Continued Operation. 7.4.1.1. Test procedure Cycle the PRD (pressure triggered) according to Table 3, with water between 10 per cent and 100 per cent of the working pressure, at a maximum cyclic rate of 10 cycles per minute and a temperature of 82 °C ± 2 °C or 57 °C ± 2 °C. Table 3 — Test temperatures and cycles Temperature [°C] Cycles 82 2,000 57 18,000
Appears in 3 contracts
Samples: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles
Continued Operation. 7.4.1.1. Test procedure Cycle the PRD (pressure triggered) according to Table 3, with water between 10 per cent and 100 per cent of the working pressure, at a maximum cyclic rate of 10 cycles per minute and a temperature of 82 °C ± 2 °C or 57 °C ± 2 °C. Table 3 — Test temperatures and cycles Temperature [°C] Cycles 82 2,000 57 18,0003
Appears in 1 contract