Meter and Density Factor Deviation. The determined meter and density factors shall be applied to the daily registered volume and mass for that measurement station until the next applicable correction is determined. If any test shows the meter or density factor is not in error more than 0.25%, such equipment will be considered as correct; but such equipment or correction factors will be properly adjusted at once to zero error. If any test shows the meter or densitometer factor then in use, are in error by more than 0.25% but less than 0.50%, it shall be the decision of the concerned field personnel as to the scope and corrective action taken towards the repair of the equipment, if any. Deviation of factor(s) greater than 0.50% will not be acceptable and Processor shall proceed with diligence to effect the required maintenance, repairs or replacement. If any test shows the meter or densitometer is not in error more than a total of one-quarter of one percent (0.25%), previous readings of such equipment will be considered as correct; but such equipment or correction factors will be properly adjusted at once to zero error.
Appears in 3 contracts
Samples: Natural Gas Liquids Exchange Agreement (Eagle Rock Energy Partners, L.P.), Natural Gas Liquids Exchange Agreement (Eagle Rock Energy Partners, L.P.), Natural Gas Liquids Exchange Agreement (Eagle Rock Energy Partners, L.P.)
Meter and Density Factor Deviation. The determined meter and density factors shall be applied to the daily registered volume and mass for that the measurement station until the next applicable correction is determined. If any test shows the meter or density factor is not in error more by less than 0.25.25%, such equipment will be considered as correct; but provided, however, such equipment or correction factors will be properly adjusted at once to zero error. If any test shows the meter or densitometer factor then in use, are use is in error by more than 0.25% .25%, but less than 0.50.50%, it shall be the decision of the concerned field personnel parties as to the scope and corrective action taken towards the repair of the equipmenttaken, if any. Deviation of factor(s) greater than 0.50.50% under similar conditions will not be acceptable and Processor Buyer or its designee shall proceed with diligence to effect the required maintenance, repairs or replacement. If any test shows the meter or densitometer measurement equipment is not in error more by less than a total of one-quarter half of one percent (0.25.50%), previous readings of such equipment will be considered as correct; but provided, however, such equipment or correction factors will be properly adjusted at once to zero error.
Appears in 2 contracts
Samples: Natural Gas Liquids Purchase Agreement, Natural Gas Liquids Purchase Agreement (Markwest Energy Partners L P)