Lighting Plans Required Sample Clauses
Lighting Plans Required. A lighting plan shall be submitted with any building permit application in which outdoor lighting is proposed or required, except when all proposed lighting is provided by fixtures of nine hundred lumens or less, and except for a single detached dwelling unit on an individual lot. The lighting plan shall include:
(1) A site plan showing the location of all buildings and building heights, parking, and pedestrian areas on the lot or parcel;
(2) The location and description including mature height of existing and proposed trees and the location of light fixtures on adjacent properties or the street right-of-way within ten feet of the subject property;
(3) The location and height above grade of all proposed and existing light fixtures on the subject property;
(4) The type, initial lumen rating, color rendering index, and wattage of each lamp source;
(5) The general style of the light fixture such as cutoff, lantern, coach light, globe, and a copy of the manufacturer's catalog information sheet and IESNA photometric distribution type, including any shielding information such as house side ▇▇▇▇▇▇▇, internal, and/or external ▇▇▇▇▇▇▇;
(6) Control descriptions including type of controls (timer, motion sensor, time clock, etc.), the light fixtures to be controlled by each type, and control schedule when required;
(7) Aiming angles and diagrams for sports lighting fixtures; and
(8) A light calculation which shows the maximum light levels on a grid not to exceed ten feet by ten feet across the entire site and a minimum of ten feet beyond the lot or parcel property line. The grid shall also indicate maximum to minimum uniformities for each specific use area such as parking and circulation areas, pedestrian areas, and other common public areas.