Fire Protection System. Fire protection system requirements vary by governmental requirements per location and by insurance carrier requirements. Owner is responsible to provide the required fire protection system for the Plant. This may include storage tanks, pumps, underground fire water mains, fire hydrants, foam or water monitor valves, sprinkler systems, smoke and heat detection, deluge systems, or other provisions as required by governmental codes or Owner's insurance carrier's fire protection criteria. Design-Builder will provide assistance to the Owner on a "Time & Material" basis for design and/or construction of the fire Protection Systems required for the plant. TABLE 1 MINIMUM SOIL BEARING PRESSURE-RESPONSIBILITY OF OWNER REQUIRED ALLOWABLE SOIL BEARING PRESSURE DESCRIPTION (POUNDS PER SQUARE FOOT) ----------- ---------------------------------------- Grain Storage Silos 8,000 Xxxx Water lank 3,500 Methanator Feed Tank 3,500 Liquefaction Tank #1 3,500 Liquefaction Tank #2 3,500 Coal Combustor 4,000 Coal Storage Silo #1 6,000 Coal Storage Silo #2 6,000 Lime Silo 6,000 Coal Unloading Building 4,000 Boiler 4,000 Dust Collector 3,500 Fermentation Tank #1 4,000 Fermentation Tank #2 4,000 Fermentation Tank #3 4,000 Fermentation Tank #4 4,000 Beerwell 4,000 Whole Stillage Tank 3,500 Thin Stillage Tank 3,500 Syrup Tank 3,500 190 Proof Day Tank 3,000 200 Proof Day Tank 3,000 Denaturant Tank 3,000 Fire Water Tank 3,000 Denatured Ethanol Tank #1 4,000 Denatured Ethanol Tank #2 4,000 All Other Areas 3,000 TABLE 2 MAINTENANCE AND POWER EQUIPMENT - RESPONSIBILITY OF OWNER DESCRIPTION ADDITIONAL DESCRIPTION ----------- ---------------------- Spare Parts Spare parts Parts bins Misc. materials, supplies and equipment Shop supplies and equipment One shop welder One portable gas welder One plasma torch One acetylene torch One set of power tools Two sets of hand tools with tool boxes Carts and dollies Hoists (except centrifuge overhead crane) Shop tables Maintenance office furnishings & supplies Fire Extinguishers Reference books Safety manuals Safety cabinets & supplies, etc. Rolling stock Used 1 1/2 yard front end loader New Skid loader Used Fork lift Used Scissors lift, 30 foot Used Pickup truck Track Mobile EXHIBIT D LICENSE AGREEMENT THIS LICENSE AGREEMENT (this "License Agreement") is entered into and made effective as of the 9 day of Sept, 2005 ("Effective Date") by and between Red Trail Energy, LLC, a North Dakota limited liability company ("OWNER"), and ICM, Inc., a Kansas corpor...
Fire Protection System. CMRL has obtained approval of from Tamilnadu Fire Services for existing integrated fire protection system for whole infrastructure of Station including area of licensed Kiosks Spaces. Any augmentation to existing fire protection system, if required due to renovation of licensed Kiosks Spaces shall be done by the licensee at his own risk & cost as per relevant BIS Code of Practice and norms of CMRL & Tamilnadu Fire Services.
Fire Protection System. 1. Sprinkler piping shall be terminated at the rising mains. Upright and pendant sprinklers shall be provided in the Demised Premises.
Fire Protection System. A fire riser is constructed to meet applicable national and local Building code requirements. The fire protection water supply enters the Building underground at the fire control room on the main floor near the exterior of the Building. Wet standpipes rise vertically through the stairwells. Branch lines complete with sprinkler heads are installed in the building core. A main branch line (defined as 2- 1⁄2” in diameter or larger) is extended from the core into the tenant lease areas on each floor in two directions as part of the Base Building Improvements.
Fire Protection System. CMRL has obtained approval from Tamilnadu Fire Services for existing integrated fire protection system for whole infrastructure of Station including area of licensed Built up Shops/ Office Spaces. Underground water tank of 1 (one) lakh litre capacity and the other equipments including booster pump for fire safety are also available at station. Any augmentation to existing fire protection system, if required due to renovation of licensed Shops/ Office Spaces/space, shall be done by the licensee at his own risk & cost as per relevant BIS Code of Practice and norms of CMRL & Tamilnadu Fire Services.
Fire Protection System. All relevant fire protection components (i.e., branch piping, sprinkler heads, fittings, drains, pumps, tanks, sensors, control panels) with necessary intelligence to produce accurate plans, elevations, building/wall sections, riser diagrams, and schedules. All fire protection piping shall be modeled.
Fire Protection System. (a) Check all hydrant valves and if any valve is open than close it. Check that all suction and delivery connections are properly made.
Fire Protection System. 1. Upright sprinkler piping in the office area and fire rated doors for all shafts.
Fire Protection System. A fire protection system will be built with sprinklers on the roof of the shed with the corresponding cistern, pump room, in compliance with the local standard and regulation.
Fire Protection System. A. Fire protection is fed from a 6” service from the public water main. An in-line, vertical fire pump feeds two (2) 6” combined standpipes, to provide pressure for the sprinkler system.