Method of testing Sample Clauses

Method of testing. The emission of ESA representative of its type shall be tested by the method(s) according to ISO 7637-2, as described in Annex 10 for the levels given in Table 17. Table 17 Maximum allowed pulse amplitude Maximum allowed pulse amplitude for Positive +75 V +150 V Negative –100 V –450 V 7.18. Specifications concerning immunity of ESAs to electromagnetic radiation
AutoNDA by SimpleDocs
Method of testing. The immunity of ESA representative of this type shall be tested by the method(s) according to ISO 7637-2 as described in Annex 10 with the test levels given in Table 2. Table 2 1 III C D 2a III B D 2b III C D 3a/3b III A D
Method of testing. The immunity to electromagnetic radiation of the vehicle representative of its type shall be tested by the method described in Annex 6.
Method of testing. 7.9.1.1. The immunity to surge conducted along AC/DC power lines of the vehicle representative of its type shall be tested by the method described in Annex 16.
Method of testing. Chemical composition testing for sodium chloride shall conform to the rapid method of testing given in Appendix A1 of AASHTO M-143-86. A second method of rapid analysis could be the use of Gran’s plot titration method developed by Orion Research Incorporated. In case that the coarse salt sample is used 100.00 g sample is taken and dissolved in a 2-liter volumetric flask quantitatively. An aliquot of 5.00 ml or 2.00 ml of this solution is then pipetted out to the titrated according to either of these two methods. If controversy occurs, analysis shall be made in accordance with the method specified for “Salt” in the currentOfficial Methods of Analysis for the Association of Official Agricultural Chemists”.
Method of testing. Unless otherwise specified, the conditions and procedures of Annex 3 shall be used. For the purpose of this annex, one run per test condition is measured and evaluated.
AutoNDA by SimpleDocs
Method of testing. 7.8.1.1. The immunity to Electrical Fast Transient/Burst disturbances conducted along AC and DC power lines of the vehicle representative of its type shall be tested by the method described in Annex 15.
Method of testing. The immunity to Electrical Fast Transient/Burst disturbances conducted along AC and DC power lines of the ESA representative of its type shall be tested by the method described in Annex 21.
Method of testing. The immunity to surge conducted along AC / DC power lines of the ESA representative of its type shall be tested by the method described in Annex 22.