaker. As of the Measurement Date, no unearned RSUs may become Earned RSUs if as of such date there exists a material weakness in safety, soundness or compliance (e.g., a regulatory memorandum of understanding), at the Company level or the Bank level, as determined in the sole discretion of the Committee (a “Circuit Breaker”), such that a Circuit Breaker at the Bank level shall prevent the earning of RSUs for Participants employed by such Bank and that a Circuit Breaker at the Company level shall prevent the earning of RSUs by all Participants as of the Measurement Date; provided, however, that in the event a Circuit Breaker exists, RSUs that would become Earned RSUs but for the existence of the Circuit Breaker shall not be forfeited as of the Measurement Date, and may become Earned RSUs if the Circuit Breaker ceases to exist in its entirety prior to the second anniversary of the Measurement Date.
AutoNDA by SimpleDocs
Circuit Breaker. Each apartment has a circuit breaker box in the kitchen. If an electric outlet becomes overloaded, it automatically throws the circuit off. If this happens, wait a few minutes, then locate which switch shut off. Make sure whatever caused the overload has been removed and then flip the switch back on.
Circuit Breaker. Is anything else in the room failing to turn on? If so, check your service panel (breaker/fuse box) for a tripped breaker or blown fuse.
Circuit Breaker. Industries (Pty) Ltd t/a CBI-Electric: Low Voltage (registration number 1943/15747/07) of 1 Tripswitch Drive, Elandsfontein, Johannesburg, South Africa (hereinafter the “Seller”, as further defined below), to