Optional DC Power Measurement. CLEC will order DC power to meet its needs with a twenty (20) amperes (amp) per feed minimum. If CLEC orders more than sixty (60) amps, Qwest typically terminates such feed on a power board. If CLEC orders sixty (60) amps or less, the power feed typically terminates at a battery distribution fuse board (BDFB). No power measurements are performed at a BDFB. Therefore, for sixty (60) amps or less, the power usage rate is based on CLEC ordered amps. For power feeds of greater than sixty (60) amps terminated at the power board, Qwest will measure usage on a semi-annual basis if CLEC orders Optional DC Power Measurement. Qwest will also take a reading within thirty (30) Days of a written request by CLEC. Qwest will perform a maximum of four (4) readings per year for a particular Collocation site. If the initial measurement is zero, CLEC must notify Qwest when its equipment is in place and allow Qwest an additional reading to measure power. Based on these readings, if CLEC is utilizing less than the ordered amount of power, Qwest will reduce the monthly usage rate to CLEC's actual use based on the reading from the date of CLEC’s measuring request on a going forward basis until the next reading. If CLEC is utilizing more than the ordered amount, Qwest will increase the monthly usage rate to the CLEC's actual use. Once Qwest receives a CLEC measuring request, it will xxxx the actual power usage rate based on the reading from the date of the CLEC’s measuring request, on a going forward basis, until the next reading. Until the routine semi-annual reading or until such time that Qwest makes a reading based on a written request, Qwest will xxxx XXXX based on the amount of power ordered.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Optional DC Power Measurement. CLEC will order DC power to meet its needs with a twenty (20) amperes (amp) per feed minimum. If CLEC orders more than sixty (60) amps, Qwest typically terminates such feed on a power board. If CLEC orders sixty (60) amps or less, the power feed typically terminates at a battery distribution fuse board (BDFB). No power measurements are performed at a BDFB. Therefore, for sixty (60) amps or less, the power usage rate is based on CLEC ordered amps. For power feeds of greater than sixty (60) amps terminated at the power board, Qwest will measure usage on a semi-annual basis if CLEC orders Optional DC Power Measurement. Qwest will also take a reading within thirty (30) Days of a written request by CLEC. Qwest will perform a maximum of four (4) readings per year for a particular Collocation site. If the initial measurement is zero, CLEC must notify Qwest when its equipment is in place and allow Qwest an additional reading to measure power. Until the routine semi-annual reading or until such time that Qwest makes a reading based on a written request, Qwest will xxxx XXXX based on the amount of power ordered. Based on these readings, if CLEC is utilizing less than the ordered amount of power, Qwest will reduce the monthly usage rate to CLEC's actual use based on the reading from the date of CLEC’s measuring request on a going forward basis until the next reading. If CLEC is utilizing more than the ordered amount, Qwest will increase the monthly usage rate to the CLEC's ’s actual use. Once Qwest receives a CLEC measuring request, it will xxxx the actual power usage rate based on the reading from the date of the CLEC’s measuring request, on a going forward basis, until the next reading. Until the routine semi-annual reading or until such time that Qwest makes a reading based on a written request, Qwest will xxxx XXXX based on the amount of power ordered.
Appears in 1 contract
Samples: Interconnection Agreement
Optional DC Power Measurement. CLEC will order DC power to meet its needs with a twenty (20) amperes (amp) per feed minimum. If CLEC orders more than sixty (60) amps, Qwest typically terminates such feed on a power board. If CLEC orders sixty (60) amps or less, the power feed typically terminates at a battery distribution fuse board (BDFB). No power measurements are performed at a BDFB. Therefore, for sixty (60) amps or less, the power usage rate is based on CLEC ordered amps. For power feeds of greater than sixty (60) amps terminated at the power board, Qwest will measure usage on a semi-annual basis if CLEC orders Optional DC Power Measurement. Qwest will also take a reading within thirty (30) Days of a written request by CLECXXXX. Qwest will perform a maximum of four (4) readings per year for a particular Collocation site. If the initial measurement is zero, CLEC must notify Qwest when its equipment is in place and allow Qwest an additional reading to measure power. Based on these readings, if CLEC is utilizing less than the ordered amount of power, Qwest will reduce the monthly usage rate to CLEC's actual use based on the reading from the date of CLEC’s measuring request on a going forward basis until the next reading. If CLEC is utilizing more than the ordered amount, Qwest will increase the monthly usage rate to the CLEC's actual use. Once Qwest receives a CLEC measuring request, it will xxxx bill the actual power usage rate based on the reading from the date of the CLEC’s measuring request, on a going forward basis, until the next reading. Until the routine semi-annual reading or until such time that Qwest makes a reading based on a written request, Qwest will xxxx XXXX based on the amount of power ordered.
Appears in 1 contract
Samples: Interconnection Agreement