Passenger Elevators. Compliance with the requirements of the ADAAG and Michigan Building Code will provide the minimum determination for provision of a passenger elevator, unless specified in the Request for Proposal (RFP), Program, or State Agency Supplementary Standards. 1. For typical 2‐stop application provide a hole‐less hydraulic passenger elevator system, 2,500 pound capacity minimum with a finish clear cab size of not less than 6’‐8” x 4’‐3” with a minimum ceiling height of 7’‐11”. Cab speed shall not be less than 80 feet per minute. For facilities requiring more than 2 stops, or depending on building size and use, multiple elevators, larger elevator platform size, speed and weight capacity will be required. Elevator cabs are to have plastic laminate side walls, protective bumpers and skid‐resistant vinyl composition tile floor surface. Furnish removable protective pads.
Appears in 6 contracts
Samples: Lease Agreement, Lease Agreement, Lease Agreement
Passenger Elevators. Compliance with the requirements of the ADAAG and Michigan Building Code will provide the minimum determination for provision of a passenger elevator, unless specified in the Request for Proposal (RFP), Program, or State Agency Supplementary StandardsProject Component Checklist.
1. For typical 2‐stop 2-stop application provide a hole‐less hole-less hydraulic passenger elevator system, 2,500 pound capacity minimum with a finish clear cab size of not less than 6’‐86’-8” x 4’‐34’-3” with a minimum ceiling height of 7’‐117’-11”. Cab speed shall not be less than 80 feet per minute. For facilities requiring more than 2 stops, or depending on building size and use, multiple elevators, larger elevator platform size, speed and weight capacity will be required. Elevator cabs are to have plastic laminate side walls, protective bumpers and skid‐resistant skid-resistant vinyl composition tile floor surface. Furnish removable protective pads.
Appears in 1 contract
Samples: Lease Agreement