Main Runner Channels Sample Clauses

Main Runner Channels. Furnish 1-1/2 inch x 16 gauge cold rolled steel channels weighing 475 lbs. per 1000 lin. ft., galvanized finish.
AutoNDA by SimpleDocs

Related to Main Runner Channels

  • Games The Private Party shall not be entitled to introduce any arcade type amusement or gaming machines into the Restaurant Facility without the prior written approval of SANParks.

  • DHS Seal, Logo, and Flags The Contractor shall not use the Department of Homeland Security (DHS) seal(s), logos, crests, or reproductions of flags or likeness of DHS agency officials without specific FEMA pre-approval.

  • MIDDLE SCHOOLS 1. Where there are no negotiated provisions concerning the implementation or operation of a middle school program, this article shall govern the implementation or operation of a middle school program in a school district. 2. Should the employer seek to establish a middle school program in one or more schools in a district, the employer and the local shall meet, no later than ten (10) working days from a decision of the employer to implement a middle school program, in order to negotiate any alternate or additional provisions to the Collective Agreement which are necessary to accommodate the intended middle school program. 3. In the absence of any other agreement with respect to the instructional day and preparation time, the provisions of the Collective Agreement with regard to secondary schools shall apply to middle schools. 4. If the employer and the local are unable to agree on what, if any, alternate or additional provisions of the collective agreement are necessary to accommodate the intended middle school program(s), either party may refer the matter(s) in dispute to expedited arbitration for final and binding resolution pursuant to Article D.5.5 below. a. The jurisdiction of the arbitrator shall be limited to the determination of alternate or additional provisions necessary to accommodate the intended middle school program(s). b. In the event the arbitration is not concluded prior to the implementation of the middle school program, the arbitrator will have remedial authority to make appropriate retroactive modifications and adjustments to the agreement. c. The arbitration shall convene within thirty (30) working days of referral to arbitration in accordance with the following: i. Within ten (10) working days of the matter being referred to arbitration, the parties shall identify all issues in dispute; ii. Within a further five (5) working days, there shall be a complete disclosure of particulars and documents; iii. Within a further five (5) working days, the parties shall exchange initial written submissions; iv. The hearing shall commence within a further ten (10) working days; and v. The arbitrator shall render a final and binding decision within fifteen (15) working days of the arbitration concluding. 6. Where a middle school program has been established on or prior to ratification of the 2006-2011 Provincial Collective Agreement, the existing provisions shall be retained unless the parties mutually agree that they should be amended.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • External Hosting Facilities DST shall implement controls, consistent with applicable prevailing industry practices and standards, regarding the collection, use, storage and/or disclosure of Fund Data by an external hosting provider.

  • COVID-19 Vaccine Passports Pursuant to Texas Health and Safety Code, Section 161.0085(c), Contractor certifies that it does not require its customers to provide any documentation certifying the customer’s COVID-19 vaccination or post-transmission recovery on entry to, to gain access to, or to receive service from the Contractor’s business. Contractor acknowledges that such a vaccine or recovery requirement would make Contractor ineligible for a state-funded contract.

  • Placement of DNS probes Probes for measuring DNS parameters shall be placed as near as possible to the DNS resolvers on the networks with the most users across the different geographic regions; care shall be taken not to deploy probes behind high propagation-­‐delay links, such as satellite links.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Trunk Group Connections and Ordering 5.2.1 For both One-Way and Two-Way Interconnection Trunks, if Onvoy wishes to use a technically feasible interface other than a DS1 or a DS3 facility at the POI, the Parties shall negotiate reasonable terms and conditions (including, without limitation, rates and implementation timeframes) for such arrangement; and, if the Parties cannot agree to such terms and conditions (including, without limitation, rates and implementation timeframes), either Party may utilize the Agreement’s dispute resolution procedures. 5.2.2 When One-Way or Two-Way Interconnection Trunks are provisioned using a DS3 interface facility, if Onvoy orders the multiplexed DS3 facilities to a Frontier Central Office that is not designated in the NECA 4 Tariff as the appropriate Intermediate Hub location (i.e., the Intermediate Hub location in the appropriate Tandem subtending area based on the LERG), and the provision of such facilities to the subject Central Office is technically feasible, the Parties shall negotiate in good faith reasonable terms and conditions (including, without limitation, rates and implementation timeframes) for such arrangement; and, if the Parties cannot agree to such terms and conditions (including, without limitation, rates and implementation timeframes), either Party may utilize the Agreement’s dispute resolution procedures. 5.2.3 Each Party will identify its Carrier Identification Code, a three or four digit numeric code obtained from Telcordia, to the other Party when ordering a trunk group. 5.2.4 For multi-frequency (MF) signaling each Party will out pulse ten (10) digits to the other Party, unless the Parties mutually agree otherwise. 5.2.5 Each Party will use commercially reasonable efforts to monitor trunk groups under its control and to augment those groups using generally accepted trunk- engineering standards so as to not exceed blocking objectives. Each Party agrees to use modular trunk-engineering techniques for trunks subject to this Attachment.

  • MPS LOGO/PUBLICITY No Contractor shall use the MPS Logo in its literature or issue a press release about the subject of this Contract without prior written notice to and written approval of MPS’s Executive Director of Communications & Outreach.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!