Instrumentation/Control Systems Sample Clauses

Instrumentation/Control Systems. TANK CONTRACTOR shall recommend the necessary instrumentation and controls required to safely operate and protect each of the storage tanks. These recommendations shall be submitted to PURCHASER and shall include, as a minimum but without limitation, the following: • Tank Data Acquisition System (see below); • Tank wall temperature sensors (Cool Down); • Tank bottom temperature sensors (Cool Down); • Outer tank floor and suspended deck low temperature sensors; • Density/level/temperature sensor (servo type); • Tank level sensors (redundant, servo type); • High level switch; • Tank pressure transmitter (redundant); • Tank temperature profile sensors; • Vapor space temperature sensors; • Inner tank movement monitoring system; • Tank pressure/vacuum relief valves.** ** It is the TANK CONTRACTOR’s responsibility to size the pressure/vacuum relief valves. All electronic instruments shall be designed and wired to TANK CONTRACTOR-supplied junction boxes located at grade, 20 feet horizontally from the base of the tank (i.e. within the Battery Limits) and include: • Cable trays and supports; • Installation materials, including cables, tubes, conduits, junction boxes, etc. TANK CONTRACTOR shall provide calculations and certification for pressure/vacuum relief valves. TANK CONTRACTOR shall be responsible for installing control valves and other instrumentation shown within the boundary limits of TANK CONTRACTOR’s package on the referenced P&ID’s. TANK CONTRACTOR shall clearly identify the location and physical interconnection of this equipment on approval drawings submitted to PURCHASER. TANK CONTRACTOR shall design and supply running instrument air sub-headers (with isolation valves for take-offs) from TANK CONTRACTOR Battery Limits to those areas requiring this service. TANK CONTRACTOR shall perform calibration tests for all instruments provided by TANK CONTRACTOR or any Subcontractor or Sub-subcontractor for the Phase 2 Tanks. TANK CONTRACTOR shall provide additional gas detection instrumentation to cover the air gap below the elevated slab. A minimum of 8 gas detectors per tank shall be furnished. The gas detectors shall be wired to the junction boxes at the Battery Limits. TANK CONTRACTOR shall provide complete and comprehensive testing procedures for all equipment and systems provided. TANK CONTRACTOR shall develop as part of this Scope of Work the following information, as a minimum but without limitation: • ISA (Instrument Society of America) data sheets for a...
AutoNDA by SimpleDocs
Instrumentation/Control Systems. Test and install all equipment and materials, including those items supplied by PURCHASER in order to provide a complete and operating control and instrumentation system per this “Exhibit D.” • Install cable and complete all cable terminations between instruments and control panels/junction boxes within TANK CONTRACTOR’s battery limit. • Install instrument air pipe and tubing, valves, and tube fittings, as required. • All cables shall be supported in cable tray or in channels. • Inspect, calibrate and test all transmitting instruments and process switches. • Perform continuity loop checks for each instrument loop in coordination with and witnessed by PURCHASER. • TANK CONTRACTOR shall maintain all test and calibration documentation and turn over such documentation upon final acceptance of the Work. • Complete instrumentation, data acquisition, and communication interface units shall be configured and tested by TANK CONTRACTOR and witnessed and accepted by PURCHASER.

Related to Instrumentation/Control Systems

  • Systems The details of any systems work will be determined after a thorough business analysis. System's work will be billed on a time and material basis. Investors Bank provides an allowance of 10 systems hours for data extract set up and reporting extract set up. Additional hours will be billed on a time and material basis.

  • Information Systems Acquisition Development and Maintenance a. Client Data – Client Data will only be used by State Street for the purposes specified in this Agreement.

  • Compliance Control Services (1) Support reporting to regulatory bodies and support financial statement preparation by making the Fund's accounting records available to the Trust, the Securities and Exchange Commission (the “SEC”), and the independent accountants.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Measurement and Monitoring Tools As of the Effective date, Vendor and Prudential will mutually agree on the measurements and service level management procedures, pursuant to the governance procedures set forth in Attachment G and performance standards set forth in Attachment E-1 and E-2, to measure Vendor's performance of the Services against the applicable Service Levels. Such measurement and monitoring tools and procedures will (a) for Attachment E-1, be implemented upon the Effective Date; (b) for Attachment E-2, be implemented after successful completion of all testing and written acceptance by Prudential of the Transition Services set forth in Attachment B-1; (c) permit reporting at a level of detail sufficient to verify compliance with the Service Levels; and (d) be subject to audit by Prudential or its designee in accordance with the Agreement, except such audit will not include the installation of any audit software on Vendor's network.

  • Cash Management Systems On or prior to the Closing Date, Borrowers will establish and will maintain until the Termination Date, the cash management systems described in Annex C (the “Cash Management Systems”).

  • Review Systems The Asset Representations Reviewer will maintain and utilize an electronic case management system to manage the Tests and provide systematic control over each step in the Review process and ensure consistency and repeatability among the Tests.

  • ANALYSIS AND MONITORING The Custodian shall (a) provide the Fund (or its duly-authorized investment manager or investment adviser) with an analysis of the custody risks associated with maintaining assets with the Eligible Securities Depositories set forth on Schedule B hereto in accordance with section (a)(1)(i)(A) of Rule 17f-7, and (b) monitor such risks on a continuing basis, and promptly notify the Fund (or its duly-authorized investment manager or investment adviser) of any material change in such risks, in accordance with section (a)(1)(i)(B) of Rule 17f-7.

  • Technical Documentation Subject to the terms of this Agreement, BROCADE hereby grants to McDATA a nonexclusive, nontransferable, worldwide license to reproduce and use BROCADE's technical documentation provided to McDATA by BROCADE hereunder, solely for McDATA's internal purposes in connection with the manufacture, marketing and support of the McDATA Products into which the Products are incorporated as set forth herein. Modifications to such technical documentation by McDATA shall require BROCADE's prior written authorization, which authorization will not be unreasonably withheld.

  • Interfaces 1 2 wire i/f (towards PSTN) -------------------------------------------------------------------------------------------------------- 2 2 wire i/f (towards standard handset) -------------------------------------------------------------------------------------------------------- 2.2 FUNCTIONS -------------------------------------------------------------------------------------------------------- 1 Selective Call -------------------------------------------------------------------------------------------------------- 2 Conference Call (up to four participants) ----------------------------------------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------- 3 MANAGEMENT COMMUNICATION -------------------------------------------------------------------------------------------------------- 3.1 COMMUNICATION INTERFACES see OPTera Product Description SEC. 5.2.3 - Standard Communications Interfaces and SEC.7.3 - Management Communication -------------------------------------------------------------------------------------------------------- 1 F- Interface (RS 232) -------------------------------------------------------------------------------------------------------- 2 Q- interface as gateway to the EMS -------------------------------------------------------------------------------------------------------- 3 Qecc Routing (2 level IS-IS) -------------------------------------------------------------------------------------------------------- 4 Q I/F (Ethernet) -------------------------------------------------------------------------------------------------------- 5 Optical Supervisory Channel ----------------------------------------------------------------------------------------------------------------------------------- 6 OSC - wavelength IR IR IR see OPTera Product - bitrate Description SEC. 5.2.2 - optical span limit - Per Wavelength - transmission protocol Optical Service Channel and SEC.7.3 - Management Communication ----------------------------------------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------- 3.2 O & M INTERFACES ----------------------------------------------------------------------------------------------------------------------------------- 1 8 x Remote Control Inputs ----------------------------------------------------------------------------------------------------------------------------------- 2 Remote Control Outputs ----------------------------------------------------------------------------------------------------------------------------------- 3 Card LED support ----------------------------------------------------------------------------------------------------------------------------------- 4 Subrack LED support ----------------------------------------------------------------------------------------------------------------------------------- 5 Rack Alarm support ----------------------------------------------------------------------------------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------------------

Time is Money Join Law Insider Premium to draft better contracts faster.