Location of test samples. in the mist cabinet 2.1. Samples, except retractors, shall be supported or suspended between 15° and 30° from the vertical and preferably parallel to the principal direction of horizontal flow of mist through the chamber, based upon the dominant surface being tested. 2.2. Retractors shall be supported or suspended so that the axes of the reel for storing the strap shall be perpendicular to the principal direction of horizontal flow of mist through the chamber. The strap opening in the retractor shall also be facing in this principal direction. 2.3. Each sample shall be so placed as to permit free settling of mist on all samples. 2.4. Each sample shall be so placed as to prevent salt solution from one sample dripping on to any other sample.