Determination of Coke Tonnage. All Coke Tonnage shall be weighed by track scales operated by Seller. Such scales shall have an accuracy of not less than 0.25% and shall be calibrated by an independent third party at a minimum of once per year or more often as required by the manufacturer’s instructions or Prudent Operating and Maintenance Practices, the cost of which calibration shall be an O&M Expense. Absent Manifest Error, such weight determinations shall be conclusive and binding on the Parties. All Coke Tonnage shall be adjusted to a *****% moisture content in accordance with the following formula: The actual moisture percentage content of Coke shall be determined in accordance with Section 5.1.
Appears in 2 contracts
Samples: Coke Purchase Agreement (SunCoke Energy Partners, L.P.), Coke Purchase Agreement (SunCoke Energy, Inc.)
Determination of Coke Tonnage. All Coke Tonnage shall be weighed by track scales operated by Seller. Such scales shall have an accuracy of not less than 0.25% and shall be calibrated by an independent third party at a minimum of once per year or more often as required by the manufacturer’s instructions or Prudent Operating and Maintenance Practices, the cost of which calibration shall be an O&M Expense. Absent Manifest Error, such weight determinations shall be conclusive and binding on the Parties. All Coke Tonnage shall be adjusted to a ****** % moisture content in accordance with the following formula: ***** The actual moisture percentage content of Coke shall be determined in accordance with Section 5.1.
Appears in 1 contract
Determination of Coke Tonnage. All Coke Tonnage shall be weighed by track scales operated by Seller. Such scales shall have an accuracy of not less than 0.25% and shall be calibrated by an independent third party at a minimum of once per year or more often as required by the manufacturer’s instructions or Prudent Operating and Maintenance Practices, the cost of which calibration shall be an O&M Expense. Absent Manifest Error, such weight determinations shall be conclusive and binding on the Parties. All Coke Tonnage shall be adjusted to a *****% moisture content in accordance with the following formula: Tons Sold = ***** ***** The actual moisture percentage content of Coke shall be determined in accordance with Section 5.1.
Appears in 1 contract
Determination of Coke Tonnage. All Coke Tonnage shall be weighed by track belt scales operated by Seller. Such scales shall have an accuracy of not less than 0.25% %, and shall be maintained and calibrated by an independent third party at a minimum of once per year or more often as required by in accordance with the manufacturer’s instructions or Prudent Operating and Maintenance Practicesinstructions, the cost of which calibration shall be an O&M Expense. Absent Manifest Error, such weight determinations shall be conclusive and binding on the Parties. All Coke Tonnage shall be adjusted to a *****% moisture content in accordance with the following formula: Tons Sold = Total Tons x (1 – actual percentage moisture content) ***** The actual moisture percentage content of Coke shall be determined in accordance with Section 5.1.
Appears in 1 contract
Samples: Coke Purchase Agreement