Infrastructure Services. 1. It shall be mandatory for the Licensee to follow Green Building norms while doing the renovation/finishing/furbishing of the respective property business space(s).
2. The Internal distribution of electric power, air conditioning systems, fire fighting sprinklers, fire detection, advisable fire alarm panel etc. as per the norms required for the Licensed Space(s) shall be provided by the Licensee at his own cost. The Licensee shall be required to take prior approval from the respective departments of Maha-Metro regarding the use of available infrastructure like electricity, air conditioning etc. The licensee shall follow the Guidelines of National Building Code, codal provisions of relevant Indian standard Codes and “General Fitout Guidelines”, if any, issued by Maha- Metro and comply with the same and its further amendments as issued from time to time
3. The Licensee shall submit all plans / drawings and specification of material whatsoever including but not limited to construction, internal partitions, fire detection & fighting, flooring, lighting, electrical, signage advertisement panels etc; for approval of Maha- Metro before start of any work/s inside the Licensed Area. It shall be mandatory for the licensee to submit the notarised undertaking on Rs. 500/- stamp paper before start of any work/s inside the Licensed Area, stating that:
1. The material used in the premises will be non-combustible and shall be as per the Guidelines of National Building Code, and as per relevant Indian standard Codes.
2. Will be providing / installing all the mandatory fire frightening arrangement inside the licenced area. The Maha-Metro reserves the right not to give approval if it deems such works may act as a hindrance in the smooth functioning of its operations at the Project Site. All materials to be used including electrical materials should be fire resistant and should meet the minimum specifications as mentioned in the respective National Building Code applicable for metro stations and other relevant IS Codes. The prior approval of Maha-Metro is mandatory before commencement of the installation.
4. The Maha-Metro officials of Property Development Department, Civil Department, Electrical Department and MEP (Fire-Fighting) Department of the Maha-Metro will have full and unfettered access to inspect and check the materials before and after the installation, and during the license period. All instructions issued by them in this regard will be complied by Licensee in f...
Infrastructure Services. The Cloud Service includes infrastructure services as described in the SAP Commerce Cloud Services Description.
Infrastructure Services. (a) Services Components
(1) Mainframe Services Resources (A) Host CPU Resources (MIPS) Resource usage will be measured *. *. ARCs and RRCs apply to CPU resource usage and will be charged based on the rates set forth in Table C.1.2.a (Charges – by Country Retained).
Infrastructure Services. 21.1. The Concessionaire shall provide the Infrastructure Services as may be required to discharge its obligations under this Agreement (including Asset Management Plan set out in Schedule 2 Part 4 (Concession Specifications - Infrastructure Performance Measures)), the Ancillary Agreements and to comply with Laws, including the RSR Act, Applicable Requirements (including Environmental Law and the Astronomy Geographic Advantage Act, 21 of 2007), Consents, Safety Permits and the Fencing Act, 31 of 1963.
21.2. Infrastructure Services shall, subject to the provisions of clause 19.2 (Other Upgrade and Refurbishment Works), be undertaken at the sole risk and expense of the Concessionaire by one or more Certified Contractors. It is recorded that the performance of Infrastructure Services includes the undertaking of any refurbishment works as may be necessary or implicit in the execution of the Infrastructure Services.
21.3. The Concessionaire shall, on an annual basis for the duration of the Concession Term submit a written report to Transnet on its performance of the Infrastructure Services measured against the Concessionaire Annual Infrastructure Works Plan (set out in Schedule 2 Part 4 (Concession Specifications – Infrastructure Performance Measures) for the year under review ("Annual Maintenance Report"). If there is any shortfall between the actual performance of Infrastructure Services and the Concessionaire Annual Infrastructure Works Plan, the Concessionaire shall –
21.3.1. set the nature and extent of such shortfall, the reason therefor;
21.3.2. when and how the shortfall is to be made good also indicating that in the Concessionaire Annual Infrastructure Works Plan for the ensuing year; and
21.3.3. the consequence to the Rail Infrastructure or condition thereof as a result of the delay occasioned by the shortfall, and Transnet shall be entitled to physically verify any aspect of any Annual Maintenance Report.
21.4. Transnet shall be entitled, in intervals of 5 (five) years each and as part of a relevant performance review contemplated in clause 32.2 (Performance Reviews), to procure the undertaking of an interim maintenance survey by a Certified Contractor ("Interim Maintenance Survey") to -
21.4.1. review the actual maintenance carried out during the period since Effective Date, or the last Interim Maintenance Survey (as the case may be) to the current Interim Maintenance Survey for the Concession Assets;
21.4.2. review the programmed (or planned) maint...
Infrastructure Services. The PARTIES will negotiate the minimum information security parameters recommended for electronic data transfers, with each of the PARTIES being responsible for the costs, acquisition and installation of cryptography systems compatible with the necessary line capacity and the communications system of ORBITALL, in the data communication channels between the PARTIES. The PARTIES also agree that all data transmissions between them should be supported by cryptography programs.
Infrastructure Services. The PARTNER agrees to keep harmless ORBITALL and its Customers from any embarrassment caused by web pages or electronic mail messages containing shortcuts to other pages or unsolicited offers of products and services (such as links, banners, hot sites and spam) or whose content may be pornographic, offensive or contain any type of discrimination based on race, gender, creed or nationality. CLAUSE SEVENTEEN - CONTINGENCY PLAN
Infrastructure Services. The sites are 0X Xxxxxxxx Xxxxx, Xxxxxx, Xxxxxxxx and 00 Xxxxxxxxx Xxxxxxxx, Xxxxxxxx, Christchurch.
Infrastructure Services a.) Electricity:
(i) Single point 6 KVA single phase power connection shall be provided by DMRC. The differential for providing electrical infrastructure more than 2 KVA shall be borne by Licensee. Electrical Security Deposit for 6 KVA and recurring energy charges shall be charged from Licensee.
(ii) If any other electrical appliance other than Water ATM machine is found drawing electric power from the single point source then, electrical charges shall be billed @ twice of the monthly bill amount.
(iii) For electric supply released a declaration has to be signed by Licensee for compliance of DISCOM as per the rules governed by DERC & DMRC.
(iv) Licensee cannot avail power from any outside agencies/source.
(v) Up-keeping/proper maintenance of Water ATM machine/s with respect to electric wiring from single point source of DMRC lies with the Licensee.
(vi) Licensee shall indemnify DMRC for any loss/damage/short circuit/fire/electric shock caused during the operation of the Water ATM machine.
(vii) All DERC guidelines will be adhered to including provision of XXX energy Meter.
Infrastructure Services. Based on gathered requirements and from the technical partners’ experience, a list of gLite services which were needed in neuGRID was initially determined and progressively enriched from received feedback. As a consequence, the following grid services have been selected, tested and deployed: • VOMS: to manage the neuGRID community. • MyProxy to handle long running jobs. • LFC to reference all files stored in the grid. • DPM to store the imaging data and other physical files. • tBDII and sBDII services for the grid information system. • CE/WN and WMS/LB services to schedule and run jobs in the grid. VOMS, MyProxy, LFC, tBDII and WMS/LB are part of the Grid Coordination Center (i.e. GCC) as core services of the neuGRID infrastructure. Indeed, they can be seen as gLite core services under which all other neuGRID services can be added/mixed. The VOMS server is shared by the 2 sub- infrastructures (i.e. PoC and PROD) as it is able to deal with sub-groups. This is also the case for MyProxy, as it is only a proxy certificate repository into which users can dump their delegated credentials. Concerning LFC, tBDII and WMS/LB, there is one instance of each service per sub-infrastructure in order to avoid all potential resource sharing problems and to ease users’ access rights management. sBDII, DPM and CE/WN were installed on each of the Data Archiving and Computing Sites (DACS) to provide them with data storage and computing power capacity. This approach is considered to be a standard practice for gLite middleware deployment. MyProxy VOMS CA LFC WMS/LB tBDII CE/WN DPM sBDII DPM sBDII As it is presented in the project description of work document, “LEVEL 0” represents the “infrastructure ground truth” level, made of infrastructure core services, whereas “LEVEL 1” represents the Data Archiving and Computing Sites (DACS) hosting the physical resources used to store and compute data. Two partners are providing the core services of the neuGRID infrastructure, respectively: • MAAT which owns the GCC and one development DACS (for testing purposes), • PRODEMA which owns the Data Coordination Center (DCC). For the GCC, the deployed services are as follows: VOMS xxxx.xxxxx.xx xxx.xxxxx.xx LFC xxxx.xxxxx.xx tBDII xxxxxxx.xxxxx.xx MyProxy xxx.xxxxx.xx WMS + LB xxxxxx.xx-xxxx-xxxxxx0.xxxxx.xx CA For the development DACS made available by MAAT, the deployed services are as follows: DPM xx-xxxx-xxxxxx0.xxxxx.xx xxxx-xxxx.xxxxx.xx sBDII ng-maat-server9. xxxxx.xx CREAM XX xx-xxxx-se...
Infrastructure Services. Misys to provide development infrastructure services to include: • Development tools and platforms (including, without limitation, Microsoft). • ALM tools/platforms (including, without limitation, Collabnet). • Project Management tools & platform (including, without limitation, Clarity applications). Collabnet Licenses for Allscripts-Misys Healthcare to participate in the Misys Global ALM program. For purposes of clarification, these services include hosting, support and access to all of the foregoing tools and platforms for Allscripts development and support personnel.