Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety
End User License Agreement This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. xxxx://xxxxxxxxxxxxxxx.xxx/licenses/by-nc-nd/3.0/ You are free to: Share: to copy, distribute and transmit the work Under the following conditions: Attribution: You must attribute the work in the manner specified by the author (but not in any way that suggests that they endorse you or your use of the work).
Sublicense to Use the Scudder Trademarks As exclusive licensee of the rights to use anx xxxxxcense the use of the "Scudder," "Scudder Investments" and "Scudder, Stevens & Clark, Inx." xxxdemaxxx (xxgether, the "Scuddex Xxxxx"), xxx xerexx xxant the Trust a nonexclusive right xxx xxxlicense to use (i) the "Scudder" name and mark as part of the Trust's name (the "Fund Namx"), xxd (ii) the Scudder Marks in connection with the Trust's investment products xxx xxxvices, in each case only for so long as this Agreement, any other investment management agreement between you or any organization which shall have succeeded to your business as investment manager ("your Successor") and the Trust, or any extension, renewal or amendment hereof or thereof remains in effect, and only for so long as you are a licensee of the Scudder Marks, provided however, that you agree to use your best xxxxxxx to maintain your license to use and sublicense the Scudder Marks. The Trust agrees that it shall have no right to suxxxxxxxe or assign rights to use the Scudder Marks, shall acquire no interest in the Scudder Marks othxx xxxx the rights granted herein, that all of txx Xxxxt's uses of the Scudder Marks shall inure to the benefit of Scudder Trust Company xx xxxer and licensor of the Scudder Marks (xxx "Xrademark Owner"), and that the Trust shall nxx xxxxlenge the validity of the Scudder Marks or the Trademark Owner's ownership thereof. The Truxx xxxxher agrees that all services and products it offers in connection with the Scudder Marks shall meet commercially reasonable standards of duaxxxx, xs may be determined by you or the Trademark Owner from time to time, provided that you acknowledge that the services and products the Trust rendered during the one-year period preceding the date of this Agreement are acceptable. At your reasonable request, the Trust shall cooperate with you and the Trademark Owner and shall execute and deliver any and all documents necessary to maintain and protect (including but not limited to in connection with any trademark infringement action) the Scudder Marks and/or enter the Trust as a registered user thereof. Xx xxch time as this Agreement or any other investment management agreement shall no longer be in effect between you (or your Successor) and the Trust, or you no longer are a licensee of the Scudder Marks, the Trust shall (to the extent that, and as soon ax, xx xawfully can) cease to use the Fund Name or any other name indicating that it is advised by, managed by or otherwise connected with you (or your Successor) or the Trademark Owner. In no event shall the Trust use the Scudder Marks or any other name or mark confusingly similar therexx (xxxluding, but not limited to, any name or mark that includes the name "Scudder") if this Agreement or any other investment advisory agrexxxxx xetween you (or your Successor) and the Fund is terminated.
Developer License We grant you a non-assignable, non-sublicensable, non-exclusive, worldwide right and license for the number of Developer(s) indicated in the Order Form to install the Software on any number of Machines in order to internally use the Software to create, develop and test Applications. For clarity, a single Software license may be re-allocated to another Developer in the event that the original Developer is no longer employed by you or has been assigned to a new role where access to the Software will no longer be required on a permanent basis.
Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.
Server License We grant you a non-assignable, non-sublicensable, non-exclusive, worldwide right and license to internally use and install the Software on the number of Server(s) listed in the Order Form for Commercial purposes. Unless stated otherwise in the Order Form, for the purposes of this license grant, you may install the Software on one (1) Machine as a substitute for, and not in addition to, one (1) Server. The total count of Server(s) where the Software is installed must not exceed the number of licenses purchased on the applicable Order Form(s).
Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.
Unbundled Voice Loops (UVL) may be provisioned using any type of facility that will support voice grade services. This may include loaded copper, non-loaded copper, digital loop carrier systems, fiber/copper combination (hybrid loop) or a combination of any of these facilities. BellSouth, in the normal course of maintaining, repairing, and configuring its network, may also change the facilities that are used to provide any given voice grade circuit. This change may occur at any time. In these situations, BellSouth will only ensure that the newly provided facility will support voice grade services. BellSouth will not guarantee that Southern Telecom will be able to continue to provide any advanced services over the new facility. BellSouth will offer UVL in two different service levels - Service Level One (SL1) and Service Level Two (SL2).
Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Lightyear’s loop distribution elements onto BellSouth's feeder system.
Unbundled Sub-Loop Distribution Voice Grade (USLD-VG) is a copper sub- loop facility from the cross-box in the field up to and including the point of demarcation at the End User’s premises and may have load coils.