Common use of Condition of operation, System Parameters Clause in Contracts

Condition of operation, System Parameters. Except where otherwise specified in the schedule of requirements, all cables shall be suitable for operation at the guaranteed max. Sustained rating throughout all the seasons of the year. The nominal A.C system voltages to which the cables will be connected are 11 KV. The highest operating voltages for this system will be 110% of the nominal value; the cable shall withstand the highest operating voltage and the nominal A.C system voltage. (Nominal system voltage 11KV, Highest system voltage 12kV, Fault Current rating 25kA for 3 Sec, Earth fault current rating 3 KA for 3 Sec)

Appears in 3 contracts

Samples: www.ideco.com.jo, www.ideco.com.jo, www.ideco.com.jo

AutoNDA by SimpleDocs

Condition of operation, System Parameters. Except where otherwise specified in the schedule of requirements, all cables shall be suitable for operation at the guaranteed max. Sustained rating throughout all the seasons of the year. The nominal A.C system voltages to which the cables will be connected are 11 KV. 33000 V. The highest operating voltages for this system will be 110% of the nominal value; the cable shall withstand with stand the highest operating voltage and the nominal A.C system voltage. (Nominal system voltage 11KV33KV, Highest system voltage 12kV36KV, Fault Current rating 25kA for 3 Sec, Earth fault current rating 3 KA for 3 Sec).

Appears in 2 contracts

Samples: www.ideco.com.jo, www.ideco.com.jo

Condition of operation, System Parameters. Except where otherwise specified in the schedule of requirements, all cables shall be suitable for operation at the guaranteed max. Sustained rating throughout all the seasons of the year. The nominal A.C system voltages to which the cables will be connected are 11 KV. 33000 V. The highest operating voltages for this system will be 110% of the nominal value; the cable shall withstand the highest operating voltage and the nominal A.C system voltage. (Nominal system voltage 11KV33Kv, Highest system voltage 12kV36kV, Fault Current rating 25kA for 3 Sec, Earth fault current rating 3 KA for 3 Sec)) .

Appears in 1 contract

Samples: www.ideco.com.jo

AutoNDA by SimpleDocs

Condition of operation, System Parameters. Except where otherwise specified in the schedule of requirements, all cables shall be suitable for operation at the guaranteed max. Sustained rating throughout all the seasons of the year. The nominal A.C system voltages to which the cables will be connected are 11 KV. 33000 V. The highest operating voltages for this system will be 110% of the nominal value; the cable shall withstand the highest operating voltage and the nominal A.C system voltage. (Nominal system voltage 11KV33KV, Highest system voltage 12kV36KV, Fault Current rating 25kA for 3 SecSec for (1 x 500 mm2) & 21.7 KA for 3 Sec for (1 x 400 mm2), Earth fault current rating 3 KA kA for 3 Sec).

Appears in 1 contract

Samples: www.ideco.com.jo

Time is Money Join Law Insider Premium to draft better contracts faster.