The 'Meter software' clause defines the terms under which software is used to monitor, measure, or track usage of a particular service or product. Typically, this clause outlines the rights and obligations regarding the installation, access, and operation of metering software, specifying who is responsible for maintaining the software and how data collected will be used. Its core practical function is to ensure accurate measurement of usage for billing, compliance, or performance purposes, thereby preventing disputes and ensuring transparency between parties.
Meter software. 6.1. The meter’s software shall be supplied with the meters with open license and security keys and programing cable for at least 15 users, this software should be user-friendly including all controllable parameterization features such as multi-level of security for down loading and up loading the data USB key is required . The software module could be upgraded or modified upon to IDECO requests without extra charges while (IDECO) owns all software management properties. The software shall be submitted with very detailed user manual along with the sample which should be submitted with the offer this software should have individual user accounts and it should communicate with the meters using IR and also remotely communication with free license for the all supplied meter quantity. (The vendor should make any required modification on the software within 24 months after delivery with maximum 30 days to complete any requested modification after IDECO send it to his official address (email or fax)).
6.2. The meter software is preferred to have the ability of programing number of meters connected to the system remotely at once, monitor and configured at same time.
6.3. The meter shall be able to store all events happened with their time stamp in the log book such as (power up, power down, tampering events, over voltage... etc.). This event parameter should be programmable for the value and the duration (for some event like over voltage or sag …. etc.) which should be up to 60 minutes interval.
6.4. The features in the Special Requirements are required.
6.5. The vendor shall provide IDECO with any needed support to program IDECO HHU to control the meter. Upon to IDECO request with the same modification condition in point 6.1.
6.6. The software shall be compatible to connect to the meters remotely through GPRS and RF the tenderer should supply all the required to run the software using IDECO servers to support all the supplied quantity of meters.
6.7. The software and the meter shall have a log, where it shall store the user information, meter number, date & time, and the type of modification accrued.
Meter software. Item Approved Deviation 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
Meter software. 5.1. The meter’s software shall be supplied with the meters with full lifetime open license and should be user-friendly including all controllable parameterization features such as multi-level of security for down loading and up loading the data.
5.2. The software module preferred to be upgraded or modified upon to IDECO requests without extra charges while (IDECO) owns all software management properties.
5.3. The software shall be submitted with very detailed user manual along with the sample which should be submitted with the offer this software should have individual user accounts and it should communicate with the meters using IR
5.4. The meter software is preferred to have the ability of programing number of meters connected to the system remotely at once, monitor and configured at same time.
5.5. The meter shall be able to store all events happened with their time stamp in the log book such as (power up, power down, tampering events, over voltage... etc.). This event parameter should be programmable for the value and the duration (for some event like over voltage or sag …. etc.) which should be up to 60 minutes interval.
5.6. The vendor shall provide IDECO with any needed support to program IDECO HHU to control the meter upon to IDECO request with the same modification condition in point 6.1.
5.7. If the vendor didn’t provide AMI service with the meters The PC software must has the capability to connect be to the meters remotely through GPRS, and the tenderer should supply all the required to run the software using IDECO servers to support all the supplied quantity of meters , if the PC software didn’t support this feature the vendor should provide other remote solution
5.8. The meter firmware preferred to be upgrade remotely with all required security stages
Meter software. The meter’s software shall be supplied with the meters with open license and security keys and programing cable for at least 30 users, this software should be user-friendly including all controllable parameterization features such as multi-level of security for down loading and up loading .
Meter software. 6.1. The meter’s software shall be supplied with the meters with open license and security keys and programing cable for at least 15 users, this software should be user-friendly including all controllable parameterization features such as multi-level of security for down loading and up loading the data USB key is required . The software module could be upgraded or modified upon to IDECO requests without extra charges while (IDECO) owns all software management properties. The software shall be submitted with very detailed user manual along with the sample which should be submitted with the offer this software should have individual user accounts and it should communicate with the meters using IR and also remotely communication with free license for the all supplied meter quantity. (The vendor should make any required modification on the software within 24 months after delivery with maximum 30 days to complete any requested modification after IDECO send it to his official address (email or fax)).
6.2. The meter shall be able to store all events happened with their time stamp in the log book such as (power up, power down, tampering events, over voltage... etc.). This event parameter should be programmable for the value and the duration (for some event like over voltage or sag …. etc.) which should be up to 60 minutes interval.
6.3. The software features in the Special Requirements are required.
6.4. The software shall be compatible to connect to the meters remotely through cellular, and the tenderer should supply all the required to run the software using IDECO servers to support all the supplied quantity of meters.
6.5. Its highly prefferd to have an independent security level in the software (with a separate password) regarding the CT and VT ratio. The default password shall be hard to remember and the manufacturer should provide IDECO with the password upon delivery.
6.6. The software and the meter are preferred to have a log, where it shall store the user, meter number, date & time, and the type of modification accrued.
Meter software. Item Approved Deviation 6.1.1 6.1.2 6.1.3 6.1.4 6.1.5 6.1.6 6.2.1 6.2.2
Meter software. 6.1. The meter’s software shall be supplied with the meters with open license and security keys and programing cable for at least 15 users, this software should be user-friendly including all controllable parameterization features such as multi-level of security for down loading and up loading the data USB key is required . The software module could be upgraded or modified upon to IDECO requests without extra charges while (IDECO) owns all software management properties. The software shall be submitted with very detailed user manual along with the sample which should be submitted with the offer this software should have individual user accounts and it should communicate with the meters using IR and also remotely communication with free license for the all supplied meter quantity. (The vendor should make any required modification on the software within 24 months after delivery with maximum 30 days to complete any requested modification after IDECO send it to his official address (email or fax)).
6.2. The meter shall be able to store all events happened with their time stamp in the log book such as (power up, power down, tampering events, over voltage... etc.). This event parameter should be programmable for the value and the duration (for some event like over voltage or sag …. etc.) which should be up to 60 minutes interval.
6.3. The software features in the Special Requirements are required.
6.4. The software shall be compatible to connect to the meters remotely through cellular, and the tenderer should supply all the required to run the software using IDECO servers to support all the supplied quantity of meters.
6.5. Its highly prefferd to have an independent security level in the software (with a separate password) regarding the CT and VT ratio. The default password shall be hard to remember and the manufacturer should provide IDECO with the password upon delivery.
6.6. The software and the meter are preferred to have a log, where it shall store the user, meter number, date & time, and the type of modification accrued.