Engineering and Design Sample Clauses

Engineering and Design. The Developer is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: • ANSI C2-2017 National Electrical Safety Code • ASCE 48 Design of Steel Transmission Pole Structures • IEEE Std. 524 Guide to the Installation of Overhead Transmission Line Conductors • IEEE Std. 691 Guide for Transmission Structure Foundation Design and Testing • NYPP Tie-Line Ratings Task Force 1995 Report • ASCE Manual of Practice 113 Substation Structure Design Guide • IEEE Std. 80 Guide for Safety in AC Substation Grounding • ANSI C37, Standards Series for substations and circuit breakers • ANSI C57, Standards Series for power and Instrument Transformers • IEEE and ANSI standards for transmission lines and substations, as applicable. • National Grid, Con Edison, Orange & Rockland, Central Xxxxxx, NYSEG, NYPA, and Affected Transmission Owners local transmission design criteria, as applicable.
AutoNDA by SimpleDocs
Engineering and Design. The Developer is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: • ANSI C2-2017 National Electrical Safety Code • ASCE 48 Design of Steel Transmission Pole Structures • IEEE Std. 524 Guide to the Installation of Overhead Transmission Line Conductors • IEEE Std. 691 Guide for Transmission Structure Foundation Design and Testing • NYPP Tie-Line Ratings Task Force 1995 Report • ASCE Manual of Practice 113 Substation Structure Design Guide • IEEE Std. 80 Guide for Safety in AC Substation Grounding • ANSI C37, Standards Series for substations and circuit breakers • ANSI C57, Standards Series for power and Instrument Transformers • IEEE and ANSI standards for transmission lines and substations, as applicable. • National Grid, Consolidated Edison Company of New York, Inc., Orange & Rockland Utilities, Inc., Central Xxxxxx Gas & Electric Corporation, New York State Electric & Gas Corporation, New York Power Authority, and Affected Transmission Owners local transmission design criteria, as applicable.
Engineering and Design. Contractor shall provide all engineering and design services necessary for completion of the Project in conformity with this Agreement, including but not limited to (a) preparation of (i) the Project Design Book which shall form the basis of the design of the Project, (ii) conceptual design, and (iii) engineering and design necessary to describe and detail the Project and to optimize the Project heat balance, (b) provision of criteria for the detailed design by suppliers of equipment, materials and systems for incorporation into the Project, and (c) preparation of drawings, plans, bills of material, schedules and estimates. Contractor shall comply with the Electrical Interconnection Requirements and cooperate with the engineering efforts and otherwise accommodate the interface requirements of the Utility, the Fuel Supplier, all federal, state and local agencies, and all utilities serving the Project that are consistent with Prudent Utility Practices; provided, however, that in the event that such accommodation would require Contractor to perform studies or other tasks that are a material addition to the Services otherwise provided for in this Agreement, Contractor shall not be required to perform such material additional work hereunder unless a Scope Change Order has been issued by Owner with respect thereto in accordance with Article 12 hereof. Upon Owner's request, Contractor shall use all reasonable efforts to provide Owner and, at Owner's request, the Independent Engineer and the Utility with reasonable access to meetings between Contractor and its architects, engineers or Subcontractors regarding the construction of the Project (except to the extent such meetings involve contractual matters that do not substantially affect or relate to the performance of the Services hereunder), provided such access does not materially interfere with the progress of Contractor's work hereunder. Contractor agrees to timely provide Owner and, at Owner's request, the Independent Engineer and the Utility with such documents and other information as are reasonably necessary for the Independent Engineer and the Utility to review and evaluate the design of the Project. Without limitation to the foregoing, Contractor agrees to submit to Owner and the Utility the design for the Electrical Interconnection Facilities (or any addition, modification or replacement thereto) in a timely manner in accordance with Section 2.1.8.1 hereof so as to enable Owner to obtain the Utility's ap...
Engineering and Design. The Developer may elect to have the proposed extension designed by a duly registered Washington engineer of its own choosing, or by the District. Systems designed by persons other than the District must be reviewed and approved by the District before construction may commence on the extension. The District services in designing a system, or reviewing a system designed by the Developer’s engineer, are a cost to the District within the construction fee.
Engineering and Design. 8 6.1 NU's Obligations................................................................................8 6.2 NECOM's Obligations.............................................................................8
Engineering and Design. Contractor shall proceed with the engineering and design of the Project upon issuance of the Notice to Proceed under the Agreement. Contractor shall independently research applicable codes and engineering references to comply with City, County, State, and Federal requirements. Contractor shall provide Project design documents for review/comments/acceptance by the Owner per the requirements in the Minimum Technical Requirements (Exhibit 1). Systems should be designed so that they can preassembled/prepackaged as much as possible to make plug and play systems in an effort to reduce on site labor requirements. The use of prepackaged inverter/MV transformer skids, plug in combiner boxes are desired.
Engineering and Design. The Developer is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: • ANSI C2-2017 National Electrical Safety Code • ASCE 48 Design of Steel Transmission Pole Structures • IEEE Std. 524 Guide to the Installation of Overhead Transmission Line Conductors • IEEE Std. 691 Guide for Transmission Structure Foundation Design and Testing • NYPP Tie-Line Ratings Task Force 1995 Report • ASCE Manual of Practice 113 Substation Structure Design Guide • IEEE Std. 80 Guide for Safety in AC Substation Grounding • ANSI C37, Standards Series for substations and circuit breakers • ANSI C57, Standards Series for power and Instrument Transformers • IEEE and ANSI standards for transmission lines and substations as applicable
AutoNDA by SimpleDocs
Engineering and Design. Star Service has engineers on staff and can provide our customers with Engineering and Design services from the smallest improvement to a full-service Design Build application requiring full specifications and stamped drawings. In many situations our customers have structural and mechanical issues that can be resolved in minimal time without costly delays, and job shutdowns. Our Engineering services can provide Control Design, HVAC Design, Lab Safety System, and are able to provide the latest in Green Design.
Engineering and Design. The Contractor warrants and guarantees that it shall perform all of its engineering and design services in accordance with sound engineering practice, Governmental Approvals and applicable Laws and that, when complete, the Project will be free of all deficiencies caused by errors or omissions in engineering or design. For a period of one year from the earlier of Final Completion or the commencement of Commercial Operation, the Contractor shall, as the General Contractor's sole remedy for breach of this warranty, at its own expense correct any such efforts and omissions and resulting deficiencies in the Project as soon as reasonably possible after receipt of notice from the General Contractor specifying such deficiencies.
Engineering and Design. Contractor shall perform all engineering and design services for completion of the DB Work in conformity with the requirements of this Agreement. All engineering work of Contractor requiring certification shall be certified, and all Design Documentation requiring sealing shall be sealed, by professional engineers licensed and properly qualified to perform such engineering services in all appropriate jurisdictions, which engineers and their qualifications shall be subject to the review and approval procedures set forth in Section 2.1.5.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!