Additional Resources The WLSC may establish workgroups that include other department representatives and/or subject matter experts. These subcommittees shall conform with rules established by the WLSC.
Financial Resources The Adviser has the financial resources available to it necessary for the performance of its services and obligations contemplated in the Pricing Disclosure Package, the Prospectus, and under this Agreement, the Investment Management Agreement and the Administration Agreement.
General Management In the discharge of its general duty to manage the successful performance of the Services, Vendor shall: 3.2.1.1. within thirty (30) calendar days of the Effective Date, identify to Citizens the primary and secondary management contacts responsible for the oversight and management of Services for Citizens; 3.2.1.2. ensure Vendor Staff tasked with management and oversight of the Services are available promptly to perform Services during Business Hours; 3.2.1.3. ensure each assigned Adjuster submits a time record directly to Vendor’s manager or point of contact. At any time during this Agreement, Citizens may require copies of time records from Vendor; 3.2.1.4. ensure that no Vendor Staff carries a weapon on their person while performing Services; 3.2.1.5. ensure that no Vendor Staff uses impairing drugs, chemicals, or alcohol while performing Services; 3.2.1.6. ensure that Vendor Staff avoid using their duties and obligations under this Agreement to engage in any conduct that could create either an actual or perceived conflict of interest, such as due to an ongoing business relationship with an entity other than Citizens that would enable Vendor Staff to receive an improper benefit or unfair competitive advantage; 3.2.1.7. ensure that the Services comply with the Best Claims Practices & Estimating Guidelines as applicable to each Service Category and any other policies or processes set forth by Citizens, including but not limited to: a. monitoring applicable file production on a weekly basis to determine compliance with Citizens’ production requirements; and, b. providing detailed reports to Citizens related to Vendor performance upon request.
Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.