Common use of Insulation of Premises Clause in Contracts

Insulation of Premises. Seller and Purchaser hereby acknowledge pursuant to Section 460.16 of the Federal Trade Commission Regulations regarding labeling and advertising of home insulation, that the types, thicknesses and R-Values of insulation presently anticipated to be installed in the Unit at the time of Closing shall be as set forth below: Insulation Disclosure Table Area Insulated Exterior Insulation Cavity Insulation Wall R- Value Exterior Wall Fiber Cement Wall 4" Polyiso Isulation (R-25) 6" Mineral Wool Batt (R-24) R-49 Thermomass Wall 3" Isomass Polyiso (R-19.5) 3" Fiberglass Batt R-22 Redicor Exterior Concrete Wall 3" XPS (R-15) N/A R-18 C.I.P. Concrete Wall 3" XPS (R-15) 3" Fiberglass Batt R-28 Wood-Pattern Aluminum Siding 4" Polyiso Isulation (R-25) 6" Mineral Wool Batt (R-24) R-49 Glazing Glazing - Fixed Triple Paned, Thermally Broken, Low-E coated, Solar Heat Gain Coefficient: 0.15, North Visible Light Transmittance: 0.6, South/East/West Visible Light Transmittance: 0.3 R-10, U- 0.10 Glazing - Operable R-7, U- 0.14 Glazing - Swing Door R-6.25, U- 0.16 Exterior Roof / Floor Unit Roof 6" Polyiso (R-36) 9.5" Mineral Wool Batt (R-38) X-00 Xxxxxxx Xxx, Xxxxxxx Xxxxx Xxxxx X/X 9.5" Mineral Wool Batt (R-38) R-40 LL Lid, Parking Floor 2.5" Closed-Cell Spray Foam (R-18.5) N/A R-22 LL EHU Lid, Parking Floor 2.5" Closed-Cell Spray Foam (R-18.5) 6" Mineral Wool Batt (R-24) R-46 Interior Assemblies Unit Floor / Ceiling N/A 6" Fiberglass Batt R-24.8 Unit Demising Wall N/A 7" Fiberglass Batt w/ 1"Air Gap R-25.1 Unit Corridor Wall N/A 6" Fiberglass Batt R-19.78 The "R-Value" indicates the resistance of insulation to heat flow. The higher the R-Value, the greater the insulating power. Seller has not made its own independent determination of the R-Value data provided to Seller by the insulation manufacturer.

Appears in 3 contracts

Samples: Purchase and Sale Agreement, Purchase and Sale Agreement, Purchase and Sale Agreement

AutoNDA by SimpleDocs

Insulation of Premises. Seller and Purchaser hereby acknowledge pursuant to Section 460.16 of the Federal Trade Commission Regulations regarding labeling and advertising of home insulation, that the types, thicknesses and R-Values of insulation presently anticipated to be installed in the Unit at the time of Closing shall be as set forth below: Insulation Disclosure Table Area Insulated Exterior Insulation Cavity Insulation Wall Value R- Value Exterior Wall Fiber Cement Wall 4" Polyiso Isulation (R-25) 6" Mineral Wool Batt (R-24) R-49 Thermomass Wall 3" Isomass Polyiso (R-19.5) 3" Fiberglass Batt R-22 Redicor Exterior Concrete Wall 3" XPS (R-15) N/A R-18 C.I.P. Concrete Wall 3" XPS (R-15) 3" Fiberglass Batt R-28 Wood-Pattern Aluminum Siding 4" Polyiso Isulation (R-25) 6" Mineral Wool Batt (R-24) R-49 Glazing Glazing - Fixed Triple Paned, Thermally Broken, Low-E coated, Solar Heat Gain R-10, U- Coefficient: 0.15, North Visible Light Transmittance: 0.6, 0.10 Glazing - Operable South/East/West Visible Light Transmittance: 0.3 R-10, U- 0.10 Glazing - Operable R-7, U- 0.14 Glazing - Swing Door R-6.25, U- 0.16 Exterior Roof / Floor Unit Roof 6" Polyiso (R-36) 9.5" Mineral Wool Batt (R-38) X-00 Xxxxxxx Xxx, Xxxxxxx Xxxxx Xxxxx X/X 9.5" Mineral Wool Batt (R-38) R-40 LL Lid, Parking Floor 2.5" Closed-Cell Spray Foam (R-18.5) N/A R-22 LL EHU Lid, Parking Floor 2.5" Closed-Cell Spray Foam (R-18.5) 6" Mineral Wool Batt (R-24) R-46 Interior Assemblies Unit Floor / Ceiling N/A 6" Fiberglass Batt R-24.8 Unit Demising Wall N/A 7" Fiberglass Batt w/ 1"Air Gap R-25.1 Unit Corridor Wall N/A 6" Fiberglass Batt R-19.78 The "R-Value" indicates the resistance of insulation to heat flow. The higher the R-Value, the greater the insulating power. Seller has not made its own independent determination of the R-Value data provided to Seller by the insulation manufacturer.

Appears in 1 contract

Samples: Purchase and Sale Agreement

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.