Fiber-Meet. 3.3.1 If the Parties Interconnect their networks pursuant to a Fiber-Meet, the Parties shall jointly engineer and operate a single Synchronous Optical Network (“SONET”) transmission system. Unless otherwise mutually agreed, this SONET transmission system shall be configured as illustrated in Exhibit A, and engineered, installed, and maintained as described in this Article III and in the Plan (as defined in Section 8.1). 3.3.2 Ameritech shall, wholly at its own expense, procure, install and maintain Optical Line Terminating Multiplexor (“OLTM”) equipment in the Ameritech Interconnection Wire Center (“AIWC”) identified for each LATA set forth on Schedule 2.1, in capacity sufficient to provision and maintain all logical trunk groups prescribed by Articles IV and V.
Appears in 3 contracts
Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement
Fiber-Meet. 3.3.1 If the Parties Interconnect their networks pursuant to a Fiber-Meet, the Parties shall jointly engineer and operate a single Synchronous Optical Network (“SONET”) transmission system. Unless otherwise mutually agreed, this SONET transmission system shall be configured as illustrated in Exhibit A, and engineered, installed, and maintained as described in this Article III and in the Plan (as defined in Section 8.1).
3.3.2 Ameritech shall, wholly at its own expense, procure, install and maintain Optical Line Terminating Multiplexor (“OLTM”) equipment in the Ameritech Interconnection Wire Center (“AIWC”” ) identified for each LATA set forth on Schedule 2.1, 2.1 in capacity sufficient to provision and maintain all logical trunk groups prescribed by Articles IV and V.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Fiber-Meet. 3.3.1 If the Parties Interconnect their networks pursuant to a Fiber-Meet, the Parties shall jointly engineer and operate a single Synchronous Optical Network (“SONET”) transmission system. Unless otherwise mutually agreed, this SONET transmission system shall be configured as illustrated in Exhibit A, and engineered, installed, and maintained as described in this Article III and in the Plan (as defined in Section 8.1).
3.3.2 Ameritech shall, wholly at its own expense, procure, install and maintain Optical Line Terminating Multiplexor (“OLTM”) equipment in the Ameritech Interconnection Wire Center (“AIWC”) identified for each LATA set forth on Schedule onSchedule 2.1, in capacity sufficient to provision and maintain all logical trunk groups prescribed by Articles IV and V.
Appears in 1 contract
Samples: Interconnection Agreement